parent
439edc4302
commit
6b24b54f60
@ -19,6 +19,7 @@
|
||||
\usepackage{tikz}
|
||||
\usepackage{pgfplots}
|
||||
\usepackage{circuitikz}
|
||||
\usepackage{pifont}
|
||||
\usetikzlibrary{calc}
|
||||
\usetikzlibrary{fit,backgrounds}
|
||||
|
||||
@ -395,6 +396,32 @@ All specifications are in $0\degree C \leq T_A \leq 70\degree C$ unless otherwis
|
||||
|
||||
\newpage
|
||||
|
||||
\section{Configuring IO Direction \& Termination}
|
||||
The termination and IO direction can be configured by switches.
|
||||
The per-channel termination and per-bank IO direction switches are found at the middle-left and middle-right of both cards respectively.
|
||||
|
||||
Termination switches selects the termination of each channel, between high impedence (OFF) and 50\textOmega~(ON).
|
||||
|
||||
IO direction switches partly decides the IO direction of each bank.
|
||||
\begin{itemize}
|
||||
\itemsep0em
|
||||
\item Closed switch (ON) \\
|
||||
Fix the corresponding bank to output. The direction cannot be changed by I\textsuperscript{2}C.
|
||||
\item Opened switch (OFF) \\
|
||||
Leave the direction configurable by I\textsuperscript{2}C.
|
||||
\end{itemize}
|
||||
|
||||
\begin{figure}[hbt!]
|
||||
\centering
|
||||
\subfloat[\centering BNC-TTL]{{
|
||||
\includegraphics[height=1.5in]{bnc_ttl_switches.jpg}
|
||||
}}%
|
||||
\subfloat[\centering SMA-TTL]{{
|
||||
\includegraphics[height=1.5in]{sma_ttl_switches.jpg}
|
||||
}}%
|
||||
\caption{Position of switches}%
|
||||
\end{figure}
|
||||
|
||||
\section{Example ARTIQ code}
|
||||
The sections below demonstrate simple usage scenarios of the 2118 BNC-TTL/2128 SMA-TTL card with the ARTIQ control system.
|
||||
They do not exhaustively demonstrate all the features of the ARTIQ system.
|
||||
@ -414,6 +441,8 @@ def run(self):
|
||||
delay(500*ms)
|
||||
\end{minted}
|
||||
|
||||
\newpage
|
||||
|
||||
\subsection{Morse code}
|
||||
This example demonstrates some basic algorithmic features of the ARTIQ-Python language.
|
||||
\begin{minted}{python}
|
||||
@ -437,8 +466,6 @@ def run(self):
|
||||
delay(700*ms)
|
||||
\end{minted}
|
||||
|
||||
\newpage
|
||||
|
||||
\subsection{Counting rising edges in a 1ms window}
|
||||
The channel should be configured as input in both the gateware and hardware.
|
||||
|
||||
@ -462,6 +489,8 @@ def run(self):
|
||||
print(counts)
|
||||
\end{minted}
|
||||
|
||||
\newpage
|
||||
|
||||
\subsection{Responding to an external trigger}
|
||||
One channel needs to be configured as input, and the other as output.
|
||||
|
||||
|
22
2238.tex
22
2238.tex
@ -524,6 +524,28 @@ All specifications are in the recommended operating temperature range unless oth
|
||||
\end{threeparttable}
|
||||
\end{table}
|
||||
|
||||
\section{Configuring IO Direction \& Termination}
|
||||
The termination and IO direction can be configured by switches.
|
||||
The per-channel termination and per-bank IO direction switches are found at the top and middle of the card respectively.
|
||||
\begin{multicols}{2}
|
||||
Termination switches selects the termination of each channel, between high impedence (OFF) and 50\textOmega~(ON).
|
||||
|
||||
IO direction switches partly decides the IO direction of each bank.
|
||||
\begin{itemize}
|
||||
\itemsep0em
|
||||
\item Closed switch (ON) \\
|
||||
Fix the corresponding bank to output. The direction cannot be changed by I\textsuperscript{2}C.
|
||||
\item Opened switch (OFF) \\
|
||||
Leave the direction configurable by I\textsuperscript{2}C.
|
||||
\end{itemize}
|
||||
\columnbreak
|
||||
\begin{center}
|
||||
\centering
|
||||
\includegraphics[height=1.8in]{mcx_ttl_switches.jpg}
|
||||
\captionof{figure}{Position of switches}
|
||||
\end{center}
|
||||
\end{multicols}
|
||||
|
||||
\newpage
|
||||
\section{Example ARTIQ code}
|
||||
The sections below demonstrate simple usage scenarios of the 2245 LVDS-TTL card with the ARTIQ control system.
|
||||
|
27
2245.tex
27
2245.tex
@ -443,6 +443,27 @@ All typical values of AC specifications are at $T_A = 25\degree C$, $V_{ID} = 30
|
||||
\end{threeparttable}
|
||||
\end{table}
|
||||
|
||||
\section{Configuring IO Direction \& Termination}
|
||||
The IO direction can be configured by switches, which are found at the top of the card.
|
||||
\begin{multicols}{2}
|
||||
IO direction switches partly decides the IO direction of each bank.
|
||||
\begin{itemize}
|
||||
\itemsep0em
|
||||
\item Closed switch (ON) \\
|
||||
Fix the corresponding channel to output. The direction cannot be changed by I\textsuperscript{2}C.
|
||||
\item Opened switch (OFF) \\
|
||||
Leave the direction configurable by I\textsuperscript{2}C.
|
||||
\end{itemize}
|
||||
\columnbreak
|
||||
\begin{center}
|
||||
\centering
|
||||
\includegraphics[height=1.5in]{lvds_ttl_switches.jpg}
|
||||
\captionof{figure}{Position of switches}
|
||||
\end{center}
|
||||
\end{multicols}
|
||||
|
||||
\newpage
|
||||
|
||||
\section{Example ARTIQ code}
|
||||
The sections below demonstrate simple usage scenarios of the 2245 LVDS-TTL card with the ARTIQ control system.
|
||||
They do not exhaustively demonstrate all the features of the ARTIQ system.
|
||||
@ -462,8 +483,6 @@ def run(self):
|
||||
delay(500*ms)
|
||||
\end{minted}
|
||||
|
||||
\newpage
|
||||
|
||||
\subsection{Morse code}
|
||||
This example demonstrates some basic algorithmic features of the ARTIQ-Python language.
|
||||
\begin{minted}{python}
|
||||
@ -487,6 +506,8 @@ def run(self):
|
||||
delay(700*ms)
|
||||
\end{minted}
|
||||
|
||||
\newpage
|
||||
|
||||
\subsection{Counting rising edges in a 1ms window}
|
||||
The channel should be configured as input in both the gateware and hardware.
|
||||
|
||||
@ -510,8 +531,6 @@ def run(self):
|
||||
print(counts)
|
||||
\end{minted}
|
||||
|
||||
\newpage
|
||||
|
||||
\subsection{Responding to an external trigger}
|
||||
One channel needs to be configured as input, and the other as output.
|
||||
|
||||
|
BIN
bnc_ttl_switches.jpg
Normal file
BIN
bnc_ttl_switches.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 262 KiB |
BIN
lvds_ttl_switches.jpg
Normal file
BIN
lvds_ttl_switches.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 318 KiB |
BIN
mcx_ttl_switches.jpg
Normal file
BIN
mcx_ttl_switches.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 192 KiB |
BIN
sma_ttl_switches.jpg
Normal file
BIN
sma_ttl_switches.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 120 KiB |
Loading…
Reference in New Issue