forked from M-Labs/artiq
shuttler: fix calibration channel target
This commit is contained in:
parent
eb08c55abe
commit
55150ebdbb
|
@ -224,8 +224,7 @@ class ADC:
|
|||
volts[ch].set_waveform(
|
||||
shuttler_volt_to_mu(samples[i]), 0, 0, 0)
|
||||
trigger.trigger(1 << ch)
|
||||
delay(1*us)
|
||||
measurements[i] = self.read_ch(ch ^ 1)
|
||||
measurements[i] = self.read_ch(ch)
|
||||
|
||||
# Find the average output slope
|
||||
print(measurements)
|
||||
|
|
Loading…