forked from M-Labs/artiq
1
0
Fork 0

grabber: Add optional timeout for getting grabber data

Signed-off-by: Charles Baynham <c.baynham@imperial.ac.uk>
This commit is contained in:
Charles Baynham 2024-01-25 13:54:25 +00:00 committed by Sébastien Bourdeauducq
parent 4c142ec3f1
commit 20d7604f87
2 changed files with 21 additions and 5 deletions

View File

@ -46,6 +46,7 @@ Highlights:
* MSYS2 packaging for Windows, which replaces Conda. Conda packages are still available to
support legacy installations, but may be removed in a future release.
* Experiments can now be submitted with revisions set to a branch / tag name instead of only git hashes.
* Grabber image input now has an optional timeout
Breaking changes:

View File

@ -2,7 +2,7 @@ from numpy import int32, int64
from artiq.language.core import *
from artiq.language.types import *
from artiq.coredevice.rtio import rtio_output, rtio_input_data
from artiq.coredevice.rtio import rtio_output, rtio_input_timestamped_data
class OutOfSyncException(Exception):
@ -11,6 +11,11 @@ class OutOfSyncException(Exception):
pass
class GrabberTimeoutException(Exception):
"""Raised when a timeout occurs while attempting to read Grabber RTIO input events."""
pass
class Grabber:
"""Driver for the Grabber camera interface."""
kernel_invariants = {"core", "channel_base", "sentinel"}
@ -82,10 +87,10 @@ class Grabber:
self.gate_roi(0)
@kernel
def input_mu(self, data):
def input_mu(self, data, timeout_mu=-1):
"""
Retrieves the accumulated values for one frame from the ROI engines.
Blocks until values are available.
Blocks until values are available or timeout is reached.
The input list must be a list of integers of the same length as there
are enabled ROI engines. This method replaces the elements of the
@ -95,15 +100,25 @@ class Grabber:
If the number of elements in the list does not match the number of
ROI engines that produced output, an exception will be raised during
this call or the next.
If the timeout is reached before data is available, a RuntimeError is
raised.
:param timeout_mu: Timestamp at which a timeout will occur. Set to -1
(default) to disable timeout.
"""
channel = self.channel_base + 1
sentinel = rtio_input_data(channel)
timestamp, sentinel = rtio_input_timestamped_data(timeout_mu, channel)
if timestamp == -1:
raise GrabberTimeoutException("Timeout before Grabber frame available")
if sentinel != self.sentinel:
raise OutOfSyncException
for i in range(len(data)):
roi_output = rtio_input_data(channel)
timestamp, roi_output = rtio_input_timestamped_data(timeout_mu, channel)
if roi_output == self.sentinel:
raise OutOfSyncException
if timestamp == -1:
raise GrabberTimeoutException("Timeout retrieving ROIs")
data[i] = roi_output