Overheating issues for DRTIO

Signed-off-by: Egor Savkin <es@m-labs.hk>
This commit is contained in:
Egor Savkin 2024-04-30 10:35:21 +08:00
parent 68e2015f3a
commit 32567574fc
1 changed files with 6 additions and 0 deletions

View File

@ -45,3 +45,9 @@ During the connection, the clock signal is being distributed, effectively making
* Wrong setups - master to master, standalone to standalone. Messing up with SFP ports generally makes it unusable,
but the connection should be established in most cases.
* The fiber adapters are not symmetrical - if one end has 1270/1330 label, another one should be 1330/1270.
### Master-satellite interrupted/unstable connection
This often happens due to overheating issues. Check if the Kasli/SoC fans are working properly and
try installing rack fans to increase the air flow.