forked from sinara-hw/assembly
Add mismatch problem to the urukul and add known issue to the kasli-soc
Signed-off-by: Egor Savkin <es@m-labs.hk>
This commit is contained in:
parent
598e825432
commit
af2d962821
|
@ -61,6 +61,11 @@ artiq_coremgmt config write -f boot result/boot.bin
|
||||||
artiq_sinara_tester
|
artiq_sinara_tester
|
||||||
```
|
```
|
||||||
|
|
||||||
|
### Known issues
|
||||||
|
|
||||||
|
* [artiq-zynq#197](https://git.m-labs.hk/M-Labs/artiq-zynq/issues/197) - some cards (Sampler, Mirny, Zotino and others)
|
||||||
|
do not work properly with some EEM ports. You might need to reconnect the card to the other ports until it gets working.
|
||||||
|
|
||||||
## Master-satellite setups
|
## Master-satellite setups
|
||||||
|
|
||||||
1. Change `base` in JSON to the respective `master` or `satellite`, add `"enable_sata_drtio": true` if needed to the master,
|
1. Change `base` in JSON to the respective `master` or `satellite`, add `"enable_sata_drtio": true` if needed to the master,
|
||||||
|
|
|
@ -9,7 +9,7 @@
|
||||||
{
|
{
|
||||||
"type": "urukul",
|
"type": "urukul",
|
||||||
"dds": "<variant>", // ad9910/ad9912
|
"dds": "<variant>", // ad9910/ad9912
|
||||||
"ports": [<port num>, <port num>],
|
"ports": [<port num>, <port num>], // second port is optional
|
||||||
"clk_sel": <clock num>,
|
"clk_sel": <clock num>,
|
||||||
"refclk": <freq>, // for external clock signal
|
"refclk": <freq>, // for external clock signal
|
||||||
"pll_en": <0 or 1, default 1> // PLL bypass, to allow higher external clocker frequencies (1e9 for example)
|
"pll_en": <0 or 1, default 1> // PLL bypass, to allow higher external clocker frequencies (1e9 for example)
|
||||||
|
@ -112,4 +112,12 @@ ValueError: PLL lock timeout
|
||||||
|
|
||||||
This can happen due to lack/bad clock source connection. Check that clock source is connected respective to the customer needs,
|
This can happen due to lack/bad clock source connection. Check that clock source is connected respective to the customer needs,
|
||||||
and if it is connected to the [Clocker](clocker.md), check that clocker receives clock signal properly and `EXT`/`INT` pin
|
and if it is connected to the [Clocker](clocker.md), check that clocker receives clock signal properly and `EXT`/`INT` pin
|
||||||
matches real clocker source.
|
matches real clocker source.
|
||||||
|
|
||||||
|
### Urukul AD9910 AUX_DAC mismatch
|
||||||
|
|
||||||
|
```pycon
|
||||||
|
ValueError: Urukul AD9910 AUX_DAC mismatch
|
||||||
|
```
|
||||||
|
|
||||||
|
Ensure it is the AD9910 and not the AD9912.
|
Loading…