Merge branch 'subprocess-termination'
* subprocess-termination: test_ctlmgr: fix Client: add note about timeout sideeffects hardware_testbench: full shutdown sequence for controllers worker: flake8 style cleanup ctlmgr: fix import pc_rpc.Client: support socket timeouts subprocesses: unify termination logic
This commit is contained in:
commit
055573a4af
@ -3,6 +3,7 @@ import logging
|
||||
import subprocess
|
||||
import shlex
|
||||
import socket
|
||||
import os
|
||||
|
||||
from artiq.protocols.sync_struct import Subscriber
|
||||
from artiq.protocols.pc_rpc import AsyncioClient
|
||||
@ -106,30 +107,40 @@ class Controller:
|
||||
await self._terminate()
|
||||
|
||||
async def _terminate(self):
|
||||
logger.info("Terminating controller %s", self.name)
|
||||
if self.process is not None and self.process.returncode is None:
|
||||
if self.process is None or self.process.returncode is not None:
|
||||
logger.info("Controller %s already terminated", self.name)
|
||||
return
|
||||
logger.debug("Terminating controller %s", self.name)
|
||||
try:
|
||||
await asyncio.wait_for(self.call("terminate"), self.term_timeout)
|
||||
await asyncio.wait_for(self.process.wait(), self.term_timeout)
|
||||
logger.info("Controller %s terminated", self.name)
|
||||
return
|
||||
except:
|
||||
logger.warning("Controller %s did not exit on request, "
|
||||
"ending the process", self.name)
|
||||
if os.name != "nt":
|
||||
try:
|
||||
await asyncio.wait_for(self.call("terminate"),
|
||||
self.term_timeout)
|
||||
except:
|
||||
logger.warning("Controller %s did not respond to terminate "
|
||||
"command, killing", self.name)
|
||||
try:
|
||||
self.process.kill()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
self.process.terminate()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
try:
|
||||
await asyncio.wait_for(self.process.wait(),
|
||||
self.term_timeout)
|
||||
except:
|
||||
logger.warning("Controller %s failed to exit, killing",
|
||||
self.name)
|
||||
try:
|
||||
self.process.kill()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
await self.process.wait()
|
||||
logger.debug("Controller %s terminated", self.name)
|
||||
await asyncio.wait_for(self.process.wait(), self.term_timeout)
|
||||
logger.info("Controller process %s terminated", self.name)
|
||||
return
|
||||
except asyncio.TimeoutError:
|
||||
logger.warning("Controller process %s did not terminate, "
|
||||
"killing", self.name)
|
||||
try:
|
||||
self.process.kill()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
try:
|
||||
await asyncio.wait_for(self.process.wait(), self.term_timeout)
|
||||
logger.info("Controller process %s killed", self.name)
|
||||
return
|
||||
except asyncio.TimeoutError:
|
||||
logger.warning("Controller process %s failed to die", self.name)
|
||||
|
||||
|
||||
def get_ip_addresses(host):
|
||||
|
@ -5,7 +5,6 @@ import logging
|
||||
import subprocess
|
||||
import traceback
|
||||
import time
|
||||
from functools import partial
|
||||
|
||||
from artiq.protocols import pipe_ipc, pyon
|
||||
from artiq.protocols.logging import LogParser
|
||||
@ -115,30 +114,38 @@ class Worker:
|
||||
" (RID %s)", self.ipc.process.returncode,
|
||||
self.rid)
|
||||
return
|
||||
obj = {"action": "terminate"}
|
||||
try:
|
||||
await self._send(obj, cancellable=False)
|
||||
await self._send({"action": "terminate"}, cancellable=False)
|
||||
await asyncio.wait_for(self.ipc.process.wait(), term_timeout)
|
||||
logger.debug("worker exited on request (RID %s)", self.rid)
|
||||
return
|
||||
except:
|
||||
logger.debug("failed to send terminate command to worker"
|
||||
" (RID %s), killing", self.rid, exc_info=True)
|
||||
logger.debug("worker failed to exit on request"
|
||||
" (RID %s), ending the process", self.rid,
|
||||
exc_info=True)
|
||||
if os.name != "nt":
|
||||
try:
|
||||
self.ipc.process.kill()
|
||||
self.ipc.process.terminate()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
await self.ipc.process.wait()
|
||||
return
|
||||
try:
|
||||
await asyncio.wait_for(self.ipc.process.wait(),
|
||||
term_timeout)
|
||||
logger.debug("worker terminated (RID %s)", self.rid)
|
||||
return
|
||||
except asyncio.TimeoutError:
|
||||
logger.warning(
|
||||
"worker did not terminate (RID %s), killing", self.rid)
|
||||
try:
|
||||
self.ipc.process.kill()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
try:
|
||||
await asyncio.wait_for(self.ipc.process.wait(), term_timeout)
|
||||
logger.debug("worker killed (RID %s)", self.rid)
|
||||
return
|
||||
except asyncio.TimeoutError:
|
||||
logger.debug("worker did not exit by itself (RID %s), killing",
|
||||
self.rid)
|
||||
try:
|
||||
self.ipc.process.kill()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
await self.ipc.process.wait()
|
||||
else:
|
||||
logger.debug("worker exited by itself (RID %s)", self.rid)
|
||||
logger.warning("worker refuses to die (RID %s)", self.rid)
|
||||
finally:
|
||||
self.io_lock.release()
|
||||
|
||||
@ -208,7 +215,8 @@ class Worker:
|
||||
reply = {"status": "ok", "data": data}
|
||||
except Exception as e:
|
||||
reply = {"status": "failed",
|
||||
"exception": traceback.format_exception_only(type(e), e)[0][:-1],
|
||||
"exception": traceback.format_exception_only(
|
||||
type(e), e)[0][:-1],
|
||||
"message": str(e),
|
||||
"traceback": traceback.format_tb(e.__traceback__)}
|
||||
await self.io_lock.acquire()
|
||||
@ -235,7 +243,8 @@ class Worker:
|
||||
del self.watchdogs[-1]
|
||||
return completed
|
||||
|
||||
async def build(self, rid, pipeline_name, wd, expid, priority, timeout=15.0):
|
||||
async def build(self, rid, pipeline_name, wd, expid, priority,
|
||||
timeout=15.0):
|
||||
self.rid = rid
|
||||
self.filename = os.path.basename(expid["file"])
|
||||
await self._create_process(expid["log_level"])
|
||||
@ -280,6 +289,7 @@ class Worker:
|
||||
|
||||
await self._create_process(logging.WARNING)
|
||||
r = dict()
|
||||
|
||||
def register(class_name, name, arginfo):
|
||||
r[class_name] = {"name": name, "arginfo": arginfo}
|
||||
self.register_experiment = register
|
||||
|
@ -57,8 +57,7 @@ def _validate_target_name(target_name, target_names):
|
||||
target_name = target_names[0]
|
||||
elif target_name not in target_names:
|
||||
raise IncompatibleServer(
|
||||
"valid target name(s): " +
|
||||
" ".join(sorted(target_names)))
|
||||
"valid target name(s): " + " ".join(sorted(target_names)))
|
||||
return target_name
|
||||
|
||||
|
||||
@ -92,9 +91,16 @@ class Client:
|
||||
Use ``None`` to skip selecting a target. The list of targets can then
|
||||
be retrieved using ``get_rpc_id`` and then one can be selected later
|
||||
using ``select_rpc_target``.
|
||||
:param timeout: Socket operation timeout. Use ``None`` for blocking
|
||||
(default), ``0`` for non-blocking, and a finite value to raise
|
||||
``socket.timeout`` if an operation does not complete within the
|
||||
given time. See also ``socket.create_connection()`` and
|
||||
``socket.settimeout()`` in the Python standard library. A timeout
|
||||
in the middle of a RPC can break subsequent RPCs (from the same
|
||||
client).
|
||||
"""
|
||||
def __init__(self, host, port, target_name=AutoTarget):
|
||||
self.__socket = socket.create_connection((host, port))
|
||||
def __init__(self, host, port, target_name=AutoTarget, timeout=None):
|
||||
self.__socket = socket.create_connection((host, port), timeout)
|
||||
|
||||
try:
|
||||
self.__socket.sendall(_init_string)
|
||||
@ -485,7 +491,8 @@ class Server(_AsyncioServer):
|
||||
obj = {"status": "ok", "ret": doc}
|
||||
elif obj["action"] == "call":
|
||||
logger.debug("calling %s", _PrettyPrintCall(obj))
|
||||
if self.builtin_terminate and obj["name"] == "terminate":
|
||||
if (self.builtin_terminate and obj["name"] ==
|
||||
"terminate"):
|
||||
self._terminate_request.set()
|
||||
obj = {"status": "ok", "ret": None}
|
||||
else:
|
||||
|
@ -8,11 +8,13 @@ import logging
|
||||
import subprocess
|
||||
import shlex
|
||||
import time
|
||||
import socket
|
||||
|
||||
from artiq.master.databases import DeviceDB, DatasetDB
|
||||
from artiq.master.worker_db import DeviceManager, DatasetManager
|
||||
from artiq.coredevice.core import CompileError
|
||||
from artiq.frontend.artiq_run import DummyScheduler
|
||||
from artiq.protocols.pc_rpc import AutoTarget, Client
|
||||
|
||||
|
||||
artiq_root = os.getenv("ARTIQ_ROOT")
|
||||
@ -27,13 +29,13 @@ class ControllerCase(unittest.TestCase):
|
||||
self.controllers = {}
|
||||
|
||||
def tearDown(self):
|
||||
for name in self.controllers:
|
||||
self.device_mgr.get(name).terminate()
|
||||
self.device_mgr.close_devices()
|
||||
for name in list(self.controllers):
|
||||
self.stop_controller(name)
|
||||
|
||||
def start_controller(self, name, sleep=1):
|
||||
if name in self.controllers:
|
||||
raise ValueError("controller `{}` already started".format(name))
|
||||
try:
|
||||
entry = self.device_db.get(name)
|
||||
except KeyError:
|
||||
@ -46,15 +48,43 @@ class ControllerCase(unittest.TestCase):
|
||||
time.sleep(sleep)
|
||||
|
||||
def stop_controller(self, name, default_timeout=1):
|
||||
entry, proc = self.controllers[name]
|
||||
t = entry.get("term_timeout", default_timeout)
|
||||
proc.terminate()
|
||||
desc, proc = self.controllers[name]
|
||||
t = desc.get("term_timeout", default_timeout)
|
||||
target_name = desc.get("target_name", None)
|
||||
if target_name is None:
|
||||
target_name = AutoTarget
|
||||
try:
|
||||
proc.wait(t)
|
||||
except subprocess.TimeoutExpired:
|
||||
proc.kill()
|
||||
proc.wait(t)
|
||||
del self.controllers[name]
|
||||
try:
|
||||
client = Client(desc["host"], desc["port"], target_name, t)
|
||||
try:
|
||||
client.terminate()
|
||||
finally:
|
||||
client.close_rpc()
|
||||
proc.wait(t)
|
||||
return
|
||||
except (socket.timeout, subprocess.TimeoutExpired):
|
||||
logger.warning("Controller %s failed to exit on request", name)
|
||||
try:
|
||||
proc.terminate()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
try:
|
||||
proc.wait(t)
|
||||
return
|
||||
except subprocess.TimeoutExpired:
|
||||
logger.warning("Controller %s failed to exit on terminate",
|
||||
name)
|
||||
try:
|
||||
proc.kill()
|
||||
except ProcessLookupError:
|
||||
pass
|
||||
try:
|
||||
proc.wait(t)
|
||||
return
|
||||
except subprocess.TimeoutExpired:
|
||||
logger.warning("Controller %s failed to die on kill", name)
|
||||
finally:
|
||||
del self.controllers[name]
|
||||
|
||||
|
||||
@unittest.skipUnless(artiq_root, "no ARTIQ_ROOT")
|
||||
|
@ -56,7 +56,6 @@ class ControllerCase(unittest.TestCase):
|
||||
raise asyncio.TimeoutError
|
||||
|
||||
def test_start_ping_stop_controller(self):
|
||||
command = sys.executable + " -m "
|
||||
entry = {
|
||||
"type": "controller",
|
||||
"host": "::1",
|
||||
@ -67,5 +66,6 @@ class ControllerCase(unittest.TestCase):
|
||||
async def test():
|
||||
await self.start("lda_sim", entry)
|
||||
remote = await self.get_client(entry["host"], entry["port"])
|
||||
await remote.ping()
|
||||
|
||||
self.loop.run_until_complete(test())
|
||||
|