7210: fix specs

Replaced plot with the one produced by a faster scope (20 GSa/s).
master
occheung 2022-07-25 16:25:26 +08:00
parent 5d8dc38db7
commit a14aa89a76
2 changed files with 0 additions and 7 deletions

View File

@ -281,8 +281,6 @@ The output is connected to an oscilloscope with 50\textOmega~termination.
Clock output
& & 0.8 & & V\textsubscript{p-p} & \multirow{3}{*}{50\textOmega~load, 100 MHz} \\
& & 5 & & dBm & \\
\cline{0-4}
Rise time (-200mV to 200mV) & & 415 & & ps & \\
\thickhline
\end{tabularx}
\end{threeparttable}
@ -294,11 +292,6 @@ The output is connected to an oscilloscope with 50\textOmega~termination.
\caption{Waveform of Clocker at 100 MHz}
\end{figure}
\begin{figure}[H]
\centering
\includegraphics[width=5in]{clocker_rise_time.png}
\caption{Rising Edge of Clocker at 100 MHz}
\end{figure}
\newpage
\section{Selecting Clock Source}