Overheating issues for DRTIO
Signed-off-by: Egor Savkin <es@m-labs.hk>
This commit is contained in:
parent
68e2015f3a
commit
32567574fc
@ -45,3 +45,9 @@ During the connection, the clock signal is being distributed, effectively making
|
||||
* Wrong setups - master to master, standalone to standalone. Messing up with SFP ports generally makes it unusable,
|
||||
but the connection should be established in most cases.
|
||||
* The fiber adapters are not symmetrical - if one end has 1270/1330 label, another one should be 1330/1270.
|
||||
|
||||
|
||||
### Master-satellite interrupted/unstable connection
|
||||
|
||||
This often happens due to overheating issues. Check if the Kasli/SoC fans are working properly and
|
||||
try installing rack fans to increase the air flow.
|
Loading…
Reference in New Issue
Block a user