forked from M-Labs/artiq
drtio: add support for 125MHz clock on GTX_1000BASE_BX10
This commit is contained in:
parent
95def81c03
commit
7c05dccf65
|
@ -10,7 +10,10 @@ from artiq.gateware.drtio.transceiver.gtx_7series_init import *
|
|||
class GTX_1000BASE_BX10(Module):
|
||||
rtio_clk_freq = 62.5e6
|
||||
|
||||
def __init__(self, clock_pads, tx_pads, rx_pads, sys_clk_freq):
|
||||
# The transceiver clock on clock_pads must be 62.5MHz
|
||||
# when clock_div2=False, and 125MHz when clock_div2=True.
|
||||
def __init__(self, clock_pads, tx_pads, rx_pads, sys_clk_freq,
|
||||
clock_div2=False):
|
||||
self.submodules.encoder = ClockDomainsRenamer("rtio")(
|
||||
Encoder(2, True))
|
||||
self.decoders = [ClockDomainsRenamer("rtio_rx")(
|
||||
|
@ -23,6 +26,14 @@ class GTX_1000BASE_BX10(Module):
|
|||
# # #
|
||||
|
||||
refclk = Signal()
|
||||
if clock_div2:
|
||||
self.specials += Instance("IBUFDS_GTE2",
|
||||
i_CEB=0,
|
||||
i_I=clock_pads.p,
|
||||
i_IB=clock_pads.n,
|
||||
o_ODIV2=refclk
|
||||
)
|
||||
else:
|
||||
self.specials += Instance("IBUFDS_GTE2",
|
||||
i_CEB=0,
|
||||
i_I=clock_pads.p,
|
||||
|
|
Loading…