forked from M-Labs/artiq
1
0
Fork 0

Lda: sanity checks on attenuation value

- Plus use of dB unit
This commit is contained in:
Yann Sionneau 2015-01-09 15:09:17 +01:00 committed by Sebastien Bourdeauducq
parent d21211a473
commit 2ad063c377
2 changed files with 47 additions and 6 deletions

View File

@ -1,7 +1,7 @@
import logging import logging
import ctypes import ctypes
import struct import struct
from artiq.language.units import dB, check_unit, Quantity
logger = logging.getLogger("lda") logger = logging.getLogger("lda")
@ -16,6 +16,8 @@ class Ldasim:
def __init__(self): def __init__(self):
self._attenuation = None self._attenuation = None
self._att_max = 63*dB
self._att_step_size = 0.25*dB
def get_attenuation(self): def get_attenuation(self):
"""Reads last attenuation value set to the simulated device. """Reads last attenuation value set to the simulated device.
@ -34,9 +36,23 @@ class Ldasim:
:type attenuation: int, float or Fraction :type attenuation: int, float or Fraction
""" """
attenuation = round(attenuation*4)/4. if isinstance(attenuation, Quantity):
print("[LDA-sim] setting attenuation to {}".format(attenuation)) check_unit(attenuation, 'dB')
self._attenuation = attenuation else:
att = attenuation*dB
if att > self._att_max:
raise ValueError('Cannot set attenuation {} > {}'
.format(att, self._att_max))
elif att < 0*dB:
raise ValueError('Cannot set attenuation {} < 0'.format(att))
elif att % self._att_step_size != 0*dB:
raise ValueError('Cannot set attenuation {} with step size {}'
.format(att, self._att_step_size))
else:
att = round(att.amount*4)/4. * dB
print("[LDA-sim] setting attenuation to {}".format(att))
self._attenuation = att
class Lda: class Lda:
@ -59,6 +75,16 @@ class Lda:
"LDA-602": 0x1208, "LDA-602": 0x1208,
"LDA-302P-1": 0x120E, "LDA-302P-1": 0x120E,
} }
_max_att = {
"LDA-102": 63*dB,
"LDA-602": 63*dB,
"LDA-302P-1": 63*dB
}
_att_step_size = {
"LDA-102": 0.5*dB,
"LDA-602": 0.5*dB,
"LDA-302P-1": 1.0*dB
}
def __init__(self, serial=None, product="LDA-102"): def __init__(self, serial=None, product="LDA-102"):
""" """
@ -149,7 +175,7 @@ class Lda:
:rtype: float :rtype: float
""" """
return ord(self.get(0x0d, 1))/4. return (ord(self.get(0x0d, 1))/4.) * dB
def set_attenuation(self, attenuation): def set_attenuation(self, attenuation):
"""Sets attenuation value of the Lab Brick device. """Sets attenuation value of the Lab Brick device.
@ -158,4 +184,18 @@ class Lda:
:type attenuation: int, float or Fraction :type attenuation: int, float or Fraction
""" """
self.set(0x8d, bytes([int(round(attenuation*4))])) if isinstance(attenuation, Quantity):
check_unit(attenuation, 'dB')
else:
att = attenuation*dB
if att > self._max_att[self.product]:
raise ValueError('Cannot set attenuation {} > {}'
.format(att, self._max_att[self.product]))
elif att < 0:
raise ValueError('Cannot set attenuation {} < 0'.format(att))
elif att % self._att_step_size[self.product] != 0:
raise ValueError('Cannot set attenuation {} with {} step size'
.format(att, self._att_step_size[self.product]))
else:
self.set(0x8d, bytes([int(round(att.amount*4))]))

View File

@ -208,6 +208,7 @@ def _register_unit(unit, prefixes):
_register_unit("s", "pnum_") _register_unit("s", "pnum_")
_register_unit("Hz", "_kMG") _register_unit("Hz", "_kMG")
_register_unit("dB", "_")
def check_unit(value, unit): def check_unit(value, unit):