forked from M-Labs/artiq
368 lines
12 KiB
ReStructuredText
368 lines
12 KiB
ReStructuredText
.. Add new releases at the top to keep important stuff directly visible.
|
||
|
||
Release notes
|
||
=============
|
||
|
||
ARTIQ-5
|
||
-------
|
||
|
||
5.0
|
||
***
|
||
|
||
* The :class:`~artiq.coredevice.ad9910.AD9910` and
|
||
:class:`~artiq.coredevice.ad9914.AD9914` phase reference timestamp parameters
|
||
have been renamed to ``ref_time_mu`` for consistency, as they are in machine
|
||
units.
|
||
* :func:`~artiq.tools.verbosity_args` renamed to :func:`~artiq.tools.add_common_args`. New feature: adds an option to print the ARTIQ version.
|
||
* A gateware-level input edge counter has been added, which offers higher
|
||
throughput and increased flexibility over the usual TTL input PHYs where
|
||
edge timestamps are not required. See :mod:`artiq.coredevice.edge_counter` for
|
||
the core device driver and :mod:`artiq.gateware.rtio.phy.edge_counter`/
|
||
:meth:`artiq.gateware.eem.DIO.add_std` for the gateware components.
|
||
|
||
|
||
ARTIQ-4
|
||
-------
|
||
|
||
4.0
|
||
***
|
||
|
||
* The ``artiq.coredevice.ttl`` drivers no longer track the timestamps of
|
||
submitted events in software, requiring the user to explicitly specify the
|
||
timeout for ``count()``/``timestamp_mu()``. Support for ``sync()`` has been dropped.
|
||
|
||
Now that RTIO has gained DMA support, there is no longer a reliable way for
|
||
the kernel CPU to track the individual events submitted on any one channel.
|
||
Requiring the timeouts to be specified explicitly ensures consistent API
|
||
behavior. To make this more convenient, the ``TTLInOut.gate_*()`` functions
|
||
now return the cursor position at the end of the gate, e.g.::
|
||
|
||
ttl_input.count(ttl_input.gate_rising(100 * us))
|
||
|
||
In most situations – that is, unless the timeline cursor is rewound after the
|
||
respective ``gate_*()`` call – simply passing ``now_mu()`` is also a valid
|
||
upgrade path::
|
||
|
||
ttl_input.count(now_mu())
|
||
|
||
The latter might use up more timeline slack than necessary, though.
|
||
|
||
In place of ``TTL(In)Out.sync``, the new ``Core.wait_until_mu()`` method can
|
||
be used, which blocks execution until the hardware RTIO cursor reaches the
|
||
given timestamp::
|
||
|
||
ttl_output.pulse(10 * us)
|
||
self.core.wait_until_mu(now_mu())
|
||
* RTIO outputs use a new architecture called Scalable Event Dispatcher (SED),
|
||
which allows building systems with large number of RTIO channels more
|
||
efficiently.
|
||
From the user perspective, collision errors become asynchronous, and non-
|
||
monotonic timestamps on any combination of channels are generally allowed
|
||
(instead of producing sequence errors).
|
||
RTIO inputs are not affected.
|
||
* The DDS channel number for the NIST CLOCK target has changed.
|
||
* The dashboard configuration files are now stored one-per-master, keyed by the
|
||
server address argument and the notify port.
|
||
* The master now has a ``--name`` argument. If given, the dashboard is labelled
|
||
with this name rather than the server address.
|
||
* ``artiq_flash`` targets Kasli by default. Use ``-t kc705`` to flash a KC705
|
||
instead.
|
||
* ``artiq_flash -m/--adapter`` has been changed to ``artiq_flash -V/--variant``.
|
||
* The ``proxy`` action of ``artiq_flash`` is determined automatically and should
|
||
not be specified manually anymore.
|
||
* ``kc705_dds`` has been renamed ``kc705``.
|
||
* The ``-H/--hw-adapter`` option of ``kc705`` has been renamed ``-V/--variant``.
|
||
* SPI masters have been switched from misoc-spi to misoc-spi2. This affects
|
||
all out-of-tree RTIO core device drivers using those buses. See the various
|
||
commits on e.g. the ``ad53xx`` driver for an example how to port from the old
|
||
to the new bus.
|
||
* The ``ad5360`` coredevice driver has been renamed to ``ad53xx`` and the API
|
||
has changed to better support Zotino.
|
||
* ``artiq.coredevice.dds`` has been renamed to ``artiq.coredevice.ad9914`` and
|
||
simplified. DDS batch mode is no longer supported. The ``core_dds`` device
|
||
is no longer necessary.
|
||
* The configuration entry ``startup_clock`` is renamed ``rtio_clock``. Switching
|
||
clocks dynamically (i.e. without device restart) is no longer supported.
|
||
* ``set_dataset(..., save=True)`` has been renamed
|
||
``set_dataset(..., archive=True)``.
|
||
* On the AD9914 DDS, when switching to ``PHASE_MODE_CONTINUOUS`` from another mode,
|
||
use the returned value of the last ``set_mu`` call as the phase offset for
|
||
``PHASE_MODE_CONTINUOUS`` to avoid a phase discontinuity. This is no longer done
|
||
automatically. If one phase glitch when entering ``PHASE_MODE_CONTINUOUS`` is not
|
||
an issue, this recommendation can be ignored.
|
||
|
||
|
||
ARTIQ-3
|
||
-------
|
||
|
||
3.7
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
3.6
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
3.5
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
3.4
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
3.3
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
3.2
|
||
***
|
||
|
||
* To accommodate larger runtimes, the flash layout as changed. As a result, the
|
||
contents of the flash storage will be lost when upgrading. Set the values back
|
||
(IP, MAC address, startup kernel, etc.) after the upgrade.
|
||
|
||
|
||
3.1
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
3.0
|
||
***
|
||
|
||
* The ``--embed`` option of applets is replaced with the environment variable
|
||
``ARTIQ_APPLET_EMBED``. The GUI sets this enviroment variable itself and the
|
||
user simply needs to remove the ``--embed`` argument.
|
||
* ``EnvExperiment``'s ``prepare`` calls ``prepare`` for all its children.
|
||
* Dynamic ``__getattr__``'s returning RPC target methods are not supported anymore.
|
||
Controller driver classes must define all their methods intended for RPC as
|
||
members.
|
||
* Datasets requested by experiments are by default archived into their HDF5
|
||
output. If this behavior is undesirable, turn it off by passing
|
||
``archive=False`` to ``get_dataset``.
|
||
* ``seconds_to_mu`` and ``mu_to_seconds`` have become methods of the core
|
||
device driver (use e.g. ``self.core.seconds_to_mu()``).
|
||
* AD9858 DDSes and NIST QC1 hardware are no longer supported.
|
||
* The DDS class names and setup options have changed, this requires an update of
|
||
the device database.
|
||
* ``int(a, width=b)`` has been removed. Use ``int32(a)`` and ``int64(a)``.
|
||
* The KC705 gateware target has been renamed ``kc705_dds``.
|
||
* ``artiq.coredevice.comm_tcp`` has been renamed ``artiq.coredevice.comm_kernel``,
|
||
and ``Comm`` has been renamed ``CommKernel``.
|
||
* The "collision" and "busy" RTIO errors are reported through the log instead of
|
||
raising exceptions.
|
||
* Results are still saved when ``analyze`` raises an exception.
|
||
* ``LinearScan`` and ``RandomScan`` have been consolidated into RangeScan.
|
||
* The Pipistrello is no longer supported. For a low-cost ARTIQ setup, use either
|
||
ARTIQ 2.x with Pipistrello, or the future ARTIQ 4.x with Kasli. Note that the
|
||
Pipistrello board has also been discontinued by the manufacturer but its design
|
||
files are freely available.
|
||
* The device database is now generated by an executable Python script. To migrate
|
||
an existing database, add ``device_db = `` at the beginning, and replace any PYON
|
||
identifiers (``true``, ``null``, ...) with their Python equivalents
|
||
(``True``, ``None`` ...).
|
||
* Controllers are now named ``aqctl_XXX`` instead of ``XXX_controller``.
|
||
* In the device database, the ``comm`` device has been folded into the ``core`` device.
|
||
Move the "host" argument into the ``core`` device, and remove the ``comm`` device.
|
||
* The core device log now contains important information about events such as
|
||
RTIO collisions. A new controller ``aqctl_corelog`` must be running to forward
|
||
those logs to the master. See the example device databases to see how to
|
||
instantiate this controller. Using ``artiq_session`` ensures that a controller
|
||
manager is running simultaneously with the master.
|
||
* Experiments scheduled with the "flush pipeline" option now proceed when there
|
||
are lower-priority experiments in the pipeline. Only experiments at the current
|
||
(or higher) priority level are flushed.
|
||
* The PDQ(2/3) driver has been removed and is now being maintained out-of tree
|
||
at https://github.com/m-labs/pdq. All SPI/USB driver layers, Mediator,
|
||
CompoundPDQ and examples/documentation has been moved.
|
||
* The master now rotates log files at midnight, rather than based on log size.
|
||
* The results keys ``start_time`` and ``run_time`` are now stored as doubles of UNIX time,
|
||
rather than ints. The file names are still based on local time.
|
||
* Packages are no longer available for 32-bit Windows.
|
||
|
||
|
||
ARTIQ-2
|
||
-------
|
||
|
||
2.5
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
2.4
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
2.3
|
||
***
|
||
|
||
* When using conda, add the conda-forge channel before installing ARTIQ.
|
||
|
||
|
||
2.2
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
2.1
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
2.0
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
2.0rc2
|
||
******
|
||
|
||
No further notes.
|
||
|
||
|
||
2.0rc1
|
||
******
|
||
|
||
* The format of the influxdb pattern file is simplified. The procedure to
|
||
edit patterns is also changed to modifying the pattern file and calling:
|
||
``artiq_rpctool.py ::1 3248 call scan_patterns`` (or restarting the bridge)
|
||
The patterns can be converted to the new format using this code snippet::
|
||
|
||
from artiq.protocols import pyon
|
||
patterns = pyon.load_file("influxdb_patterns.pyon")
|
||
for p in patterns:
|
||
print(p)
|
||
|
||
* The "GUI" has been renamed the "dashboard".
|
||
* When flashing NIST boards, use "-m nist_qcX" or "-m nist_clock" instead of
|
||
just "-m qcX" or "-m clock" (#290).
|
||
* Applet command lines now use templates (e.g. $python) instead of formats
|
||
(e.g. {python}).
|
||
* On Windows, GUI applications no longer open a console. For debugging
|
||
purposes, the console messages can still be displayed by running the GUI
|
||
applications this way::
|
||
|
||
python3.5 -m artiq.frontend.artiq_browser
|
||
python3.5 -m artiq.frontend.artiq_dashboard
|
||
|
||
(you may need to replace python3.5 with python)
|
||
Please always include the console output when reporting a GUI crash.
|
||
* The result folders are formatted "%Y-%m-%d/%H instead of "%Y-%m-%d/%H-%M".
|
||
(i.e. grouping by day and then by hour, instead of by day and then by minute)
|
||
* The ``parent`` keyword argument of ``HasEnvironment`` (and ``EnvExperiment``)
|
||
has been replaced. Pass the parent as first argument instead.
|
||
* During experiment examination (and a fortiori repository scan), the values of
|
||
all arguments are set to ``None`` regardless of any default values supplied.
|
||
* In the dashboard's experiment windows, partial or full argument recomputation
|
||
takes into account the repository revision field.
|
||
* By default, ``NumberValue`` and ``Scannable`` infer the scale from the unit
|
||
for common units.
|
||
* By default, artiq_client keeps the current persist flag on the master.
|
||
* GUI state files for the browser and the dashboard are stores in "standard"
|
||
locations for each operating system. Those are
|
||
``~/.config/artiq/2/artiq_*.pyon`` on Linux and
|
||
``C:\Users\<username>\AppData\Local\m-labs\artiq\2\artiq_*.pyon`` on
|
||
Windows 7.
|
||
* The position of the time cursor is kept across experiments and RTIO resets
|
||
are manual and explicit (inter-experiment seamless handover).
|
||
* All integers manipulated by kernels are numpy integers (numpy.int32,
|
||
numpy.int64). If you pass an integer as a RPC argument, the target function
|
||
receives a numpy type.
|
||
|
||
|
||
ARTIQ-1
|
||
-------
|
||
|
||
1.3
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
1.2
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
1.1
|
||
***
|
||
|
||
* TCA6424A.set converts the "outputs" value to little-endian before programming
|
||
it into the registers.
|
||
|
||
|
||
1.0
|
||
***
|
||
|
||
No further notes.
|
||
|
||
|
||
1.0rc4
|
||
******
|
||
|
||
* setattr_argument and setattr_device add their key to kernel_invariants.
|
||
|
||
|
||
1.0rc3
|
||
******
|
||
|
||
* The HDF5 format has changed.
|
||
|
||
* The datasets are located in the HDF5 subgroup ``datasets``.
|
||
* Datasets are now stored without additional type conversions and annotations
|
||
from ARTIQ, trusting that h5py maps and converts types between HDF5 and
|
||
python/numpy "as expected".
|
||
|
||
* NumberValue now returns an integer if ``ndecimals`` = 0, ``scale`` = 1 and
|
||
``step`` is integer.
|
||
|
||
|
||
1.0rc2
|
||
******
|
||
|
||
* The CPU speed in the pipistrello gateware has been reduced from 83 1/3 MHz to
|
||
75 MHz. This will reduce the achievable sustained pulse rate and latency
|
||
accordingly. ISE was intermittently failing to meet timing (#341).
|
||
* set_dataset in broadcast mode no longer returns a Notifier. Mutating datasets
|
||
should be done with mutate_dataset instead (#345).
|
||
|
||
|
||
1.0rc1
|
||
******
|
||
|
||
* Experiments (your code) should use ``from artiq.experiment import *``
|
||
(and not ``from artiq import *`` as previously)
|
||
* Core device flash storage has moved due to increased runtime size.
|
||
This requires reflashing the runtime and the flash storage filesystem image
|
||
or erase and rewrite its entries.
|
||
* ``RTIOCollisionError`` has been renamed to ``RTIOCollision``
|
||
* the new API for DDS batches is::
|
||
|
||
with self.core_dds.batch:
|
||
...
|
||
|
||
with ``core_dds`` a device of type ``artiq.coredevice.dds.CoreDDS``.
|
||
The dds_bus device should not be used anymore.
|
||
* LinearScan now supports scanning from high to low. Accordingly,
|
||
its arguments ``min/max`` have been renamed to ``start/stop`` respectively.
|
||
Same for RandomScan (even though there direction matters little).
|