[Rev0_2] Wrong MFR_PN is set #28
linuswck
commented 2023-11-09 17:44:06 +08:00
Member
- 10u Capacitors that connects to the 15V rail should have a higher voltage rating(org: 16V)
- All 100R has a wrong set of Part number that has 300R resistance
- 90.9k Resistor has wrong Alternate P/N with wrong resistance value(9.09k instead of 90.9k)
1. 10u Capacitors that connects to the 15V rail should have a higher voltage rating(org: 16V)
2. All 100R has a wrong set of Part number that has 300R resistance
3. 90.9k Resistor has wrong Alternate P/N with wrong resistance value(9.09k instead of 90.9k)
linuswck
referenced a pull request that will close this issue 2023-11-10 15:37:20 +08:00
Kirdy Revision 0_3 #23
sb10q
closed this issue 2023-12-19 18:30:33 +08:00
Loading…
Reference in New Issue
No description provided.
Delete Branch "%!s(<nil>)"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?