[TEST] Turn on / Turn off behavior #20
Loading…
Reference in New Issue
Block a user
No description provided.
Delete Branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Laser Driver Output
Objective
To see if there is current spikes appear on the laser driver output at startup and check if abnormal behavior
Test Setup
Kirdy Hardware: Rev0_2
Kirdy Adapter: Rev0_1 Type 1
Firmware:
285fc9b5d6
Power Supply: Rigol DP832
Stimulus Source:
Point of Measurement:
Blue
Purple
Result
There is no current spike at laser driver output during power on and power off
Power On
Note: There is charges left on the capacitor at 8V Power Rail in previous bootup. Therefore, LD- voltage is initially pull down to GND. Please see boot sequence.
Power Off
Laser Driver Output (Without Load)
Objective
To check open circuit voltage
Test Setup
Kirdy Hardware: Rev0_2
Kirdy Adapter: Rev0_1 Type 1
Firmware:
285fc9b5d6
Power Supply: Rigol DP832
Stimulus Source:
Point of Measurement:
Blue
Yellow(LD+) and Purple(LD-)
Result
There is no current spike at laser driver output during power on and power off
Power On
Note: There is charges left on the capacitor at 8V Power Rail in previous bootup. Therefore, LD- voltage is initially pull down to GND. Please see boot sequence.
Power Off
Note: At power off, there would not be enough current driving the relay. Thus, LD+ and LD- are eventually shorted together in the relay.