Utilities
=========
2016-01-19 12:41:42 +08:00
.. Sort these tool by some subjective combination of their
typical sequence and expected frequency of use.
2015-01-23 00:52:13 +08:00
Local running tool
------------------
.. argparse::
:ref: artiq.frontend.artiq_run.get_argparser
:prog: artiq_run
Static compiler
---------------
This tool compiles an experiment into a ELF file. It is primarily used to prepare binaries for the default experiment loaded in non-volatile storage of the core device.
Experiments compiled with this tool are not allowed to use RPCs, and their ``run`` entry point must be a kernel.
.. argparse::
:ref: artiq.frontend.artiq_compile.get_argparser
:prog: artiq_compile
2015-04-30 20:03:11 +08:00
Flash storage image generator
-----------------------------
This tool compiles key/value pairs into a binary image suitable for flashing into the flash storage space of the core device.
.. argparse::
:ref: artiq.frontend.artiq_mkfs.get_argparser
:prog: artiq_mkfs
2016-01-19 12:41:42 +08:00
Flashing/Loading tool
---------------------
.. argparse::
:ref: artiq.frontend.artiq_flash.get_argparser
:prog: artiq_flash
.. _core-device-management-tool:
Core device management tool
---------------------------
The artiq_coremgmt utility gives remote access to the core device logs, the :ref:`core-device-flash-storage`, and other management functions.
To use this tool, you need to specify a ``device_db.py`` device database file which contains a ``comm`` device (an example is provided in ``examples/master/device_db.py``). This tells the tool how to connect to the core device and with which parameters (e.g. IP address, TCP port). When not specified, the artiq_coremgmt utility will assume that there is a file named ``device_db.py`` in the current directory.
To read core device logs::
$ artiq_coremgmt log
2018-05-23 05:32:00 +08:00
To set core device log level and UART log level (possible levels are ``TRACE``, ``DEBUG``, ``INFO``, ``WARN`` and ``ERROR``)::
$ artiq_coremgmt log set_level LEVEL
$ artiq_coremgmt log set_uart_level LEVEL
2018-05-23 05:32:00 +08:00
Note that enabling the ``TRACE`` log level results in small core device slowdown, and printing large amounts of log messages to the UART results in significant core device slowdown.
To read the record whose key is ``mac``::
$ artiq_coremgmt config read mac
To write the value ``test_value`` in the key ``my_key``::
$ artiq_coremgmt config write -s my_key test_value
$ artiq_coremgmt config read my_key
b'test_value'
You can also write entire files in a record using the ``-f`` parameter. This is useful for instance to write the startup and idle kernels in the flash storage::
$ artiq_coremgmt config write -f idle_kernel idle.elf
$ artiq_coremgmt config read idle_kernel | head -c9
b'\x7fELF
You can write several records at once::
$ artiq_coremgmt config write -s key1 value1 -f key2 filename -s key3 value3
To remove the previously written key ``my_key``::
$ artiq_coremgmt config remove my_key
2015-06-18 23:07:03 +08:00
You can remove several keys at once::
$ artiq_coremgmt config remove key1 key2
To erase the entire flash storage area::
$ artiq_coremgmt config erase
You do not need to remove a record in order to change its value, just overwrite it::
$ artiq_coremgmt config write -s my_key some_value
$ artiq_coremgmt config write -s my_key some_other_value
$ artiq_coremgmt config read my_key
b'some_other_value'
.. argparse::
:ref: artiq.frontend.artiq_coremgmt.get_argparser
:prog: artiq_coremgmt
Core device logging controller
------------------------------
.. argparse::
:ref: artiq.frontend.aqctl_corelog.get_argparser
:prog: aqctl_corelog
2016-02-16 05:43:02 +08:00
.. _core-device-rtio-analyzer-tool:
Core device RTIO analyzer tool
------------------------------
:mod:`~artiq.frontend.artiq_coreanalyzer` is a tool to convert core device RTIO logs to VCD waveform files that are readable by third-party tools such as GtkWave. This tool extracts pre-recorded data from an ARTIQ core device buffer (or from a file with the ``-r`` option), and converts it to a standard VCD file format. See :ref:`rtio-analyzer-example` for an example, or :mod:`artiq.test.coredevice.test_analyzer` for a relevant unit test.
.. argparse::
:ref: artiq.frontend.artiq_coreanalyzer.get_argparser
:prog: artiq_coreanalyzer
2015-08-17 15:44:40 +08:00
.. _routing-table-tool:
DRTIO routing table manipulation tool
-------------------------------------
.. argparse::
:ref: artiq.frontend.artiq_route.get_argparser
:prog: artiq_route