3f7d8fdbf3
Fix unicode
2024-02-14 11:31:41 +08:00
938e3bd23f
i_set in front of measured current
2024-02-14 11:31:41 +08:00
355cb8360a
Move t_line setting to method, fixes 0°C bug
...
The 0 °C fix is an ugly one, ideally we should only update the label
when visibility returns.
2024-02-14 11:31:41 +08:00
0e02803b98
Adjust exit text
2024-02-14 11:31:41 +08:00
d119fd2275
Longer duration tooltip for zero limits warning
2024-02-14 11:31:41 +08:00
111742b809
Connect on enter press in the connection details
2024-02-14 11:31:41 +08:00
98d491203f
Add exit option in connection menu
2024-02-14 11:31:41 +08:00
7c1293e3d2
Number of channels generalisation
2024-02-14 11:31:41 +08:00
8cd1a70f50
variable name change
2024-02-14 11:31:41 +08:00
91a2cfb73e
Comment
2024-02-14 11:31:41 +08:00
da794080c6
More general activater
2024-02-14 11:31:41 +08:00
d8b1e7e964
Control Method simplifcation
2024-02-14 11:31:41 +08:00
c56a167824
Simplify postfilter stuff
2024-02-14 11:31:41 +08:00
bf0cb9ef05
Improve name
2024-02-14 11:31:41 +08:00
d60172d7eb
Set Limits Warning Fix
2024-02-14 11:31:41 +08:00
cb2fa36e68
No need for list now that params are all singular
2024-02-14 11:31:41 +08:00
470ea9edb3
Put PID output min and max into its own section
...
The critical difference between this and the max_i_pos, max_i_neg pair
is that output_max and output_min can have the same sign, meaning that
it is possible that PID current can be limited to positive values only.
2024-02-14 11:31:41 +08:00
99b40360c7
Remove siPrefixes for temperature units
2024-02-14 11:31:41 +08:00
83c14fb2de
Sync
2024-02-14 11:31:41 +08:00
2e8b26eb60
Show all current values in mA
...
Since the max and min is known as (-3A, 3A) on the thermostat TEC ports,
there is no need to use other SI prefix units.
2024-02-14 11:31:41 +08:00
5af14c26ea
Limit test current
2024-02-14 11:31:41 +08:00
da73f537b7
Separate min and max current
2024-02-14 11:31:41 +08:00
b4504bcfaa
Add docstring
2024-02-14 11:31:41 +08:00
fe6901d35f
Patch to avoid floating point error of temperature
...
A more complete system of dealing with floating point imprecision on the
way.
2024-02-14 11:31:41 +08:00
6005caf8b7
Add info boxes when loading/saving configs
2024-02-14 11:31:41 +08:00
442450667b
Status bar limits warning
2024-02-14 11:31:41 +08:00
e4d1f0133e
More decimals for current too
2024-02-14 11:31:41 +08:00
8fcd00292e
Add the rest of the modules
2024-02-14 11:31:41 +08:00
cfda30f795
Switch to pyproject.toml
2024-02-14 11:31:41 +08:00
ae70ce7e0b
Remove old GUI and update docs
2024-02-14 11:31:41 +08:00
333a759d85
Increase icon resolution
2024-02-14 11:31:41 +08:00
7ea9752b0f
Add window icon
2024-02-14 11:31:41 +08:00
9e96be30e9
Get rid of all translation things for now
2024-02-14 11:31:41 +08:00
933e1726c1
Correct units and stuff
2024-02-14 11:31:41 +08:00
1ff5a5d2b5
More decimals for temp
2024-02-14 11:31:41 +08:00
24006d17bf
Only log the autotuned params
2024-02-14 11:31:41 +08:00
a2c7b0b97a
Spinner
2024-02-14 11:31:41 +08:00
82dff9fc05
Remove bottom settings group tooltip
2024-02-14 11:31:41 +08:00
2231652cb2
Correct about thermostat var
2024-02-14 11:31:41 +08:00
37c0332c31
Legend names & order
2024-02-14 11:31:41 +08:00
4635e71ebf
Autotune
2024-02-14 11:31:41 +08:00
c9e8c4f4a1
Don't set_param that much
2024-02-14 11:31:41 +08:00
72956e19ee
No more _command
2024-02-14 11:31:41 +08:00
a213078c9a
Shorten channel to ch
2024-02-14 11:31:41 +08:00
4df651902a
Postfilter option revamped
2024-02-14 11:31:41 +08:00
1581aa4027
No private to slot
2024-02-14 11:31:41 +08:00
5c8ab769f3
Set param mroe
2024-02-14 11:31:41 +08:00
fe7bc5b7e5
Load config
2024-02-14 11:31:41 +08:00
5bb64e577f
Don't use _command
2024-02-14 11:31:41 +08:00
4caaf44f74
Both command and param
2024-02-14 11:31:41 +08:00