Commit Graph

478 Commits

Author SHA1 Message Date
7069111e21 Expose frontend scripts exclusively in pytec 2024-07-10 15:56:43 +08:00
1707728c3c thermostat_data_model.py -> thermostat.py 2024-07-10 15:56:34 +08:00
a16d2e9a9e Follow CapWords convention for class names
Re: PEP8
2024-07-10 15:45:03 +08:00
bc4ac43e0b Put comments in right place 2024-07-10 13:07:31 +08:00
9acff86547 Restructure GUI Code, Improve and Fix Bugs
- Bugs fix:
1. Params Tree user input will not get overwritten
    by incoming report thermostat_data_model.
2. PID Autotune Sampling Period is now set according to Thermostat sampling interval
3. PID Autotune won't get stuck in Fail State
4. Various types disconnection related Bugs
5. Number of Samples stored in the plot cannot be set
6. Limit the max settable output current to be 2000mA

- Improvement:
1. Params Tree settings can be changed with external json
2. Use a Tab system to show a single channel of config instead of two
3. Expose PID Autotune lookback params
4. Icon is changed to Artiq logo

- Restructure:
1. Restructure the code to follow Model-View-Delegate Design Pattern
2024-06-06 17:34:15 +08:00
8753f4a0fc Finish GUI 2024-05-08 14:49:03 +08:00
9a83d6850d Remove unused as clause 2024-05-08 14:49:03 +08:00
772863f4b2 Add paramtree view, without updates
Signed-off-by: Egor Savkin <es@m-labs.hk>

Fix signal blocker argument -atse
2024-05-08 14:49:03 +08:00
44ef2c04e3 Fix bugs, grammar, text, and refactor into class 2024-05-08 14:49:03 +08:00
623011fabb Change title 2024-05-08 14:49:03 +08:00
400f3a98e8 Stop polling drift
Just waiting for the update_s doesn't take into account the time to
execute update_params, and causes time drift.
2024-05-08 14:49:03 +08:00
7dd5d15047 Remove unused 'as' clause 2024-05-08 14:49:03 +08:00
297e589c30 Update docs 2024-05-08 14:49:03 +08:00
65e1f4a146 Finish moving over to qasync
Also:

* Add aioclient

The old client is synchronous and blocking, and the only way to achieve
true asynchronous IO is to create a new client that interfaces with
asyncio.

* Finish Nix Flake description and make the GUI available for `nix run`
2024-05-08 14:49:03 +08:00
e0ce14c616 Try move from Qthreads to qasync
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
a79679a074 Create client watcher, that would poll Thermostat for config
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
b9acba69d3 Create basic GUI, that would connect and control thermostat's fan
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
b4b4ec987c add autotune 2024-05-08 14:49:03 +08:00
8c1cb3117c README: Add notes on i_tec & tec_ireadouts 2024-05-02 17:48:47 +08:00
1fcfe41a63 Add averaging filter on the pin_adc readings
- Adapted from Kirdy Firmware
- Can reduce the i_tec readings noise dispersion
2024-05-02 16:49:55 +08:00
9fce19a418 Revert "Disable feedback current readout on flawed HW Revs"
This reverts commit ae3d8b51d4.
2024-05-02 14:38:40 +08:00
00d5feaa8d Limit i_set within range of MAX1968 chip 2024-04-24 18:05:20 +08:00
09be55e12a Don't load REF pin of MAX1968 chip on HWRevs < 3.0
The REF pin of the MAX1968 on hardware revisions v2.x is missing a
buffer, loading the pin on every CPU ADC read. Avoid reading from it and
leave the pin floating on affected hardware revisions, and return the
nominal 1.5V instead.
2024-04-03 16:32:57 +08:00
76547be90a i_tec -> i_set
i_tec is reserved for the voltage signal coming out of the MAX1968 chip
for now.
2024-02-14 17:27:12 +08:00
8b975e656e Stop i_set from fluctuating in every report
i_set is a user-provided value that shouldn't fluctuate with every VREF
measurement. Storing i_set as channel state is the simplest way to avoid
that.
2024-02-14 17:21:39 +08:00
ae3d8b51d4 Disable feedback current readout on flawed HW Revs
Thermostats v2.2 and below have a noisy and offset feedback current
`tec_i` caused by missing hardware on 2 MAX1968 TEC driver pins:

1. A missing RC filter on the ITEC pin that would have isolated CPU
sampling pulses from the signal; and
2. Some missing buffering on the VREF pin that would have avoided
loading the VREF signal, preventing voltage drops from the nominal 1.5V.

Since the resulting signal `tec_i` derived from these two signals can
have an error of around +/- 100mA, and readback may affect the stability
performance of the Thermostat, disable current readback entirely on
affected hardware revisions for now.

See https://github.com/sinara-hw/Thermostat/issues/117 and
https://github.com/sinara-hw/Thermostat/issues/120.

On hardware revisions v3.x and above, this would be fixed.
2024-01-31 12:12:22 +08:00
17edae44fb README: Proofread fan control documentation 2024-01-30 12:43:19 +08:00
03b4561142 Refactor current_abs_max_tec_i to use uom 2024-01-30 11:41:52 +08:00
631a10938d README: Remove VREF 2024-01-26 17:00:27 +08:00
6cd6a6a2c2 Fix warning '...not permit being left uninit..d'
Put SocketState initialisation logic in new. This avoids using an unsafe
and unnerving MaybeUninit::uninit().assume_init() to initialise an
array, which the compiler yells at since it causes undefined behavior.
2024-01-17 15:29:56 +08:00
b93e2fbb7b Update rust edition 2024-01-17 15:29:56 +08:00
76b95f66e0 Use latest working stable rust 2024-01-17 15:29:41 +08:00
8008870bc1 Switch panic_handler to panic_halt
Move away from panic_abort as it uses intrinsics, which is nightly only.
2024-01-17 15:29:15 +08:00
7646ff9037 README: Avoid deprecated OpenOCD ST-Link config
The config file interface/stlink-v2-1.cfg is deprecated, and the warning
message encourages the switch to interface/stlink.cfg. Do accordingly.
2024-01-04 12:44:52 +08:00
6f81a63d12 Remove unused LED parameters 2023-09-20 15:51:37 +08:00
78012f6fdd flake: Use rust from manifest, not from pkgs
Fix the rustPlatform deprecation warnings properly.
2023-09-20 11:29:38 +08:00
bb4f43fe1c Remove stale reference to channel_state vref 2023-08-22 17:16:25 +08:00
9df0fe406f Remove VREF in reports
Since VREF is an implementation detail, there shouldn't be a need to
include it in reports.

The ChannelState vref is removed along with it as its only use was to
save VREF measurements for later reporting.
2023-08-22 11:40:42 +08:00
5ba74c6d9b README: Correct expected TEC polarity
Adhere to the general convention of TECs cooling down with positive
voltages.
2023-08-15 16:37:51 +08:00
6f0acc73b8 Update LED L3 for PID status on every cycle
Check if PID is engaged on any channel every cycle, and match the status
with LED L3.
2023-08-10 16:43:19 +08:00
f29e86310d Update nix repos 2023-08-09 11:23:32 +08:00
b04a61c414 Turn off LED L3 only when all channels have no PID
Change the behaviour of LED L3 to turn off only when all channels have
PID disengaged, as opposed to when any channel disengages PID.

Otherwise, when disengaging PID on a Thermostat that has had both
channels engaged in PID, the LED would turn off, even when PID is still
engaged on the other channel.

This lets the LED better reflect the status of the Thermostat as a
whole, as it would stay on as long as PID is engaged on at least one
channel.
2023-08-07 16:09:54 +08:00
cd680dd6cd README: Correct unit of time in reports 2023-07-20 17:45:16 +08:00
e3e3237d2f Emit warning when current/voltage limits are near zero
Signed-off-by: Egor Savkin <es@m-labs.hk>
2023-03-23 16:58:05 +08:00
570c0324b3 implement support for fan PWM
Co-authored-by: Egor Savkin <es@m-labs.hk>
Co-committed-by: Egor Savkin <es@m-labs.hk>
2023-03-22 17:15:49 +08:00
5688b2f1bb flake: update stm32-eth sha256 hash 2022-03-02 17:21:17 +08:00
1b2f2f3888 update code to use stm32f4xx-hal 0.10.1 API 2022-03-02 17:21:17 +08:00
e6f63ec940 cargo/nix: update rustc, stm32-eth, smoltcp 2022-03-02 17:21:17 +08:00
67446ae99e cargo/flake: update package versions 2022-03-02 17:21:17 +08:00
26ad2f0119 rewrite PID
Rewrite of PID according to https://hackmd.io/IACbwcOTSt6Adj3_F9bKuw PID implementation.

To migrate:
- TEC+/- pin polarity has to be reversed.
- Some saved settings might be wiped upon flashing of new firmware, back up settings before upgrade
- Min / Max integral parameters no longer exist
- kp, ki, kd will likely need to be retuned

The software has been tested on hardware with good temperature control stability.

Reviewed-on: M-Labs/thermostat#68
Co-authored-by: topquark12 <aw@m-labs.hk>
Co-committed-by: topquark12 <aw@m-labs.hk>
2022-02-24 20:16:47 +08:00