diff --git a/4410.tex b/4410.tex index 897857a..5729b3d 100644 --- a/4410.tex +++ b/4410.tex @@ -4,7 +4,6 @@ \usepackage{minted} \usepackage{tcolorbox} \usepackage{etoolbox} -\usepackage{makecell} \BeforeBeginEnvironment{minted}{\begin{tcolorbox}[colback=white]}% \AfterEndEnvironment{minted}{\end{tcolorbox}}% @@ -47,7 +46,7 @@ \begin{itemize} \item{Agile local oscillator (LO) frequency synthesis.} \item{Programmable clock generators.} -\item{FM chirp source for radar and scanning systems.} +\item{Fast frequency hopping.} \end{itemize} \section{General Description} @@ -307,6 +306,59 @@ Urukul comes with either AD9910 or AD9912 chips. \onecolumn \section{Electrical Specifications} +\begin{table}[h] +\begin{threeparttable} +\caption{Recommended Operating Conditions} +\begin{tabularx}{\textwidth}{l | c | c c c | c | X} + \thickhline + \textbf{Parameter} & \textbf{Symbol} & \textbf{Min.} & \textbf{Typ.} & \textbf{Max.} & + \textbf{Unit} & \textbf{Conditions} \\ + \hline + Clock input & & & & & &\\ + \hspace{3mm} Input frequency & & 10 & & 1000 & MHz & PLL disabled \\ + & & 3.2 & & 60 & MHz & AD9910, PLL enabled, no clock division \\ + & & 12.8 & & 240 & MHz & AD9910, PLL enabled, 4x clock division \\ + & & 11 & & 200 & MHz & AD9912, PLL enabled, no clock division \\ + & & 44 & & 800 & MHz & AD9912, PLL enabled, 4x clock division \\ + \hspace{3mm} Nominal input power & & & 10 & & dBm & \\ + \hline + Air flow & & 50 & & & cm/s & \\ + \thickhline +\end{tabularx} +\end{threeparttable} +\end{table} + +\begin{table}[h] +\begin{threeparttable} +\caption{RF Output Specifications} +\begin{tabularx}{\textwidth}{l | c | c c c | c | X} + \thickhline + \textbf{Parameter} & \textbf{Symbol} & \textbf{Min.} & \textbf{Typ.} & \textbf{Max.} & + \textbf{Unit} & \textbf{Conditions} \\ + \hline + Nominal power & & & & 10 & dBm & 13 dBm P1dB\\ + \hline + Frequency & & 1 & & 400 & MHz & \\ + \hline + Attenuation & & -31.5 & & 0 & dB & \\ + \hline + Resolution & & & & & & \\ + \hspace{3mm} Frequency & & & 0.25 & & Hz & AD9910 \\ + & & & 8 & & $\mu$Hz & AD9912 \\ + \hspace{3mm} Phase offset & & & 16 & & bits & AD9910 \\ + & & & 14 & & bits & AD9912 \\ + \hspace{3mm} Digital amplitude & & & 14 & & bits & AD9910 \\ + \hspace{3mm} DAC full scale current & & & 8 & & bits & AD9910 \\ + & & & 10 & & bits & AD9912 \\ + \hspace{3mm} Temporal (I/O Update) & & & 4 & & ns & \\ + \hspace{3mm} Attenuation & & & 0.5 & & dB & \\ + \thickhline +\end{tabularx} +\end{threeparttable} +\end{table} + +All performance data are produced using 1 GHz PLL unless otherwise noted. + \begin{table}[h] \begin{threeparttable} \caption{Electrical Characteristics} @@ -315,13 +367,7 @@ Urukul comes with either AD9910 or AD9912 chips. \textbf{Parameter} & \textbf{Symbol} & \textbf{Min.} & \textbf{Typ.} & \textbf{Max.} & \textbf{Unit} & \textbf{Conditions} \\ \hline - Output power & $P$ & -19 & & 12.5 & dBm & \\ - \hline - Output frequency & $f$ & 1 & & 400 & MHz & \\ - \hline - Digital attenuator & & & & & &\\ - \hspace{3mm} Range & & -31.5 & & 0 & dB & \\ - \hspace{3mm} Glitch duration & & & 100 & & ns & \\ + Attenuator glitch duration & & & 100 & & ns & \\ \hline RF switch & & & & & &\\ \hspace{3mm} Rise to 90\% & $t_{on}$ & & 100 & & ns & \\ @@ -333,7 +379,7 @@ Urukul comes with either AD9910 or AD9912 chips. \hline Cross-channel-intermodulation & & & -90 & & dB & \\ \hline - Phase noise & $\mathcal{L}(f)$ & & & & & \makecell[l]{100 MHz ref in, \\1 GHz DDS PLL, \\81 MHz output\\}\\ + Phase noise & $\mathcal{L}(f)$ & & & & & 100 MHz ref in, 81 MHz output\\ & & & -85 & & dBc/Hz & 0.1 Hz \\ & & & -95 & & dBc/Hz & 1 Hz \\ & & & -107 & & dBc/Hz & 10 Hz \\ @@ -344,11 +390,15 @@ Urukul comes with either AD9910 or AD9912 chips. & & & -128 & & dBc/Hz & 1 MHz \\ & & & -149 & & dBc/Hz & 10 MHz \\ \hline + Power consumption (AD9910) & & & 7 & & W & 4x 400 MHz, 10.5 dBm, 52\degree C\\ + Power consumption (AD9912) & & & 6.5 & & W & 4x 400 MHz, 10.5 dBm, 52\degree C\\ \thickhline \end{tabularx} \end{threeparttable} \end{table} +\newpage + \section{Example ARTIQ code} The sections below demonstrate simple usage scenarios of the 4410 Urukul card with the ARTIQ control system. They do not exhaustively demonstrate all the features of the ARTIQ system.