Hardware errata
Rev 1
- R307 needs more clearance from D400
- Pins 1 and 12 of U502 need pull-downs
- Pin 1 of U501 needs pull-up
- D203 reversed polarity
- R236 and R234 are swapped
- Q301 needs to be NPN, change to BC817
- increase R307 -> 3.3Kohm and increase R500 -> 33Kohm
- C201: oscillates at 0 and 1nF, stable at 100nF
- add clamp diodes to GND on op-amp outputs to ADC when op-amp has negative supply
- R214 -> 4.7k
- LM339PT is in TSSOP package. Change for SOIC P/N
- GDT200 minimum firing voltage is too low
- the relay model should be changed to 9001-05-00. 9001-05-02 is an undocumented normally closed variant.
- D504 should follow the schematics in its datasheet
- R502 should be connected to VCC
- R502 -> 240 ohm
- R234 -> 7.5k
- Q104 -> DMN3404
- R114 -> 470 ohm
- R115 -> 4.7k
- R227 -> 470 ohm
- R228 -> 4.7k
- review values of R226 and R113
- use crystal type recommended by the MCU datasheet
- fix filament voltage protection threshold
- 22k FBI current resistor -> 10k?
- add connector for OLED display?