Compare commits
1 Commits
Author | SHA1 | Date | |
---|---|---|---|
2428dadf00 |
88
1008.tex
Normal file
88
1008.tex
Normal file
@ -0,0 +1,88 @@
|
|||||||
|
\input{preamble.tex}
|
||||||
|
\graphicspath{{images/1008}{images}}
|
||||||
|
|
||||||
|
\title{1008 VHDCI Carrier}
|
||||||
|
\author{M-Labs Limited}
|
||||||
|
\date{January 2025}
|
||||||
|
\revision{Revision 1}
|
||||||
|
\companylogo{\includegraphics[height=0.73in]{artiq_sinara.pdf}}
|
||||||
|
|
||||||
|
\begin{document}
|
||||||
|
\maketitle
|
||||||
|
|
||||||
|
\section{Features}
|
||||||
|
|
||||||
|
\begin{itemize}
|
||||||
|
\item{8 channels}
|
||||||
|
\item{8 internal EEM connectors}
|
||||||
|
\item{2 external VHDCI connectors}
|
||||||
|
\end{itemize}
|
||||||
|
|
||||||
|
\section{Applications}
|
||||||
|
|
||||||
|
\begin{itemize}
|
||||||
|
\item{Break out VHDCI to extension boards}
|
||||||
|
\item{Carry signals over VHDCI between crates}
|
||||||
|
\item{Low-cost alternative to DRTIO}
|
||||||
|
\item{Adapter for certain KC705 ARTIQ systems}
|
||||||
|
\end{itemize}
|
||||||
|
|
||||||
|
\section{General Description}
|
||||||
|
|
||||||
|
The 1008 VHDCI Carrier is a 4hp EEM module, part of the ARTIQ/Sinara family. It is a passive adapter card which converts VHDCI connections to or from EEM connections.
|
||||||
|
|
||||||
|
The 1008 VHDCI Carrier is bidirectional; it can be driven by a core device carrier board, or can drive other cards.
|
||||||
|
|
||||||
|
A pair of VHDCI Carrier cards can be paired with VHDCI SCSI-3 cables to carry EEM signals over short distances between crates. Depending on the application, this can serve as a simple, low-cost, low-latency alternative to multiple core devices and ARTIQ DRTIO.
|
||||||
|
|
||||||
|
% Switch to next column
|
||||||
|
\vfill\break
|
||||||
|
|
||||||
|
%\begin{figure}[h]
|
||||||
|
% \centering
|
||||||
|
% \scalebox{1.15}{
|
||||||
|
% \begin{circuitikz}[european, every label/.append style={align=center}]
|
||||||
|
% \begin{scope}[]
|
||||||
|
% % if applicable
|
||||||
|
% \end{scope}
|
||||||
|
% \end{circuitikz}
|
||||||
|
% }
|
||||||
|
|
||||||
|
% \caption{Simplified Block Diagram}
|
||||||
|
%\end{figure}
|
||||||
|
|
||||||
|
\begin{figure}[hbt!]
|
||||||
|
\centering
|
||||||
|
\includegraphics[height=2.5in]{photo1008.jpg}
|
||||||
|
\caption{VHDCI Carrier card}
|
||||||
|
\includegraphics[height=2.5in, angle=90]{fp1008.pdf}
|
||||||
|
\caption{VHDCI Carrier front panel}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
|
% For wide tables, a single column layout is better. It can be switched
|
||||||
|
% page-by-page.
|
||||||
|
\onecolumn
|
||||||
|
|
||||||
|
\sourcesection{1008 VHDCI Carrier}{https://github.com/sinara-hw/VHDCI_Carrier}
|
||||||
|
|
||||||
|
\section{Electrical Specifications}
|
||||||
|
|
||||||
|
\begin{table}[h]
|
||||||
|
\centering
|
||||||
|
\begin{threeparttable}
|
||||||
|
\caption{Electrical Specifications}
|
||||||
|
\begin{tabularx}{0.65\textwidth}{l | c | c | X}
|
||||||
|
\thickhline
|
||||||
|
\textbf{Parameter} & \textbf{Max. Value} & \textbf{Unit} & \textbf{Conditions} \\
|
||||||
|
\thickhline
|
||||||
|
\end{tabularx}
|
||||||
|
\end{threeparttable}
|
||||||
|
\end{table}
|
||||||
|
|
||||||
|
Power supply is required when driving EEM cards. 12V should be supplied through barrel jacks (2.50 mm ID, 5.50 mm OD) either in front panel or at back of card.
|
||||||
|
|
||||||
|
\ordersection{1008 VHDCI Carrier}
|
||||||
|
|
||||||
|
\finalfootnote
|
||||||
|
|
||||||
|
\end{document}
|
97
1106.tex
97
1106.tex
@ -1,97 +0,0 @@
|
|||||||
\input{preamble.tex}
|
|
||||||
\graphicspath{{images/1106}, {images}}
|
|
||||||
|
|
||||||
\title{1106 EEM AC Power Module}
|
|
||||||
\author{M-Labs Limited}
|
|
||||||
\date{January 2025}
|
|
||||||
\revision{Revision 1}
|
|
||||||
\companylogo{\includegraphics[height=0.73in]{artiq_sinara.pdf}}
|
|
||||||
|
|
||||||
\begin{document}
|
|
||||||
\maketitle
|
|
||||||
|
|
||||||
\section{Features}
|
|
||||||
|
|
||||||
\begin{itemize}
|
|
||||||
\item{Front panel IEC inlet}
|
|
||||||
\item{80-264V input range}
|
|
||||||
\item{Five 4-pin Molex MiniFit outputs}
|
|
||||||
\item{EMC filter}
|
|
||||||
\end{itemize}
|
|
||||||
|
|
||||||
\section{Applications}
|
|
||||||
|
|
||||||
\begin{itemize}
|
|
||||||
\item{Power supply for ARTIQ/Sinara systems}
|
|
||||||
\item{Provides 400W at 25CFM cooling, 200W with free air convection}
|
|
||||||
\end{itemize}
|
|
||||||
|
|
||||||
\section{General Description}
|
|
||||||
|
|
||||||
The 1106 EEM AC Power Module is a 8hp EEM form factor module, part of the ARTIQ/Sinara family. It serves as an in-crate power supply to other Sinara cards such as 1124 Carrier Kasli 2.0 and 1125 Carrier Kasli-SoC.
|
|
||||||
|
|
||||||
The AC Power Module features universal IEC input in the front panel and five 4-pin Molex output, directly compatible with Kasli Carriers, at the very rear side of the module. The mains circuit is protected by a steel cover.
|
|
||||||
|
|
||||||
% Switch to next column
|
|
||||||
\vfill\break
|
|
||||||
|
|
||||||
%\begin{figure}[h]
|
|
||||||
% \centering
|
|
||||||
% \scalebox{1.15}{
|
|
||||||
% \begin{circuitikz}[european, every label/.append style={align=center}]
|
|
||||||
% \begin{scope}[]
|
|
||||||
% % if applicable
|
|
||||||
% \end{scope}
|
|
||||||
% \end{circuitikz}
|
|
||||||
% }
|
|
||||||
|
|
||||||
% \caption{Simplified Block Diagram}
|
|
||||||
%\end{figure}
|
|
||||||
|
|
||||||
\begin{figure}[hbt!]
|
|
||||||
\centering
|
|
||||||
\includegraphics[height=2.5in]{photo1106.jpg}
|
|
||||||
\caption{EEM AC Power Module with handle}
|
|
||||||
\includegraphics[height=2.5in, angle=90]{fp1106.pdf}
|
|
||||||
\caption{EEM AC Power Module front panel}
|
|
||||||
\end{figure}
|
|
||||||
|
|
||||||
% For wide tables, a single column layout is better. It can be switched
|
|
||||||
% page-by-page.
|
|
||||||
\onecolumn
|
|
||||||
|
|
||||||
\sourcesection{1106 EEM AC Power Module}{https://github.com/sinara-hw/EEM_PWR_MOD_AC}
|
|
||||||
|
|
||||||
\section{Electrical Specifications}
|
|
||||||
|
|
||||||
Specifications of parameters are based on the datasheet of the EPP-400-12 power supply\footnote{\url{https://www.meanwell.com/upload/pdf/EPP-400/EPP-400-SPEC.PDF}}.
|
|
||||||
|
|
||||||
\begin{table}[h]
|
|
||||||
\centering
|
|
||||||
\begin{threeparttable}
|
|
||||||
\caption{Electrical Specifications}
|
|
||||||
\begin{tabularx}{0.75\textwidth}{l | c c c | c | X}
|
|
||||||
\thickhline
|
|
||||||
\textbf{Parameter} & \textbf{Min} & \textbf{Typ.} & \textbf{Max} & \textbf{Unit} & \textbf{Conditions} \\
|
|
||||||
\hline
|
|
||||||
Output voltage & & 12 & & V & \\ \hline
|
|
||||||
\multirow{2}{*}{Rated current} & & 33.3 & & \multirow{2}{*}{A} & 25CFM forced cooling \\ \cline{2-4}
|
|
||||||
& & 20.8 & & & Convection \\ \hline
|
|
||||||
\multirow{2}{*}{Rated power} & & 399.6 & & \multirow{2}{*}{W} & 25CFM forced cooling \\ \cline{2-4}
|
|
||||||
& & 249.6 & & & Convection \\ \hline
|
|
||||||
Input voltage & 80 & & 264 & VAC & \\ \hline
|
|
||||||
Input frequency range & 47 & & 63 & Hz & \\ \hline
|
|
||||||
\thickhline
|
|
||||||
\end{tabularx}
|
|
||||||
\end{threeparttable}
|
|
||||||
\end{table}
|
|
||||||
|
|
||||||
\section{Indicator LEDs}
|
|
||||||
|
|
||||||
The 1106 EEM AC Power Module features several indicator LEDs. Four serve as current indicators signaling 25\%, 50\%, 75\% and 100\% load. \texttt{12V} LED signals power on. Additional \texttt{OVERTEMP} LED signals overtemp or overload.
|
|
||||||
|
|
||||||
\ordersection{1106 EEM AC Power Module}
|
|
||||||
|
|
||||||
\finalfootnote
|
|
||||||
|
|
||||||
\end{document}
|
|
BIN
images/1008/fp1008.pdf
Normal file
BIN
images/1008/fp1008.pdf
Normal file
Binary file not shown.
BIN
images/1008/photo1008.jpg
Normal file
BIN
images/1008/photo1008.jpg
Normal file
Binary file not shown.
After Width: | Height: | Size: 282 KiB |
Binary file not shown.
Binary file not shown.
Before Width: | Height: | Size: 260 KiB |
Loading…
Reference in New Issue