@ -133,6 +133,8 @@ The :meth:`artiq.coredevice.ttl.TTLInOut.count` method of an input channel can l
|
|||
The :meth:`artiq.coredevice.ttl.TTLInOut.gate_rising` method leaves the timeline cursor at the closure time of the gate and ``count()`` must necessarily wait until the gate closing event has actually been executed which is sometime with ``rtio_counter > now``.
|
||||
In these situations where ``count()`` leads to a synchronization of timeline cursor and wall clock, a ``delay()`` is necessary to reestablish positive slack so that output events can be placed.
|
||||
|
||||
Similar situations arise with methods such as :meth:`artiq.coredevice.ttl.TTLInOut.sample_get` and :meth:`artiq.coredevice.ttl.TTLInOut.watch_done`.
|
||||
|
||||
.. wavedrom::
|
||||
{
|
||||
signal: [
|
||||
|
@ -151,10 +153,10 @@ In these situations where ``count()`` leads to a synchronization of timeline cur
|
|||
Overflow exceptions
|
||||
-------------------
|
||||
|
||||
The RTIO input channels buffer input events received while an input gate is open.
|
||||
The events are kept in a FIFO until the CPU reads them out via ``count()`` (or :meth:`artiq.coredevice.ttl.TTLInOut.timestamp_mu`).
|
||||
The RTIO input channels buffer input events received while an input gate is open, or at certain points in time when using the sampling API (:meth:`artiq.coredevice.ttl.TTLInOut.sample_input`).
|
||||
The events are kept in a FIFO until the CPU reads them out via e.g. :meth:`artiq.coredevice.ttl.TTLInOut.count`, :meth:`artiq.coredevice.ttl.TTLInOut.timestamp_mu` or :meth:`artiq.coredevice.ttl.TTLInOut.sample_get`.
|
||||
If the FIFO is full and another event is coming in, this causes an overflow condition.
|
||||
The condition is converted into an :class:`artiq.coredevice.exceptions.RTIOOverflow` exception that is raised on a subsequent invocation of one of the readout methods (``count()`` or ``timestamp_mu()``).
|
||||