4d8e16771e gui: Correct Pid Autotune output current limit 2024-10-29 12:59:15 +08:00
4d332328c0 gui: Limit min PD Mon Pwr y axis range to 0-100uW 2024-10-23 12:24:57 +08:00
edb8099a26 Add pglive patch for setting y-axis min range span 2024-10-23 12:24:57 +08:00
49dc8a9b96 gui: autotuner only set_i when relay state changes
- Previously, autotuner issues set_i cmd for each report obj received
- These change increase the maximum autotune-able PID update rate with GUI
2024-10-22 18:09:39 +08:00
a1b7538295 driver: Fix disconnection bug at high cmd rate
- Disconnection issue can be triggered by setting high polling rate
(500Hz) and then interactive with gui elements
2024-10-22 18:09:28 +08:00
8f5a294a53 gui: Fix graphs' refresh rate to be 10Hz
- Reduce unnecessary CPU usage
2024-10-22 10:57:55 +08:00
87b0e1bf67 gui: rm sIPrefix from PD Current readings 2024-10-21 11:15:15 +08:00
35f66c3516 gui: Change LD, Thermostat Status Display Method
- Use combinations of label and stylesheet border to create visual cue for status
2024-10-18 17:33:54 +08:00
dd7e1bbbdd gui: Adjust y_axis limit range of graphs 2024-10-18 17:33:09 +08:00
a3b38fc6b7 gui: Unify the param tree unit formatting style 2024-10-18 17:33:01 +08:00
388e6725ef thermostat: Clear alarm when settings are loaded 2024-10-17 17:36:17 +08:00
f4c761c5ca pid: Scale PID Parameters with Sampling Rate
- Breaking changes
2024-10-17 17:36:06 +08:00
e560d8f1eb thermostat, gui: Set max v range according to datasheet 2024-10-16 16:21:11 +08:00
0437c6e76e thermostat, gui: Relax the max settable TEC Current Limit
- Improper settings can cause PoE power failure and over heating
- See hardware repo Issue #51
2024-10-16 16:14:58 +08:00
bad21806f8 gui: Add new form for temp adc filter cfg and settable polling rate
List of Changes:
1. Get report via polling instead of active report mode
2. Allow user to set a custom report polling rate while settings polling rate is fixed to 10Hz
- it is necessary for pid autotune to function correctly
3. Add a form for configuring temperature adc filter
4. Use two different timer for polling report and settings to optimize performance

Known Issue:
1. CPU utilization increases with the report polling rate as for each report recv-ed, gui renders and plots one frame of the 4 graphs
2024-10-10 17:25:33 +08:00
cb2bc505c9 driver: expose _odr_type for filter cfgs 2024-10-10 17:25:29 +08:00
4f19d2c2be driver: Expose the upper and lower limit settings for Sinc3WithFineODR Filter Cfg 2024-10-10 15:23:57 +08:00
e8d3858fc9 driver: return whether task queue is full in task_dispatcher() 2024-10-10 15:20:58 +08:00
9bec56ed6c driver: Add support for GetPollInterval cmd 2024-10-10 15:19:43 +08:00
51b82e0447 cmd_handler: Add cmd to get temp adc polling interval 2024-10-10 13:41:15 +08:00
31e108a4b5 thermostat: settings obj now contains the exact filter type and val 2024-10-10 13:39:37 +08:00
253f4410ee sys_timer: Add fn to retrieve ts in us resolution 2024-10-10 13:31:20 +08:00
bd72c382b0 thermostat: Fix incorrect Dac Calibration Algo
- Thermostat Firmware repo PR #133
2024-10-08 15:57:18 +08:00
a512614de5 net: add option not to open sock when it is polled
- fix a bug, which mcu can get stuck in State::HardReset indefinitely
2024-09-11 17:54:23 +08:00
76f7875e3a gui: await for hard rst and dfu action 2024-09-11 17:54:23 +08:00
0d64d62fb0 gui: Add pd_mon config form
- force user to follow a sequence of steps for safely configuring pd_mon
2024-09-11 17:54:18 +08:00
0aeffdbf7b ld_pwr_exc_protector: disable irq after pwr off
-setting 0V threshold during power off might trigger IRQ
2024-09-11 17:05:38 +08:00
89a1270c02 driver: send cmd err msg to a pyqt sig 2024-09-11 17:05:38 +08:00
c2e78e6f17 driver: Support ApplyPdParams cmd
- Include handling mechanism for "InvalidSettings"b response msg
2024-09-11 17:05:38 +08:00
86e6d3764e laser: check pd_mon params & pwr limit before set
- Design to prevent Issue #47 on hardware kirdy repo from happening
- responsitivity, i_dark & transconductance determine the pwr limit range
- when "ApplyPdParams" and "SetLdPwrLimit" are called, pwr limit range
    is checked before applying new parameter
- Send out a "InvalidSettings" response with error message if settings
    cannot be applied
- Add settable power range to settings json object
2024-09-11 17:05:34 +08:00
1111967a7b gui: add arg for saving log to a file 2024-09-04 17:21:13 +08:00
1896e2534b main: Add PrepareForDfu state 2024-09-04 16:12:06 +08:00
6d4b1b0574 driver: end_session if ConnClose & Dfu is recv-ed 2024-09-04 16:10:42 +08:00
0b5fda2cd9 net: close oldest sock if available socks run out
- By default, smoltcp by default reset any new connections
    if there is no available socket
2024-09-04 15:46:43 +08:00
b763350a8b net: disable IRQ when data is being enqueued
- This prevents broken json to be sent out due to IRQ
2024-09-04 15:46:43 +08:00
838592c812 gui: Display hw_rev when connected 2024-09-04 15:46:43 +08:00
e632cbbfdd driver: use readuntil to get response msg
- The driver may recv partial ctrl msg, which causes a json decode error
2024-09-04 15:46:43 +08:00
27bf573010 driver: retrieve hw_rev after conn is established 2024-09-04 15:45:27 +08:00
c267c30b89 driver: add get_hw_rev() fn 2024-09-04 15:39:27 +08:00
c5826876a6 firmware: Add cmd to get hw_rev 2024-09-04 15:39:27 +08:00
6782cda790 Update pid autotuner code 2024-09-04 15:39:27 +08:00
2fe2ef531b Update example code 2024-09-04 15:39:27 +08:00
f2ad06ecae gui: patch the GUI code 2024-09-04 15:39:27 +08:00
5166bb7ba8 driver: rm thread use & make it asyncio callable
- make all cmds asyncio callable
- control specific cmds can be enqueued to the handler synchronously
2024-09-04 15:39:21 +08:00
9c611fc861 main: poll iface for dfu & hard rst ctrl msgs 2024-09-03 12:15:03 +08:00
51913f2e2f net: fix incorrect poll_iface() calls
- poll_iface might be called by interrupt while poll_iface was being called in main loop
- Disable interrupt when poll_iface is being processed
- Only use IfacePollTimer to poll_iface
2024-08-27 18:49:43 +08:00
c86d67b15c firmware: do not display smoltcp log 2024-08-27 18:49:43 +08:00
3d2294a90c driver: fix incorrect recv_response behavior 2024-08-27 18:49:13 +08:00
3ba8b99084 Use degree celsius as temperature base unit
- Breaking: Erase settings before flashing
- except beta in Steinhart-Hart equation
- to keep the temperature value set consistent with the value returned
- f32 floating point calculation is inaccurate
2024-08-07 17:36:12 +08:00
af73ac8127 gui: Add text for LD & Thermostat status 2024-08-07 12:48:12 +08:00