@ -92,18 +92,28 @@ Setup
|
||||
If the board was running stock ARTIQ before, the settings will be kept.
|
||||
* A 2 GHz of roughly 10 dBm (0.2 to 3.4 V peak-to-peak into 50 Ohm) must be connected to the AD9154-FMC-EBZ J1.
|
||||
The external RTIO clock, DAC deviceclock, FPGA deviceclock, and SYSREF are derived from this signal.
|
||||
* An example device database, several status and test scripts are provided in ``artiq/examples/phaser/``. ::
|
||||
|
||||
cd artiq/examples/phaser
|
||||
|
||||
* Edit ``device_db.pyon`` to match the hostname or IP address of the core device.
|
||||
* The ``startup_clock`` needs to be set to internal (``i``) for bootstrapping the clock distribution tree.
|
||||
* Compile and flash the startup kernel in ``artiq/examples/phaser/startup_kernel.py``.
|
||||
* Erase any possible idle kernels.
|
||||
* Use ``ping`` and ``flterm`` to verify that the core device starts up and boots correctly.
|
||||
|
||||
Usage
|
||||
-----
|
||||
|
||||
* An example device database, several status and test scripts are provided in ``artiq/examples/phaser/``.
|
||||
* After each boot, run the ``dac_setup.py`` experiment to establish the JESD204B links (``artiq_run repository/dac_setup.py``).
|
||||
* Run ``artiq_run repository/ad9154_test_status.py`` to retrieve and print several status registers from the AD9154 DAC.
|
||||
* Run ``artiq_run repository/ad9154_test_prbs.py`` to test the JESD204B PHY layer for bit errors. Reboot the core device afterwards.
|
||||
* Run ``artiq_run repository/ad9154_test_stpl.py`` to executes a JESD204B short transport layer test.
|
||||
* Run ``artiq_run repository/sawg.py`` for an example that sets up amplitudes, frequencies, and phases on all four DDS channels.
|
||||
* Run ``artiq_run repository/demo.py`` for an example that exercises several different use cases of synchronized phase, amplitude, and frequency updates.
|
||||
for an example that exercises several different use cases of synchronized phase, amplitude, and frequency updates.
|
||||
* Implement your own experiments using the SAWG channels.
|
||||
* Verify clock stability between the 2 GHz reference clock and the DAC outputs.
|
||||
* Verify phase alignment between the DAC channels.
|
||||
* Changes to the AD9154 configuration can also be performed at runtime in experiments.
|
||||
See the example ``dac_setup.py``.
|
||||
This can e.g. be used to enable and evaluate mix mode without having to change any other code (bitstream/bios/runtime/startup_kernel).
|
||||
|