Compare commits

..

1 Commits

Author SHA1 Message Date
2428dadf00 1008: init 2025-01-10 13:40:14 +01:00
6 changed files with 88 additions and 97 deletions

88
1008.tex Normal file
View File

@ -0,0 +1,88 @@
\input{preamble.tex}
\graphicspath{{images/1008}{images}}
\title{1008 VHDCI Carrier}
\author{M-Labs Limited}
\date{January 2025}
\revision{Revision 1}
\companylogo{\includegraphics[height=0.73in]{artiq_sinara.pdf}}
\begin{document}
\maketitle
\section{Features}
\begin{itemize}
\item{8 channels}
\item{8 internal EEM connectors}
\item{2 external VHDCI connectors}
\end{itemize}
\section{Applications}
\begin{itemize}
\item{Break out VHDCI to extension boards}
\item{Carry signals over VHDCI between crates}
\item{Low-cost alternative to DRTIO}
\item{Adapter for certain KC705 ARTIQ systems}
\end{itemize}
\section{General Description}
The 1008 VHDCI Carrier is a 4hp EEM module, part of the ARTIQ/Sinara family. It is a passive adapter card which converts VHDCI connections to or from EEM connections.
The 1008 VHDCI Carrier is bidirectional; it can be driven by a core device carrier board, or can drive other cards.
A pair of VHDCI Carrier cards can be paired with VHDCI SCSI-3 cables to carry EEM signals over short distances between crates. Depending on the application, this can serve as a simple, low-cost, low-latency alternative to multiple core devices and ARTIQ DRTIO.
% Switch to next column
\vfill\break
%\begin{figure}[h]
% \centering
% \scalebox{1.15}{
% \begin{circuitikz}[european, every label/.append style={align=center}]
% \begin{scope}[]
% % if applicable
% \end{scope}
% \end{circuitikz}
% }
% \caption{Simplified Block Diagram}
%\end{figure}
\begin{figure}[hbt!]
\centering
\includegraphics[height=2.5in]{photo1008.jpg}
\caption{VHDCI Carrier card}
\includegraphics[height=2.5in, angle=90]{fp1008.pdf}
\caption{VHDCI Carrier front panel}
\end{figure}
% For wide tables, a single column layout is better. It can be switched
% page-by-page.
\onecolumn
\sourcesection{1008 VHDCI Carrier}{https://github.com/sinara-hw/VHDCI_Carrier}
\section{Electrical Specifications}
\begin{table}[h]
\centering
\begin{threeparttable}
\caption{Electrical Specifications}
\begin{tabularx}{0.65\textwidth}{l | c | c | X}
\thickhline
\textbf{Parameter} & \textbf{Max. Value} & \textbf{Unit} & \textbf{Conditions} \\
\thickhline
\end{tabularx}
\end{threeparttable}
\end{table}
Power supply is required when driving EEM cards. 12V should be supplied through barrel jacks (2.50 mm ID, 5.50 mm OD) either in front panel or at back of card.
\ordersection{1008 VHDCI Carrier}
\finalfootnote
\end{document}

View File

@ -1,97 +0,0 @@
\input{preamble.tex}
\graphicspath{{images/1106}, {images}}
\title{1106 EEM AC Power Module}
\author{M-Labs Limited}
\date{January 2025}
\revision{Revision 1}
\companylogo{\includegraphics[height=0.73in]{artiq_sinara.pdf}}
\begin{document}
\maketitle
\section{Features}
\begin{itemize}
\item{Front panel IEC inlet}
\item{80-264V input range}
\item{Five 4-pin Molex MiniFit outputs}
\item{EMC filter}
\end{itemize}
\section{Applications}
\begin{itemize}
\item{Power supply for ARTIQ/Sinara systems}
\item{Provides 400W at 25CFM cooling, 200W with free air convection}
\end{itemize}
\section{General Description}
The 1106 EEM AC Power Module is a 8hp EEM form factor module, part of the ARTIQ/Sinara family. It serves as an in-crate power supply to other Sinara cards such as 1124 Carrier Kasli 2.0 and 1125 Carrier Kasli-SoC.
The AC Power Module features universal IEC input in the front panel and five 4-pin Molex output, directly compatible with Kasli Carriers, at the very rear side of the module. The mains circuit is protected by a steel cover.
% Switch to next column
\vfill\break
%\begin{figure}[h]
% \centering
% \scalebox{1.15}{
% \begin{circuitikz}[european, every label/.append style={align=center}]
% \begin{scope}[]
% % if applicable
% \end{scope}
% \end{circuitikz}
% }
% \caption{Simplified Block Diagram}
%\end{figure}
\begin{figure}[hbt!]
\centering
\includegraphics[height=2.5in]{photo1106.jpg}
\caption{EEM AC Power Module with handle}
\includegraphics[height=2.5in, angle=90]{fp1106.pdf}
\caption{EEM AC Power Module front panel}
\end{figure}
% For wide tables, a single column layout is better. It can be switched
% page-by-page.
\onecolumn
\sourcesection{1106 EEM AC Power Module}{https://github.com/sinara-hw/EEM_PWR_MOD_AC}
\section{Electrical Specifications}
Specifications of parameters are based on the datasheet of the EPP-400-12 power supply\footnote{\url{https://www.meanwell.com/upload/pdf/EPP-400/EPP-400-SPEC.PDF}}.
\begin{table}[h]
\centering
\begin{threeparttable}
\caption{Electrical Specifications}
\begin{tabularx}{0.75\textwidth}{l | c c c | c | X}
\thickhline
\textbf{Parameter} & \textbf{Min} & \textbf{Typ.} & \textbf{Max} & \textbf{Unit} & \textbf{Conditions} \\
\hline
Output voltage & & 12 & & V & \\ \hline
\multirow{2}{*}{Rated current} & & 33.3 & & \multirow{2}{*}{A} & 25CFM forced cooling \\ \cline{2-4}
& & 20.8 & & & Convection \\ \hline
\multirow{2}{*}{Rated power} & & 399.6 & & \multirow{2}{*}{W} & 25CFM forced cooling \\ \cline{2-4}
& & 249.6 & & & Convection \\ \hline
Input voltage & 80 & & 264 & VAC & \\ \hline
Input frequency range & 47 & & 63 & Hz & \\ \hline
\thickhline
\end{tabularx}
\end{threeparttable}
\end{table}
\section{Indicator LEDs}
The 1106 EEM AC Power Module features several indicator LEDs. Four serve as current indicators signaling 25\%, 50\%, 75\% and 100\% load. \texttt{12V} LED signals power on. Additional \texttt{OVERTEMP} LED signals overtemp or overload.
\ordersection{1106 EEM AC Power Module}
\finalfootnote
\end{document}