fastino: add zero voltage output failure mode
This commit is contained in:
parent
f4fd9ac0a1
commit
4b03c538a1
|
@ -56,3 +56,19 @@ Press ENTER when done.
|
||||||
|
|
||||||
This may happen when power-cycle is too short. Power down the crate, wait at least 30 seconds, and power up again.
|
This may happen when power-cycle is too short. Power down the crate, wait at least 30 seconds, and power up again.
|
||||||
[Issue](https://github.com/sinara-hw/Zotino/issues/37).
|
[Issue](https://github.com/sinara-hw/Zotino/issues/37).
|
||||||
|
|
||||||
|
### Zero voltage output on Fastino
|
||||||
|
|
||||||
|
Some Fastino may not output any voltage during testing, usually that means it has no gateware.
|
||||||
|
|
||||||
|
Another common symptom of no gateware is that no LEDs are lit up. Whereas if the gateware has been flashed, the PG and FD LEDs will be lit green.
|
||||||
|
|
||||||
|
You can flash the gateware with a standalone Kasli/Kasli-SoC:
|
||||||
|
|
||||||
|
1. Download the latest `fastino.bin` release from [quartiq/fastino](https://github.com/quartiq/fastino/releases)
|
||||||
|
2. Run `git clone https://github.com/quartiq/kasli-i2c.git` and place `fastino.bin` in the kasli-i2c directory
|
||||||
|
2. Connect the Fastino's EEM0 to any available Kasli/Kasli-SoC EEM port (**do not hot-plug**)
|
||||||
|
3. Power on the standalone Kasli/Kasli-SoC
|
||||||
|
4. Run `nix-shell -p python311Packages.pyftdi`
|
||||||
|
5. Run `cd kasli-i2c; python flash_fastino.py 0 EEM<number> write fastino.bin` where `<number>` is the EEM port number on the Kasli/Kasli-SoC side
|
||||||
|
6. If PG and FD LEDs are lit green, the Fastino is ready.
|
||||||
|
|
Loading…