forked from M-Labs/artiq
urukul: document consequences of incorrect CPLD clock settings
This commit is contained in:
parent
adf3df2bb5
commit
74e4b01201
|
@ -154,6 +154,10 @@ class CPLD:
|
|||
RTIO frequency and the SYNC_IN generator frequency (default: 2 if
|
||||
`sync_device` was specified).
|
||||
:param core_device: Core device name
|
||||
|
||||
If the clocking is incorrect (for example, setting ``clk_sel`` to the
|
||||
front panel SMA with no clock connected), then the ``init()`` method of
|
||||
the DDS channels can fail with the error message ``PLL lock timeout``.
|
||||
"""
|
||||
kernel_invariants = {"refclk", "bus", "core", "io_update", "clk_div"}
|
||||
|
||||
|
|
Loading…
Reference in New Issue