Prefer DHCP to the built-in static IPs

Signed-off-by: Michael Birtwell <michael.birtwell@oxionics.com>
This commit is contained in:
Michael Birtwell 2022-01-14 16:52:23 +00:00 committed by Sebastien Bourdeauducq
parent 6ffb1f83ee
commit 596b9a265c
3 changed files with 8 additions and 16 deletions

View File

@ -42,7 +42,8 @@ Highlights:
* ``PCA9548`` I2C switch class renamed to ``I2CSwitch``, to accomodate support for PCA9547, and
possibly other switches in future. Readback has been removed, and now only one channel per
switch is supported.
* The "ip" config option can now be set to "use_dhcp" to use DHCP to obtain an IP address.
* The "ip" config option can now be set to "use_dhcp" in order to use DHCP to obtain an IP address.
DHCP will also be used if no "ip" config option is set.
Breaking changes:

View File

@ -60,16 +60,7 @@ pub fn get_adresses() -> NetAddresses {
}
})) {
Ok(Ok(addr)) => ipv4_addr = addr,
_ => {
#[cfg(soc_platform = "kasli")]
{ ipv4_addr = IpAddress::v4(192, 168, 1, 70); }
#[cfg(soc_platform = "sayma_amc")]
{ ipv4_addr = IpAddress::v4(192, 168, 1, 60); }
#[cfg(soc_platform = "metlino")]
{ ipv4_addr = IpAddress::v4(192, 168, 1, 65); }
#[cfg(soc_platform = "kc705")]
{ ipv4_addr = IpAddress::v4(192, 168, 1, 50); }
}
_ => ipv4_addr = USE_DHCP,
}
let ipv6_ll_addr = IpAddress::v6(

View File

@ -261,18 +261,18 @@ If you purchased a Kasli device from M-Labs, it usually comes with the IP addres
and then reboot the device (with ``artiq_flash start`` or a power cycle).
In other cases, install OpenOCD as before, and flash the IP (and, if necessary, MAC) addresses directly: ::
If the ip config field is not set, or set to "use_dhcp" then the device will attempt to obtain an IP address using
DHCP. If a static IP address is wanted, install OpenOCD as before, and flash the IP (and, if necessary, MAC) addresses
directly: ::
$ artiq_mkfs flash_storage.img -s mac xx:xx:xx:xx:xx:xx -s ip xx.xx.xx.xx
$ artiq_flash -t [board] -V [variant] -f flash_storage.img storage start
For Kasli devices, flashing a MAC address is not necessary as they can obtain it from their EEPROM.
Alternatively you can set the "ip" config field to "use_dhcp" to have the device use DHCP to obtain an IP address on
boot. e.g. ::
If DHCP has been used the address can be found in the console output, which can be viewed using: ::
$ artiq_mkfs flash_storage.img -s ip use_dhcp
$ artiq_flash -t [board] -V [variant] -f flash_storage.img storage start
$ python -m misoc.tools.flterm /dev/ttyUSB2
Check that you can ping the device. If ping fails, check that the Ethernet link LED is ON - on Kasli, it is the LED next to the SFP0 connector. As a next step, look at the messages emitted on the UART during boot. Use a program such as flterm or PuTTY to connect to the device's serial port at 115200bps 8-N-1 and reboot the device. On Kasli, the serial port is on FTDI channel 2 with v1.1 hardware (with channel 0 being JTAG) and on FTDI channel 1 with v1.0 hardware.