Author SHA1 Message Date
26ad2f0119 rewrite PID
Rewrite of PID according to https://hackmd.io/IACbwcOTSt6Adj3_F9bKuw PID implementation.

To migrate:
- TEC+/- pin polarity has to be reversed.
- Some saved settings might be wiped upon flashing of new firmware, back up settings before upgrade
- Min / Max integral parameters no longer exist
- kp, ki, kd will likely need to be retuned

The software has been tested on hardware with good temperature control stability.

Reviewed-on: 
Co-authored-by: topquark12 <aw@m-labs.hk>
Co-committed-by: topquark12 <aw@m-labs.hk>
2022-02-24 20:16:47 +08:00
a5d8661b10 main: fix handling of incomplete data received ()
Reviewed-on: 
Co-Authored-By: topquark12 <aw@m-labs.hk>
Co-Committed-By: topquark12 <aw@m-labs.hk>
2021-01-29 16:18:07 +08:00
73dd6d9154 add PID autotune code
Co-Authored-By: topquark12 <aw@m-labs.hk>
Co-Committed-By: topquark12 <aw@m-labs.hk>
2021-01-06 11:02:52 +08:00