# Firmware for the Sinara 8451 Thermostat
|
|
|
|
- [x] [Continuous Integration](https://nixbld.m-labs.hk/job/stm32/stm32/thermostat)
|
|
- [x] [Download latest firmware build](https://nixbld.m-labs.hk/job/stm32/stm32/thermostat/latest/download-by-type/file/binary-dist)
|
|
|
|
|
|
## Building
|
|
|
|
### Debian-based systems (tested on Ubuntu 19.10)
|
|
|
|
- install git, clone this repository
|
|
- install [rustup](https://rustup.rs/)
|
|
|
|
```shell
|
|
rustup toolchain install nightly
|
|
rustup update
|
|
rustup target add thumbv7em-none-eabihf --toolchain nightly
|
|
rustup default nightly
|
|
cargo build --release
|
|
```
|
|
|
|
The resulting ELF file will be located under `target/thumbv7em-none-eabihf/release/thermostat`
|
|
|
|
|
|
## Network
|
|
|
|
### Connecting
|
|
|
|
Ethernet, IP: 192.168.1.26/24
|
|
|
|
Use netcat to connect to port 23/tcp (telnet)
|
|
```sh
|
|
nc -vv 192.168.1.26 23
|
|
```
|
|
|
|
telnet clients send binary data after connect. Enter \n once to
|
|
invalidate the first line of input.
|
|
|
|
|
|
### Reading ADC input
|
|
|
|
Set report mode to `on` for a continuous stream of input data.
|
|
|
|
The scope of this setting is per TCP session.
|
|
|
|
|
|
### Commands
|
|
|
|
| Syntax | Function |
|
|
| --- | --- |
|
|
| `report` | Show current input |
|
|
| `report mode` | Show current report mode |
|
|
| `report mode <off/on>` | Set report mode |
|
|
| `pwm` | Show current PWM settings |
|
|
| `pwm <0/1> max_i_pos <ratio>` | Set PWM duty cycle for **max_i_pos** to *ampere* |
|
|
| `pwm <0/1> max_i_neg <ratio>` | Set PWM duty cycle for **max_i_neg** to *ampere* |
|
|
| `pwm <0/1> max_v <ratio>` | Set PWM duty cycle for **max_v** to *volt* |
|
|
| `pwm <0/1> <volts>` | Disengage PID, set **i_set** DAC to *ampere* |
|
|
| `pwm <0/1> pid` | Set PWM to be controlled by PID |
|
|
| `center <0/1> <volts>` | Set the MAX1968 0A-centerpoint to *volts* |
|
|
| `center <0/1> vref` | Set the MAX1968 0A-centerpoint to measure from VREF |
|
|
| `pid` | Show PID configuration |
|
|
| `pid <0/1> target <value>` | Set the PID controller target |
|
|
| `pid <0/1> kp <value>` | Set proportional gain |
|
|
| `pid <0/1> ki <value>` | Set integral gain |
|
|
| `pid <0/1> kd <value>` | Set differential gain |
|
|
| `pid <0/1> output_min <value>` | Set mininum output |
|
|
| `pid <0/1> output_max <value>` | Set maximum output |
|
|
| `pid <0/1> integral_min <value>` | Set integral lower bound |
|
|
| `pid <0/1> integral_max <value>` | Set integral upper bound |
|
|
| `s-h` | Show Steinhart-Hart equation parameters |
|
|
| `s-h <0/1> <t/b/r0> <value>` | Set Steinhart-Hart parameter for a channel |
|
|
| `postfilter <0/1> rate <rate>` | Set postfilter output data rate |
|
|
| `load` | Restore configuration from EEPROM |
|
|
| `save` | Save configuration to EEPROM |
|
|
| `reset` | Reset the device |
|