artiq-zynq/src/gateware/zc706.py

693 lines
27 KiB
Python
Raw Normal View History

2020-04-11 17:39:16 +08:00
#!/usr/bin/env python
import argparse
from operator import itemgetter
2020-04-11 17:39:16 +08:00
from migen import *
from migen.build.generic_platform import *
from migen.genlib.resetsync import AsyncResetSynchronizer
from migen.genlib.cdc import MultiReg
2020-04-11 17:39:16 +08:00
from migen_axi.integration.soc_core import SoCCore
from migen_axi.platforms import zc706
from misoc.interconnect.csr import *
2020-04-11 17:39:16 +08:00
from misoc.integration import cpu_interface
from misoc.cores import gpio
2020-04-11 17:39:16 +08:00
2020-05-07 17:05:00 +08:00
from artiq.gateware import rtio, nist_clock, nist_qc2
from artiq.gateware.rtio.phy import ttl_simple, ttl_serdes_7series, dds, spi2
from artiq.gateware.rtio.xilinx_clocking import RTIOClockMultiplier, fix_serdes_timing_path
from artiq.gateware.drtio.transceiver import gtx_7series
from artiq.gateware.drtio.siphaser import SiPhaser7Series
from artiq.gateware.drtio.rx_synchronizer import XilinxRXSynchronizer
from artiq.gateware.drtio import *
2020-04-11 17:39:16 +08:00
2020-07-13 10:37:17 +08:00
import dma
2020-07-15 23:06:34 +08:00
import analyzer
import acpki
import drtio_aux_controller
2020-07-13 10:37:17 +08:00
class RTIOCRG(Module, AutoCSR):
def __init__(self, platform, rtio_internal_clk):
self.clock_sel = CSRStorage()
self.pll_reset = CSRStorage(reset=1)
self.pll_locked = CSRStatus()
self.clock_domains.cd_rtio = ClockDomain()
self.clock_domains.cd_rtiox4 = ClockDomain(reset_less=True)
rtio_external_clk = Signal()
user_sma_clock = platform.request("user_sma_clock")
platform.add_period_constraint(user_sma_clock.p, 8.0)
self.specials += Instance("IBUFDS",
i_I=user_sma_clock.p, i_IB=user_sma_clock.n,
o_O=rtio_external_clk)
pll_locked = Signal()
rtio_clk = Signal()
rtiox4_clk = Signal()
self.specials += [
Instance("PLLE2_ADV",
p_STARTUP_WAIT="FALSE", o_LOCKED=pll_locked,
p_REF_JITTER1=0.01,
p_CLKIN1_PERIOD=8.0, p_CLKIN2_PERIOD=8.0,
i_CLKIN1=rtio_internal_clk, i_CLKIN2=rtio_external_clk,
# Warning: CLKINSEL=0 means CLKIN2 is selected
i_CLKINSEL=~self.clock_sel.storage,
# VCO @ 1GHz when using 125MHz input
p_CLKFBOUT_MULT=8, p_DIVCLK_DIVIDE=1,
i_CLKFBIN=self.cd_rtio.clk,
i_RST=self.pll_reset.storage,
o_CLKFBOUT=rtio_clk,
p_CLKOUT0_DIVIDE=2, p_CLKOUT0_PHASE=0.0,
o_CLKOUT0=rtiox4_clk),
Instance("BUFG", i_I=rtio_clk, o_O=self.cd_rtio.clk),
Instance("BUFG", i_I=rtiox4_clk, o_O=self.cd_rtiox4.clk),
AsyncResetSynchronizer(self.cd_rtio, ~pll_locked),
MultiReg(pll_locked, self.pll_locked.status)
]
# The NIST backplanes require setting VADJ to 3.3V by reprogramming the power supply.
# This also changes the I/O standard for some on-board LEDs.
leds_fmc33 = [
("user_led_33", 0, Pins("Y21"), IOStandard("LVCMOS33")),
("user_led_33", 1, Pins("G2"), IOStandard("LVCMOS15")),
("user_led_33", 2, Pins("W21"), IOStandard("LVCMOS33")),
("user_led_33", 3, Pins("A17"), IOStandard("LVCMOS15")),
]
# same deal as with LEDs - changed I/O standard.
si5324_fmc33 = [
("si5324_33", 0,
Subsignal("rst_n", Pins("W23"), IOStandard("LVCMOS33")),
Subsignal("int", Pins("AJ25"), IOStandard("LVCMOS33"))
),
]
pmod1_33 = [
("pmod1_33", 0, Pins("AJ21"), IOStandard("LVCMOS33")),
("pmod1_33", 1, Pins("AK21"), IOStandard("LVCMOS33")),
("pmod1_33", 2, Pins("AB21"), IOStandard("LVCMOS33")),
("pmod1_33", 3, Pins("AB16"), IOStandard("LVCMOS33")),
# rest removed for use with dummy spi
]
_ams101_dac = [
("ams101_dac", 0,
Subsignal("ldac", Pins("XADC:GPIO0")),
Subsignal("clk", Pins("XADC:GPIO1")),
Subsignal("mosi", Pins("XADC:GPIO2")),
Subsignal("cs_n", Pins("XADC:GPIO3")),
IOStandard("LVCMOS15")
)
]
2021-10-14 16:37:13 +08:00
_pmod_spi = [
("pmod_spi", 0,
# PMOD_1 4-7 pins, same bank as sfp_tx_disable or user_sma_clock
Subsignal("miso", Pins("Y20"), IOStandard("LVCMOS25")),
Subsignal("clk", Pins("AA20"), IOStandard("LVCMOS25")),
Subsignal("mosi", Pins("AC18"), IOStandard("LVCMOS25")),
Subsignal("cs_n", Pins("AC19"), IOStandard("LVCMOS25")),
IOStandard("LVCMOS25")
)
]
def prepare_zc706_platform(platform):
platform.toolchain.bitstream_commands.extend([
"set_property BITSTREAM.GENERAL.COMPRESS True [current_design]",
])
platform.add_platform_command("create_clock -name clk_fpga_0 -period 8 [get_pins \"PS7/FCLKCLK[0]\"]")
platform.add_platform_command("set_input_jitter clk_fpga_0 0.24")
2020-04-11 17:39:16 +08:00
class ZC706(SoCCore):
def __init__(self, acpki=False):
self.acpki = acpki
self.rustc_cfg = dict()
2020-04-11 17:39:16 +08:00
platform = zc706.Platform()
prepare_zc706_platform(platform)
ident = self.__class__.__name__
if self.acpki:
ident = "acpki_" + ident
SoCCore.__init__(self, platform=platform, csr_data_width=32, ident=ident)
2020-04-11 17:39:16 +08:00
self.submodules.rtio_crg = RTIOCRG(self.platform, self.ps7.cd_sys.clk)
self.csr_devices.append("rtio_crg")
self.rustc_cfg["has_rtio_crg_clock_sel"] = None
self.platform.add_period_constraint(self.rtio_crg.cd_rtio.clk, 8.)
self.platform.add_false_path_constraints(
self.ps7.cd_sys.clk,
self.rtio_crg.cd_rtio.clk)
2020-04-11 17:39:16 +08:00
def add_rtio(self, rtio_channels):
self.submodules.rtio_tsc = rtio.TSC("async", glbl_fine_ts_width=3)
self.submodules.rtio_core = rtio.Core(self.rtio_tsc, rtio_channels)
self.csr_devices.append("rtio_core")
if self.acpki:
self.rustc_cfg["ki_impl"] = "acp"
self.submodules.rtio = acpki.KernelInitiator(self.rtio_tsc,
bus=self.ps7.s_axi_acp,
user=self.ps7.s_axi_acp_user,
evento=self.ps7.event.o)
self.csr_devices.append("rtio")
2020-08-04 13:26:45 +08:00
else:
self.rustc_cfg["ki_impl"] = "csr"
self.submodules.rtio = rtio.KernelInitiator(self.rtio_tsc, now64=True)
self.csr_devices.append("rtio")
2020-07-13 10:37:17 +08:00
self.submodules.rtio_dma = dma.DMA(self.ps7.s_axi_hp0)
self.csr_devices.append("rtio_dma")
2020-04-11 17:39:16 +08:00
2020-07-13 10:37:17 +08:00
self.submodules.cri_con = rtio.CRIInterconnectShared(
[self.rtio.cri, self.rtio_dma.cri],
[self.rtio_core.cri])
self.csr_devices.append("cri_con")
2020-04-11 17:39:16 +08:00
2020-04-24 13:36:36 +08:00
self.submodules.rtio_moninj = rtio.MonInj(rtio_channels)
self.csr_devices.append("rtio_moninj")
2020-07-15 23:06:34 +08:00
self.submodules.rtio_analyzer = analyzer.Analyzer(self.rtio_tsc, self.rtio_core.cri,
self.ps7.s_axi_hp1)
self.csr_devices.append("rtio_analyzer")
2020-04-11 17:39:16 +08:00
class _MasterBase(SoCCore):
def __init__(self, acpki=False):
self.acpki = acpki
self.rustc_cfg = dict()
platform = zc706.Platform()
prepare_zc706_platform(platform)
ident = self.__class__.__name__
if self.acpki:
ident = "acpki_" + ident
SoCCore.__init__(self, platform=platform, csr_data_width=32, ident=ident)
platform.add_extension(si5324_fmc33)
self.sys_clk_freq = 125e6
platform = self.platform
self.comb += platform.request("sfp_tx_disable_n").eq(1)
data_pads = [
platform.request("sfp"),
platform.request("user_sma_mgt")
]
# 1000BASE_BX10 Ethernet compatible, 125MHz RTIO clock
self.submodules.drtio_transceiver = gtx_7series.GTX(
clock_pads=platform.request("si5324_clkout"),
pads=data_pads,
sys_clk_freq=self.sys_clk_freq)
self.csr_devices.append("drtio_transceiver")
self.submodules.rtio_tsc = rtio.TSC("async", glbl_fine_ts_width=3)
drtio_csr_group = []
drtioaux_csr_group = []
drtioaux_memory_group = []
self.drtio_cri = []
for i in range(len(self.drtio_transceiver.channels)):
core_name = "drtio" + str(i)
coreaux_name = "drtioaux" + str(i)
memory_name = "drtioaux" + str(i) + "_mem"
drtio_csr_group.append(core_name)
drtioaux_csr_group.append(coreaux_name)
drtioaux_memory_group.append(memory_name)
cdr = ClockDomainsRenamer({"rtio_rx": "rtio_rx" + str(i)})
core = cdr(DRTIOMaster(
self.rtio_tsc, self.drtio_transceiver.channels[i]))
setattr(self.submodules, core_name, core)
self.drtio_cri.append(core.cri)
self.csr_devices.append(core_name)
coreaux = cdr(drtio_aux_controller.DRTIOAuxControllerBare(core.link_layer))
setattr(self.submodules, coreaux_name, coreaux)
self.csr_devices.append(coreaux_name)
mem_size = coreaux.get_mem_size()
memory_address = self.axi2csr.register_port(coreaux.get_tx_port(), mem_size)
self.axi2csr.register_port(coreaux.get_rx_port(), mem_size)
self.add_memory_region(memory_name, self.mem_map["csr"] + memory_address, mem_size * 2)
self.rustc_cfg["has_drtio"] = None
self.rustc_cfg["has_drtio_routing"] = None
self.add_csr_group("drtio", drtio_csr_group)
self.add_csr_group("drtioaux", drtioaux_csr_group)
self.add_memory_group("drtioaux_mem", drtioaux_memory_group)
self.rustc_cfg["RTIO_FREQUENCY"] = str(self.drtio_transceiver.rtio_clk_freq/1e6)
self.submodules.si5324_rst_n = gpio.GPIOOut(platform.request("si5324_33").rst_n)
self.csr_devices.append("si5324_rst_n")
self.rustc_cfg["has_si5324"] = None
self.rustc_cfg["si5324_as_synthesizer"] = None
rtio_clk_period = 1e9/self.drtio_transceiver.rtio_clk_freq
# Constrain TX & RX timing for the first transceiver channel
# (First channel acts as master for phase alignment for all channels' TX)
gtx0 = self.drtio_transceiver.gtxs[0]
platform.add_period_constraint(gtx0.txoutclk, rtio_clk_period)
platform.add_period_constraint(gtx0.rxoutclk, rtio_clk_period)
platform.add_false_path_constraints(
self.ps7.cd_sys.clk,
gtx0.txoutclk, gtx0.rxoutclk)
# Constrain RX timing for the each transceiver channel
# (Each channel performs single-lane phase alignment for RX)
for gtx in self.drtio_transceiver.gtxs[1:]:
platform.add_period_constraint(gtx.rxoutclk, rtio_clk_period)
platform.add_false_path_constraints(
self.ps7.cd_sys.clk, gtx0.txoutclk, gtx.rxoutclk)
self.submodules.rtio_crg = RTIOClockMultiplier(self.sys_clk_freq)
self.csr_devices.append("rtio_crg")
fix_serdes_timing_path(self.platform)
def add_rtio(self, rtio_channels):
self.submodules.rtio_tsc = rtio.TSC("async", glbl_fine_ts_width=3)
self.submodules.rtio_core = rtio.Core(self.rtio_tsc, rtio_channels)
self.csr_devices.append("rtio_core")
if self.acpki:
self.rustc_cfg["ki_impl"] = "acp"
self.submodules.rtio = acpki.KernelInitiator(self.rtio_tsc,
bus=self.ps7.s_axi_acp,
user=self.ps7.s_axi_acp_user,
evento=self.ps7.event.o)
self.csr_devices.append("rtio")
else:
self.rustc_cfg["ki_impl"] = "csr"
self.submodules.rtio = rtio.KernelInitiator(self.rtio_tsc, now64=True)
self.csr_devices.append("rtio")
self.submodules.rtio_dma = dma.DMA(self.ps7.s_axi_hp0)
self.csr_devices.append("rtio_dma")
self.submodules.local_io = SyncRTIO(self.rtio_tsc, rtio_channels)
self.submodules.cri_con = rtio.CRIInterconnectShared(
[self.rtio.cri, self.rtio_dma.cri],
[self.local_io.cri] + self.drtio_cri,
mode="sync", enable_routing=True)
self.csr_devices.append("cri_con")
self.submodules.rtio_moninj = rtio.MonInj(rtio_channels)
self.csr_devices.append("rtio_moninj")
self.submodules.rtio_analyzer = analyzer.Analyzer(self.rtio_tsc, self.rtio_core.cri,
self.ps7.s_axi_hp1)
self.csr_devices.append("rtio_analyzer")
self.submodules.routing_table = rtio.RoutingTableAccess(self.cri_con)
self.csr_devices.append("routing_table")
class _SatelliteBase(SoCCore):
def __init__(self, acpki=False):
self.acpki = acpki
self.rustc_cfg = dict()
platform = zc706.Platform()
prepare_zc706_platform(platform)
ident = self.__class__.__name__
if self.acpki:
ident = "acpki_" + ident
SoCCore.__init__(self, platform=platform, csr_data_width=32, ident=ident)
platform.add_extension(si5324_fmc33)
self.sys_clk_freq = 125e6
platform = self.platform
# SFP
self.comb += platform.request("sfp_tx_disable_n").eq(0)
data_pads = [
platform.request("sfp"),
platform.request("user_sma_mgt")
]
self.submodules.rtio_tsc = rtio.TSC("sync", glbl_fine_ts_width=3)
# 1000BASE_BX10 Ethernet compatible, 125MHz RTIO clock
self.submodules.drtio_transceiver = gtx_7series.GTX(
clock_pads=platform.request("si5324_clkout"),
pads=data_pads,
sys_clk_freq=self.sys_clk_freq)
self.csr_devices.append("drtio_transceiver")
drtioaux_csr_group = []
drtioaux_memory_group = []
drtiorep_csr_group = []
self.drtio_cri = []
for i in range(len(self.drtio_transceiver.channels)):
coreaux_name = "drtioaux" + str(i)
memory_name = "drtioaux" + str(i) + "_mem"
drtioaux_csr_group.append(coreaux_name)
drtioaux_memory_group.append(memory_name)
cdr = ClockDomainsRenamer({"rtio_rx": "rtio_rx" + str(i)})
# Satellite
if i == 0:
self.submodules.rx_synchronizer = cdr(XilinxRXSynchronizer())
core = cdr(DRTIOSatellite(
self.rtio_tsc, self.drtio_transceiver.channels[0], self.rx_synchronizer))
self.submodules.drtiosat = core
self.csr_devices.append("drtiosat")
# Repeaters
else:
corerep_name = "drtiorep" + str(i-1)
drtiorep_csr_group.append(corerep_name)
core = cdr(DRTIORepeater(
self.rtio_tsc, self.drtio_transceiver.channels[i]))
setattr(self.submodules, corerep_name, core)
self.drtio_cri.append(core.cri)
self.csr_devices.append(corerep_name)
coreaux = cdr(drtio_aux_controller.DRTIOAuxControllerBare(core.link_layer))
setattr(self.submodules, coreaux_name, coreaux)
self.csr_devices.append(coreaux_name)
mem_size = coreaux.get_mem_size()
tx_port = coreaux.get_tx_port()
rx_port = coreaux.get_rx_port()
memory_address = self.axi2csr.register_port(tx_port, mem_size)
# rcv in upper half of the memory, thus added second
self.axi2csr.register_port(rx_port, mem_size)
# and registered in PS interface
# manually, because software refers to rx/tx by halves of entire memory block, not names
self.add_memory_region(memory_name, self.mem_map["csr"] + memory_address, mem_size * 2)
self.rustc_cfg["has_drtio"] = None
self.rustc_cfg["has_drtio_routing"] = None
self.add_csr_group("drtioaux", drtioaux_csr_group)
self.add_csr_group("drtiorep", drtiorep_csr_group)
self.add_memory_group("drtioaux_mem", drtioaux_memory_group)
self.rustc_cfg["rtio_frequency"] = str(self.drtio_transceiver.rtio_clk_freq/1e6)
# Si5324 Phaser
self.submodules.siphaser = SiPhaser7Series(
si5324_clkin=platform.request("si5324_clkin"),
rx_synchronizer=self.rx_synchronizer,
2021-11-29 12:48:45 +08:00
ultrascale=False,
rtio_clk_freq=self.drtio_transceiver.rtio_clk_freq)
platform.add_false_path_constraints(
self.ps7.cd_sys.clk, self.siphaser.mmcm_freerun_output)
self.csr_devices.append("siphaser")
self.submodules.si5324_rst_n = gpio.GPIOOut(platform.request("si5324_33").rst_n)
self.csr_devices.append("si5324_rst_n")
self.rustc_cfg["has_si5324"] = None
self.rustc_cfg["has_siphaser"] = None
rtio_clk_period = 1e9/self.drtio_transceiver.rtio_clk_freq
# Constrain TX & RX timing for the first transceiver channel
# (First channel acts as master for phase alignment for all channels' TX)
gtx0 = self.drtio_transceiver.gtxs[0]
platform.add_period_constraint(gtx0.txoutclk, rtio_clk_period)
platform.add_period_constraint(gtx0.rxoutclk, rtio_clk_period)
platform.add_false_path_constraints(
self.ps7.cd_sys.clk,
gtx0.txoutclk, gtx0.rxoutclk)
# Constrain RX timing for the each transceiver channel
# (Each channel performs single-lane phase alignment for RX)
for gtx in self.drtio_transceiver.gtxs[1:]:
platform.add_period_constraint(gtx.rxoutclk, rtio_clk_period)
platform.add_false_path_constraints(
self.ps7.cd_sys.clk, gtx.rxoutclk)
self.submodules.rtio_crg = RTIOClockMultiplier(self.sys_clk_freq)
self.csr_devices.append("rtio_crg")
fix_serdes_timing_path(self.platform)
def add_rtio(self, rtio_channels):
self.submodules.rtio_moninj = rtio.MonInj(rtio_channels)
self.csr_devices.append("rtio_moninj")
if self.acpki:
self.rustc_cfg["ki_impl"] = "acp"
self.submodules.rtio = acpki.KernelInitiator(self.rtio_tsc,
bus=self.ps7.s_axi_acp,
user=self.ps7.s_axi_acp_user,
evento=self.ps7.event.o)
self.csr_devices.append("rtio")
else:
self.rustc_cfg["ki_impl"] = "csr"
self.submodules.rtio = rtio.KernelInitiator(self.rtio_tsc, now64=True)
self.csr_devices.append("rtio")
self.submodules.local_io = SyncRTIO(self.rtio_tsc, rtio_channels)
self.submodules.cri_con = rtio.CRIInterconnectShared(
[self.drtiosat.cri],
[self.local_io.cri] + self.drtio_cri,
mode="sync", enable_routing=True)
self.csr_devices.append("cri_con")
self.submodules.routing_table = rtio.RoutingTableAccess(self.cri_con)
self.csr_devices.append("routing_table")
2020-05-07 17:05:00 +08:00
class _NIST_CLOCK_RTIO:
2020-05-07 17:05:00 +08:00
"""
NIST clock hardware, with old backplane and 11 DDS channels
"""
def __init__(self):
2020-05-07 17:05:00 +08:00
platform = self.platform
platform.add_extension(nist_clock.fmc_adapter_io)
platform.add_extension(leds_fmc33)
platform.add_extension(pmod1_33)
platform.add_extension(_ams101_dac)
2021-10-14 16:37:13 +08:00
platform.add_extension(_pmod_spi)
2020-05-07 17:05:00 +08:00
rtio_channels = []
2020-05-07 17:05:00 +08:00
for i in range(16):
if i % 4 == 3:
2020-07-08 20:02:46 +08:00
phy = ttl_serdes_7series.InOut_8X(platform.request("ttl", i))
2020-05-07 17:05:00 +08:00
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=512))
else:
2020-07-08 20:02:46 +08:00
phy = ttl_serdes_7series.Output_8X(platform.request("ttl", i))
2020-05-07 17:05:00 +08:00
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy))
for i in range(2):
2020-07-08 20:02:46 +08:00
phy = ttl_serdes_7series.InOut_8X(platform.request("pmt", i))
2020-05-07 17:05:00 +08:00
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=512))
# no SMA GPIO, replaced with PMOD1_0
phy = ttl_serdes_7series.InOut_8X(platform.request("pmod1_33", 0))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=512))
phy = ttl_simple.Output(platform.request("user_led_33", 0))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy))
ams101_dac = self.platform.request("ams101_dac", 0)
phy = ttl_simple.Output(ams101_dac.ldac)
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy))
2020-05-07 17:05:00 +08:00
phy = ttl_simple.ClockGen(platform.request("la32_p"))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy))
phy = spi2.SPIMaster(ams101_dac)
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(
phy, ififo_depth=4))
2020-05-07 17:05:00 +08:00
for i in range(3):
phy = spi2.SPIMaster(self.platform.request("spi", i))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(
phy, ififo_depth=128))
# no SDIO on PL side, dummy SPI placeholder instead
2021-10-14 16:37:13 +08:00
phy = spi2.SPIMaster(platform.request("pmod_spi"))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=4))
2020-05-07 17:05:00 +08:00
phy = dds.AD9914(platform.request("dds"), 11, onehot=True)
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=4))
2020-07-19 14:05:35 +08:00
self.config["RTIO_LOG_CHANNEL"] = len(rtio_channels)
rtio_channels.append(rtio.LogChannel())
2020-05-07 17:05:00 +08:00
self.add_rtio(rtio_channels)
class _NIST_QC2_RTIO:
2020-05-07 17:05:00 +08:00
"""
NIST QC2 hardware, as used in Quantum I and Quantum II, with new backplane
and 24 DDS channels. Two backplanes are used.
"""
def __init__(self):
2020-05-07 17:05:00 +08:00
platform = self.platform
platform.add_extension(nist_qc2.fmc_adapter_io)
platform.add_extension(leds_fmc33)
platform.add_extension(_ams101_dac)
platform.add_extension(pmod1_33)
2020-05-07 17:05:00 +08:00
rtio_channels = []
2020-05-07 17:05:00 +08:00
# All TTL channels are In+Out capable
for i in range(40):
2020-07-08 20:02:46 +08:00
phy = ttl_serdes_7series.InOut_8X(platform.request("ttl", i))
2020-05-07 17:05:00 +08:00
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=512))
# no SMA GPIO, replaced with PMOD1_0
phy = ttl_serdes_7series.InOut_8X(platform.request("pmod1_33", 0))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=512))
phy = ttl_simple.Output(platform.request("user_led_33", 0))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy))
ams101_dac = self.platform.request("ams101_dac", 0)
phy = ttl_simple.Output(ams101_dac.ldac)
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy))
2020-05-07 17:05:00 +08:00
# CLK0, CLK1 are for clock generators, on backplane SMP connectors
for i in range(2):
phy = ttl_simple.ClockGen(
platform.request("clkout", i))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy))
phy = spi2.SPIMaster(ams101_dac)
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(
phy, ififo_depth=4))
2020-05-07 17:05:00 +08:00
for i in range(4):
phy = spi2.SPIMaster(self.platform.request("spi", i))
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(
phy, ififo_depth=128))
for backplane_offset in range(2):
phy = dds.AD9914(
platform.request("dds", backplane_offset), 12, onehot=True)
self.submodules += phy
rtio_channels.append(rtio.Channel.from_phy(phy, ififo_depth=4))
2020-07-19 14:05:35 +08:00
self.config["RTIO_LOG_CHANNEL"] = len(rtio_channels)
rtio_channels.append(rtio.LogChannel())
2020-05-07 17:05:00 +08:00
self.add_rtio(rtio_channels)
class NIST_CLOCK(ZC706, _NIST_CLOCK_RTIO):
def __init__(self, acpki):
ZC706.__init__(self, acpki)
_NIST_CLOCK_RTIO.__init__(self)
class NIST_CLOCK_Master(_MasterBase, _NIST_CLOCK_RTIO):
def __init__(self, acpki):
_MasterBase.__init__(self, acpki)
_NIST_CLOCK_RTIO.__init__(self)
class NIST_CLOCK_Satellite(_SatelliteBase, _NIST_CLOCK_RTIO):
def __init__(self, acpki):
_SatelliteBase.__init__(self, acpki)
_NIST_CLOCK_RTIO.__init__(self)
class NIST_QC2(ZC706, _NIST_QC2_RTIO):
def __init__(self, acpki):
ZC706.__init__(self, acpki)
_NIST_QC2_RTIO.__init__(self)
class NIST_QC2_Master(_MasterBase, _NIST_QC2_RTIO):
def __init__(self, acpki):
_MasterBase.__init__(self, acpki)
_NIST_QC2_RTIO.__init__(self)
class NIST_QC2_Satellite(_SatelliteBase, _NIST_QC2_RTIO):
def __init__(self, acpki):
_SatelliteBase.__init__(self, acpki)
_NIST_QC2_RTIO.__init__(self)
2021-10-08 17:07:12 +08:00
VARIANTS = {cls.__name__.lower(): cls for cls in [NIST_CLOCK, NIST_CLOCK_Master, NIST_CLOCK_Satellite,
NIST_QC2, NIST_QC2_Master, NIST_QC2_Satellite]}
2020-05-07 17:05:00 +08:00
2020-04-11 17:39:16 +08:00
def write_csr_file(soc, filename):
with open(filename, "w") as f:
f.write(cpu_interface.get_csr_rust(
soc.get_csr_regions(), soc.get_csr_groups(), soc.get_constants()))
def write_mem_file(soc, filename):
with open(filename, "w") as f:
f.write(cpu_interface.get_mem_rust(
soc.get_memory_regions(), soc.get_memory_groups(), None))
2020-04-11 17:39:16 +08:00
def write_rustc_cfg_file(soc, filename):
with open(filename, "w") as f:
for k, v in sorted(soc.rustc_cfg.items(), key=itemgetter(0)):
if v is None:
f.write("{}\n".format(k))
else:
f.write("{}=\"{}\"\n".format(k, v))
2020-04-11 17:39:16 +08:00
def main():
parser = argparse.ArgumentParser(
description="ARTIQ port to the ZC706 Zynq development kit")
parser.add_argument("-r", default=None,
help="build Rust interface into the specified file")
parser.add_argument("-m", default=None,
help="build Rust memory interface into the specified file")
parser.add_argument("-c", default=None,
help="build Rust compiler configuration into the specified file")
2020-05-07 13:52:40 +08:00
parser.add_argument("-g", default=None,
help="build gateware into the specified directory")
2021-10-08 17:07:12 +08:00
parser.add_argument("-V", "--variant", default="nist_clock",
2020-05-07 17:05:00 +08:00
help="variant: "
2021-10-08 17:07:12 +08:00
"[acpki_]nist_clock/nist_qc2[_master/_satellite] "
2020-05-07 17:05:00 +08:00
"(default: %(default)s)")
2020-04-11 17:39:16 +08:00
args = parser.parse_args()
variant = args.variant.lower()
acpki = variant.startswith("acpki_")
if acpki:
variant = variant[6:]
2020-05-07 17:05:00 +08:00
try:
cls = VARIANTS[variant]
2020-05-07 17:05:00 +08:00
except KeyError:
raise SystemExit("Invalid variant (-V/--variant)")
soc = cls(acpki=acpki)
2020-04-11 17:39:16 +08:00
soc.finalize()
if args.r is not None:
write_csr_file(soc, args.r)
if args.m is not None:
write_mem_file(soc, args.m)
if args.c is not None:
write_rustc_cfg_file(soc, args.c)
if args.g is not None:
soc.build(build_dir=args.g)
2020-04-11 17:39:16 +08:00
if __name__ == "__main__":