Commit Graph

97 Commits

Author SHA1 Message Date
0786fa0158 Put send_command in CtrlPanel 2024-10-07 13:27:48 +08:00
547700ac51 Extra bail removed 2024-10-07 13:24:02 +08:00
a76268a81f return hwrev when start_session 2024-10-07 13:24:02 +08:00
067ab925dd Stuff non-UI changes in Thermostat model 2024-10-07 13:24:01 +08:00
5bef8883e0 Base Thermostat connectivity UI changes to state 2024-10-07 13:24:01 +08:00
a19c64ce98 Remove wait_for
OSError raised anyways
2024-10-07 13:24:01 +08:00
22de1b623f Simplify on_connect_btn_clicked
Raise if OSError
2024-10-07 13:24:01 +08:00
e8387acbc9 Connecting task moved? 2024-10-07 13:24:01 +08:00
c4d31a78b1 Exclusively use the Thermostat object as a medium
All calls to the Thermostat should be forwarded by the medium.
2024-10-07 13:23:56 +08:00
047bde887e Integrate WrappedClient into Thermostat model 2024-10-07 13:22:55 +08:00
d4f46b994b Fix Autotuner state for forceful disconnect 2024-10-07 13:22:55 +08:00
b587a72345 Make connection loss handling more elegant
Show an info box on connection lost informing the user that the
Thermostat was forcefully disconnected.
2024-10-07 13:22:55 +08:00
88c3c6f815 Use new style super() 2024-10-07 13:22:55 +08:00
71d1c7390a Move command line host:port setting handling
To main
2024-10-07 13:22:55 +08:00
7f45437492 This is bail 2024-10-07 13:22:55 +08:00
958fddf953 ip -> host 2024-10-07 13:22:55 +08:00
05d46030b4 Add pytec runnables 2024-10-07 13:22:55 +08:00
38eb1c886d unused 2024-10-07 13:22:55 +08:00
1d4bc5c53f encoding 2024-10-07 13:22:55 +08:00
1ec541d580 Just catch asyncio.TimeoutError
Will just change to TimeoutError once we switch to Python 3.11 in the
flake.
2024-10-07 13:22:55 +08:00
abe08e4be6 Use asserts to check for connectivity 2024-10-07 13:22:55 +08:00
f77f5399cf Swap order arounda bit more 2024-10-07 13:22:55 +08:00
f632349c62 Formatting 2024-10-07 13:22:55 +08:00
41abad7aa3 send_command: Remove "activater"
Interpret commands anomalies directly in send_command instead
2024-08-14 16:07:15 +08:00
5c8d9c7cce send_command: Simplify "pid_autotune" parameters 2024-08-14 16:07:15 +08:00
278898fad2 send_command: Switch to thermostat:set_param
Use a `dict` to map values to thermostat parameters, which correspond to
the `set_param` parameters in the pytec client. New tag
"thermostat:set_param" used in JSON.
2024-08-14 16:07:14 +08:00
dd83daa5d9 send_command: Remove indirect path to parameter
The child at inner_param's childpath to the root parameter... is just
inner_param itself.
2024-08-14 16:06:31 +08:00
d57cc9ef2a send_command: Alias data as new_value 2024-08-14 16:06:24 +08:00
be77a6f205 send_command: Use in syntax 2024-08-14 16:06:17 +08:00
d244ba392a Fix typos 2024-07-19 15:34:31 +08:00
271fe449ba Remove duplicated show call
MainWindow.show() already called in coro_main
2024-07-10 15:56:43 +08:00
70db0a39eb Remove duplicated antialias config option
Already set in live_plot_view.py
2024-07-10 15:56:43 +08:00
26c7382b1e Move GUI components and examples into folder
For better organisation
2024-07-10 15:56:43 +08:00
1707728c3c thermostat_data_model.py -> thermostat.py 2024-07-10 15:56:34 +08:00
a16d2e9a9e Follow CapWords convention for class names
Re: PEP8
2024-07-10 15:45:03 +08:00
bc4ac43e0b Put comments in right place 2024-07-10 13:07:31 +08:00
9acff86547 Restructure GUI Code, Improve and Fix Bugs
- Bugs fix:
1. Params Tree user input will not get overwritten
    by incoming report thermostat_data_model.
2. PID Autotune Sampling Period is now set according to Thermostat sampling interval
3. PID Autotune won't get stuck in Fail State
4. Various types disconnection related Bugs
5. Number of Samples stored in the plot cannot be set
6. Limit the max settable output current to be 2000mA

- Improvement:
1. Params Tree settings can be changed with external json
2. Use a Tab system to show a single channel of config instead of two
3. Expose PID Autotune lookback params
4. Icon is changed to Artiq logo

- Restructure:
1. Restructure the code to follow Model-View-Delegate Design Pattern
2024-06-06 17:34:15 +08:00
8753f4a0fc Finish GUI 2024-05-08 14:49:03 +08:00
9a83d6850d Remove unused as clause 2024-05-08 14:49:03 +08:00
772863f4b2 Add paramtree view, without updates
Signed-off-by: Egor Savkin <es@m-labs.hk>

Fix signal blocker argument -atse
2024-05-08 14:49:03 +08:00
44ef2c04e3 Fix bugs, grammar, text, and refactor into class 2024-05-08 14:49:03 +08:00
400f3a98e8 Stop polling drift
Just waiting for the update_s doesn't take into account the time to
execute update_params, and causes time drift.
2024-05-08 14:49:03 +08:00
7dd5d15047 Remove unused 'as' clause 2024-05-08 14:49:03 +08:00
65e1f4a146 Finish moving over to qasync
Also:

* Add aioclient

The old client is synchronous and blocking, and the only way to achieve
true asynchronous IO is to create a new client that interfaces with
asyncio.

* Finish Nix Flake description and make the GUI available for `nix run`
2024-05-08 14:49:03 +08:00
e0ce14c616 Try move from Qthreads to qasync
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
a79679a074 Create client watcher, that would poll Thermostat for config
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
b9acba69d3 Create basic GUI, that would connect and control thermostat's fan
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00