@ -36,9 +36,9 @@ Below are some general guidelines for manually tuning PID loops. Note that every
1. To start the manual tuning process, set the kp, ki and kd parameters to 0.
2. Begin by increasing kP until the temperature begins to oscillate. Offset between the target temperature and the actual temperature can be ignored for now.
2. Begin by increasing kp until the temperature begins to oscillate. Offset between the target temperature and the actual temperature can be ignored for now.
3. Reduce kP by 30%, increase ki until the offset between target and actual temperature is eliminated.
3. Reduce kp by 30%, increase ki until the offset between target and actual temperature is eliminated.
4. Increase kd until the maximum allowable amount of overshoot is observed.
@ -60,11 +60,11 @@ After some time, the auto tuning utility will output the auto tuning results, be
Ku: 0.7553203471147422
Pu: 75.93899999999977
rule: ziegler-nichols
Kp: 0.45319220826884526
kp: 0.45319220826884526
Ki: 0.011935690706194357
Kd: 4.301870387965967
rule: tyreus-luyben
Kp: 0.3432930977636503
kp: 0.3432930977636503
Ki: 0.0020549280832497956
Kd: 4.137825730504864
.