# Python Test Scripts for Controlling Kirdy
|
||||
# Kirdy is written to be controlled via a json object based on miniconf rust crate
|
||||
# Json Field:
|
||||
# "laser_diode_cmd / thermostat_cmd": Check cmd_handler.rs for the list of cmds
|
||||
# "data_f32": Optional f32 Data field depending on cmd
|
||||
# "data_f64": Optional f64 Data field depending on cmd
|
||||
|
||||
import socket
|
||||
import json
|
||||
import time
|
||||
import signal
|
||||
|
||||
# Kirdy IP and Port Number
|
||||
HOST = "192.168.1.132"
|
||||
PORT = 1337
|
||||
|
||||
dfu_cmd = {
|
||||
"device_cmd": "Dfu",
|
||||
}
|
||||
|
||||
ld_cmd = {
|
||||
"laser_diode_cmd": "SetI",
|
||||
"data_f32": 0.0,
|
||||
}
|
||||
|
||||
tec_clear_alarm = {
|
||||
"thermostat_cmd": "ClearAlarm",
|
||||
}
|
||||
|
||||
tec_power_down = {
|
||||
"thermostat_cmd": "PowerDown",
|
||||
}
|
||||
|
||||
tec_set_sh_t0_cmd = {
|
||||
"thermostat_cmd": "SetShT0",
|
||||
"data_f32": 25.0,
|
||||
}
|
||||
|
||||
tec_set_sh_r0_cmd = {
|
||||
"thermostat_cmd": "SetShR0",
|
||||
"data_f32": 10.0 * 1000,
|
||||
}
|
||||
|
||||
tec_set_sh_beta_cmd = {
|
||||
"thermostat_cmd": "SetShBeta",
|
||||
"data_f32": 3900.0,
|
||||
}
|
||||
|
||||
tec_set_temperature_setpoint_cmd = {
|
||||
"thermostat_cmd": "SetTemperatureSetpoint",
|
||||
"data_f32": 30.0,
|
||||
}
|
||||
|
||||
tec_set_pid_kp_cmd = {
|
||||
"thermostat_cmd": "SetPidKp",
|
||||
"data_f32": 0.14398316474562461
|
||||
}
|
||||
|
||||
tec_set_pid_ki_cmd = {
|
||||
"thermostat_cmd": "SetPidKi",
|
||||
"data_f32": 0.004117762308816449
|
||||
}
|
||||
|
||||
tec_set_pid_kd_cmd = {
|
||||
"thermostat_cmd": "SetPidKd",
|
||||
"data_f32": 0.36324599631515664
|
||||
}
|
||||
|
||||
tec_set_pid_out_min_cmd = {
|
||||
"thermostat_cmd": "SetPidOutMin",
|
||||
"data_f32": -1.0,
|
||||
}
|
||||
|
||||
tec_set_pid_out_max_cmd = {
|
||||
"thermostat_cmd": "SetPidOutMax",
|
||||
"data_f32": 1.0,
|
||||
}
|
||||
|
||||
tec_power_up = {
|
||||
"thermostat_cmd": "PowerUp",
|
||||
}
|
||||
|
||||
tec_pid_engage = {
|
||||
"thermostat_cmd": "SetPidEngage",
|
||||
}
|
||||
|
||||
kirdy_get_status_report = {
|
||||
"device_cmd": "GetStatusReport",
|
||||
}
|
||||
|
||||
kirdy_report_mode_cmd = {
|
||||
"device_cmd": "SetActiveReportMode",
|
||||
"data_bool": True,
|
||||
}
|
||||
|
||||
temp_adc_config = {
|
||||
"thermostat_cmd": "ConfigTempAdcFilter",
|
||||
"temp_adc_filter": {
|
||||
"filter_type": "Sinc5Sinc1With50hz60HzRejection",
|
||||
"sinc5sinc1postfilter": "F16SPS"
|
||||
}
|
||||
}
|
||||
|
||||
def send_cmd(input, socket):
|
||||
socket.send(bytes(json.dumps(input), "UTF-8"))
|
||||
# Give some time for Kirdy to process the cmd
|
||||
time.sleep(0.5)
|
||||
|
||||
def poll_status_report(socket):
|
||||
while True:
|
||||
data = socket.recv(1024).decode('utf8')
|
||||
try:
|
||||
json_data = json.loads(data)
|
||||
break
|
||||
except json.decoder.JSONDecodeError:
|
||||
pass
|
||||
return json_data
|
||||
|
||||
s = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
|
||||
|
||||
def signal_handler(sig, frame):
|
||||
ld_cmd["data_f32"] = 0.0
|
||||
send_cmd(ld_cmd, s)
|
||||
send_cmd(tec_power_down, s)
|
||||
s.close()
|
||||
exit()
|
||||
|
||||
signal.signal(signal.SIGINT, signal_handler)
|
||||
|
||||
with socket.socket(socket.AF_INET, socket.SOCK_STREAM) as s:
|
||||
s.connect((HOST, PORT))
|
||||
send_cmd(ld_cmd, s)
|
||||
send_cmd(tec_power_down, s)
|
||||
send_cmd(tec_set_sh_t0_cmd, s)
|
||||
send_cmd(tec_set_sh_r0_cmd, s)
|
||||
send_cmd(tec_set_sh_beta_cmd, s)
|
||||
send_cmd(tec_set_temperature_setpoint_cmd, s)
|
||||
send_cmd(tec_set_pid_kp_cmd, s)
|
||||
send_cmd(tec_set_pid_ki_cmd, s)
|
||||
send_cmd(tec_set_pid_kd_cmd, s)
|
||||
send_cmd(tec_clear_alarm, s)
|
||||
send_cmd(temp_adc_config, s)
|
||||
send_cmd(tec_pid_engage, s)
|
||||
send_cmd(tec_power_up, s)
|
||||
send_cmd(kirdy_report_mode_cmd, s)
|
||||
|
||||
while True:
|
||||
status_report = poll_status_report(s)
|
||||
print(f"Ts: {status_report['ts']} | Temperature: {status_report['tec']['temperature'] - 273.15}")
|
47
pykirdy/asyncio_exmaple.py
Normal file
47
pykirdy/asyncio_exmaple.py
Normal file
@ -0,0 +1,47 @@
|
||||
from driver.kirdy_async import Kirdy
|
||||
import asyncio
|
||||
|
||||
async def main():
|
||||
kirdy = Kirdy()
|
||||
await kirdy.start_session(host='192.168.1.128', port=1337, timeout=0.25)
|
||||
await kirdy.device.set_active_report_mode(False)
|
||||
|
||||
await kirdy.laser.set_power_on(False)
|
||||
await kirdy.laser.clear_alarm()
|
||||
await kirdy.laser.set_i(0)
|
||||
await kirdy.laser.set_i_soft_limit(250)
|
||||
await kirdy.laser.set_power_on(True)
|
||||
|
||||
await kirdy.thermostat.set_power_on(False)
|
||||
await kirdy.thermostat.clear_alarm()
|
||||
|
||||
await kirdy.thermostat.set_sh_r0(10.0*1000)
|
||||
await kirdy.thermostat.set_sh_t0(25)
|
||||
await kirdy.thermostat.set_sh_beta(3900)
|
||||
|
||||
await kirdy.thermostat.set_temperature_setpoint(25)
|
||||
await kirdy.thermostat.set_temp_mon_upper_limit(40)
|
||||
await kirdy.thermostat.set_temp_mon_lower_limit(10)
|
||||
|
||||
await kirdy.thermostat.set_pid_kp(0.15668282198105507)
|
||||
await kirdy.thermostat.set_pid_ki(0.002135962407793784)
|
||||
await kirdy.thermostat.set_pid_kd(0.829254515277143)
|
||||
|
||||
await kirdy.thermostat.set_pid_output_max(1.0)
|
||||
await kirdy.thermostat.set_pid_output_min(-1.0)
|
||||
|
||||
await kirdy.thermostat.config_temp_adc_filter("Sinc5Sinc1With50hz60HzRejection", "F16SPS")
|
||||
await kirdy.thermostat.set_power_on(True)
|
||||
await kirdy.thermostat.set_pid_control_mode()
|
||||
|
||||
await kirdy.laser.set_default_pwr_on(False)
|
||||
await kirdy.thermostat.set_default_pwr_on(True)
|
||||
await kirdy.device.save_current_settings_to_flash()
|
||||
|
||||
async for data in kirdy.report_mode():
|
||||
print(data)
|
||||
|
||||
await kirdy.end_session()
|
||||
|
||||
if __name__ == "__main__":
|
||||
asyncio.run(main())
|
699
pykirdy/driver/kirdy_async.py
Normal file
699
pykirdy/driver/kirdy_async.py
Normal file
@ -0,0 +1,699 @@
|
||||
import socket
|
||||
import asyncio
|
||||
import json
|
||||
|
||||
# Data Type Enums
|
||||
IP_SETTINGS = "ip_settings"
|
||||
TEMP_ADC_FILTER = "temp_adc_filter"
|
||||
DATA_F32 = "data_f32"
|
||||
DATA_BOOL = "data_bool"
|
||||
|
||||
TARGET_DEVICE = "device_cmd"
|
||||
TARGET_LD = "laser_diode_cmd"
|
||||
TARGET_THERMOSTAT = "thermostat_cmd"
|
||||
|
||||
class CmdDoesNotExist(Exception):
|
||||
pass
|
||||
|
||||
class InvalidDataType(Exception):
|
||||
pass
|
||||
|
||||
class NoAckRecv(Exception):
|
||||
pass
|
||||
|
||||
Filter_Config = {
|
||||
"Sinc5Sinc1With50hz60HzRejection": [
|
||||
"sinc5sinc1postfilter",
|
||||
[
|
||||
"F27SPS",
|
||||
"F21SPS",
|
||||
"F20SPS",
|
||||
"F16SPS",
|
||||
]
|
||||
],
|
||||
"Sinc5Sinc1": [
|
||||
"sinc5sinc1odr",
|
||||
[
|
||||
"F31250_0SPS",
|
||||
"F15625_0SPS",
|
||||
"F10417_0SPS",
|
||||
"F5208_0SPS" ,
|
||||
"F2597_0SPS" ,
|
||||
"F1007_0SPS" ,
|
||||
"F503_8SPS" ,
|
||||
"F381_0SPS" ,
|
||||
"F200_3SPS" ,
|
||||
"F100_2SPS" ,
|
||||
"F59_52SPS" ,
|
||||
"F49_68SPS" ,
|
||||
"F20_01SPS" ,
|
||||
"F16_63SPS" ,
|
||||
"F10_0SPS" ,
|
||||
"F5_0SPS" ,
|
||||
"F2_5SPS" ,
|
||||
"F1_25SPS" ,
|
||||
]
|
||||
],
|
||||
"Sinc3": [
|
||||
"sinc3odr",
|
||||
[
|
||||
"F31250_0SPS",
|
||||
"F15625_0SPS",
|
||||
"F10417_0SPS",
|
||||
"F5208_0SPS" ,
|
||||
"F2597_0SPS" ,
|
||||
"F1007_0SPS" ,
|
||||
"F503_8SPS" ,
|
||||
"F381_0SPS" ,
|
||||
"F200_3SPS" ,
|
||||
"F100_2SPS" ,
|
||||
"F59_52SPS" ,
|
||||
"F49_68SPS" ,
|
||||
"F20_01SPS" ,
|
||||
"F16_63SPS" ,
|
||||
"F10_0SPS" ,
|
||||
"F5_0SPS" ,
|
||||
"F2_5SPS" ,
|
||||
"F1_25SPS" ,
|
||||
]
|
||||
],
|
||||
"Sinc3WithFineODR": [
|
||||
"sinc3fineodr",
|
||||
DATA_F32
|
||||
],
|
||||
}
|
||||
|
||||
class Device:
|
||||
def __init__(self, send_cmd_handler, send_raw_cmd_handler, read_response):
|
||||
self._send_cmd = send_cmd_handler
|
||||
self._send_raw_cmd = send_raw_cmd_handler
|
||||
self._read_response = read_response
|
||||
|
||||
async def set_ip_settings(self, addr=[192, 168, 1, 132], port=1337, prefix_len=24, gateway=[192, 168, 1, 1]):
|
||||
"""
|
||||
After calling this fn, the user needs to issue the SaveFlashSettings cmd and then issue a
|
||||
Hard Reset/Power Cycle Kirdy for the new network settings to be effective.
|
||||
"""
|
||||
if not(isinstance(addr, list) and isinstance(gateway, list)):
|
||||
raise InvalidDataType
|
||||
|
||||
if not(len(addr) == 4 and len(gateway) == 4):
|
||||
raise InvalidDataType
|
||||
|
||||
if not(isinstance(port, int) and isinstance(prefix_len, int)):
|
||||
raise InvalidDataType
|
||||
|
||||
return await self._send_raw_cmd(
|
||||
{
|
||||
"device_cmd": "SetIPSettings",
|
||||
"ip_settings": {
|
||||
"addr": addr,
|
||||
"port": port,
|
||||
"prefix_len": prefix_len,
|
||||
"gateway": gateway,
|
||||
}
|
||||
}
|
||||
)
|
||||
|
||||
async def set_active_report_mode(self, on):
|
||||
"""
|
||||
Set active report to be on. If it is on, Kirdy will send status report
|
||||
to ALL client socket connections according to the temperature polling rate set.
|
||||
"""
|
||||
return await self._send_cmd(TARGET_DEVICE, "SetActiveReportMode", on)
|
||||
|
||||
async def get_status_report(self):
|
||||
"""
|
||||
{
|
||||
'laser': {
|
||||
default_pwr_on': False, # Power On Laser Diode at Startup
|
||||
ld_drive_current': { # Laser Diode Output Current(A)
|
||||
'value': 0.0, # Value Set
|
||||
'max': 0.3 # Max Value Settable
|
||||
,
|
||||
ld_drive_current_limit': { # Laser Diode Software Current Limit(A)
|
||||
'value': 0.3, # Value Set
|
||||
'max': 0.3 # Max Value Settable
|
||||
,
|
||||
pd_responsitivity': { # Laser Diode Software Current Limit(A)
|
||||
'responsitivity': None, # Value Set
|
||||
'i_dark': 0.0 # Max Value Settable
|
||||
,
|
||||
ld_pwr_limit': 0.0 # Laser Diode Power Limit(W)
|
||||
},
|
||||
'thermostat': {
|
||||
'default_pwr_on': True, # Power on Thermostat at Startup
|
||||
'pid_engaged': True, # True: PID Control Mode | False Constant Current Mode
|
||||
'temperature_setpoint': 298.15, # Temperature Setpoint (K)
|
||||
'tec_settings': {
|
||||
'i_set': { # Current TEC Current Set by PID Controller/User
|
||||
'value': 0.04330516, # Value Set
|
||||
'max': 1.0 # Max Value Settable
|
||||
},
|
||||
'max_v': { # Max Voltage Across Tec Terminals
|
||||
'value': 4.990857, # Value Set
|
||||
'max': 5.0 # Max Value Settable
|
||||
},
|
||||
'max_i_pos': { # Max Cooling Current Across Tec Terminals
|
||||
'value': 0.99628574, # Value Set
|
||||
'max': 1.0 # Max Value Settable
|
||||
},
|
||||
'max_i_neg': { # Max Heating Current Across Tec Terminals
|
||||
'value': 0.99628574, # Value Set
|
||||
'max': 1.0 # Max Value Settable
|
||||
}
|
||||
},
|
||||
'pid_params': { # PID Controller Parameters
|
||||
'kp': 0.15668282, # Proportional Gain
|
||||
'ki': 0.0021359625, # Integral Gain
|
||||
'kd': 0.8292545, # Derivative Gain
|
||||
'output_min': -1.0, # Minimum Current Output (A)
|
||||
'output_max': 1.0 # Maximum Current Output (A)
|
||||
},
|
||||
'temp_adc_settings': { # Temperature ADC Settings (Please read AD7172-2 Documentation)
|
||||
'filter_type': 'Sinc5Sinc1With50hz60HzRejection', # Filter Types
|
||||
'sinc5sinc1odr': None, # (Unused)
|
||||
'sinc3odr': None, # (Unused)
|
||||
'sinc5sinc1postfilter': None, # (Unused)
|
||||
'sinc3fineodr': None, # (Unused)
|
||||
'rate': 16.67 # ADC Sampling Rate (Hz)
|
||||
},
|
||||
'temp_mon_settings': { # Temperature Monitor Settings
|
||||
'upper_limit': 40.0, # Temperature Upper Limit (Degree Celsius)
|
||||
'lower_limit': 10.0 # Temperature Lower Limit (Degree Celsius)
|
||||
},
|
||||
'thermistor_params': { # Thermistor Steinhart-Hart equation parameters
|
||||
't0': 25.0, # t0: Degree Celsius
|
||||
'r0': 10000.0, # r0: Ohm
|
||||
'b': 3900.0 # b: (unitless)
|
||||
}
|
||||
}
|
||||
}
|
||||
"""
|
||||
|
||||
response = await self._send_cmd(TARGET_DEVICE, "GetStatusReport")
|
||||
if response["msg_type"] != "Acknowledge":
|
||||
return response
|
||||
return await self._read_response()
|
||||
|
||||
async def get_settings_summary(self):
|
||||
response = await self._send_cmd(TARGET_DEVICE, "GetSettingsSummary")
|
||||
if response["msg_type"] != "Acknowledge":
|
||||
return response
|
||||
return await self._read_response()
|
||||
|
||||
async def dfu(self):
|
||||
"""
|
||||
Issuing this cmd will HARD RESET the device and
|
||||
put Kirdy into Dfu mode for flashing firmware.
|
||||
"""
|
||||
return await self._send_cmd(TARGET_DEVICE, "Dfu")
|
||||
|
||||
async def save_current_settings_to_flash(self):
|
||||
"""
|
||||
Save the current device configurations into flash.
|
||||
"""
|
||||
return await self._send_cmd(TARGET_DEVICE, "SaveFlashSettings")
|
||||
|
||||
async def load_current_settings_to_flash(self):
|
||||
"""
|
||||
Restore stored settings in flash
|
||||
"""
|
||||
return await self._send_cmd(TARGET_DEVICE, "LoadFlashSettings")
|
||||
|
||||
async def hard_reset(self):
|
||||
"""
|
||||
Hard Reset Kirdy. The socket connection will be closed by Kirdy.
|
||||
Laser diode power and Tec power will be turned off.
|
||||
"""
|
||||
return await self._send_cmd(TARGET_DEVICE, "HardReset")
|
||||
|
||||
class Laser:
|
||||
def __init__(self, send_cmd_handler):
|
||||
self._send_cmd = send_cmd_handler
|
||||
|
||||
async def set_power_on(self, on):
|
||||
"""
|
||||
Power Up or Power Down laser diode. Powering up the Laser Diode resets the pwr_excursion status
|
||||
- on (True/False)
|
||||
"""
|
||||
if on:
|
||||
return await self._send_cmd(TARGET_LD, "PowerUp", None)
|
||||
else:
|
||||
return await self._send_cmd(TARGET_LD, "PowerDown", None)
|
||||
|
||||
async def set_default_pwr_on(self, on):
|
||||
"""
|
||||
Set whether laser diode is powered up at Startup
|
||||
- on (True/False)
|
||||
"""
|
||||
return await self._send_cmd(TARGET_LD, "SetDefaultPowerOn", on)
|
||||
|
||||
async def set_ld_terms_short(self, short):
|
||||
"""
|
||||
Open/Short laser diode terminals.
|
||||
- on (True/False)
|
||||
"""
|
||||
if short:
|
||||
return await self._send_cmd(TARGET_LD, "LdTermsShort", None)
|
||||
else:
|
||||
return await self._send_cmd(TARGET_LD, "LdTermsOpen", None)
|
||||
|
||||
async def set_i(self, i):
|
||||
"""
|
||||
Set laser diode output current: Max(0, Min(i_set, i_soft_limit))
|
||||
- i: mA
|
||||
"""
|
||||
return await self._send_cmd(TARGET_LD, "SetI", i)
|
||||
|
||||
async def set_i_soft_limit(self, i_limit):
|
||||
"""
|
||||
Set laser diode software output current limit
|
||||
- i_limit: mA
|
||||
"""
|
||||
return await self._send_cmd(TARGET_LD, "SetISoftLimit", i_limit)
|
||||
|
||||
async def config_pd_mon(self, responsitivity, dark_current):
|
||||
"""
|
||||
Configure the photodiode monitor parameters
|
||||
- responsitivity: A/W
|
||||
- dark current: uA
|
||||
"""
|
||||
response = await self._send_cmd(TARGET_LD, "SetPdResponsitivity", responsitivity)
|
||||
if response["msg_type"] != "Acknowledge":
|
||||
return response
|
||||
return await self._send_cmd(TARGET_LD, "SetPdDarkCurrent", dark_current)
|
||||
|
||||
async def set_ld_pwr_limit(self, pwr_limit):
|
||||
"""
|
||||
Set power limit for the power excursion monitor
|
||||
If the calculated power with the params of pd_mon > pwr_limit,
|
||||
overpower protection is triggered.
|
||||
- pwr_limit: mW
|
||||
"""
|
||||
return await self._send_cmd(TARGET_LD, "SetLdPwrLimit", pwr_limit)
|
||||
|
||||
async def clear_alarm(self):
|
||||
"""
|
||||
Clear the power excursion monitor alarm
|
||||
"""
|
||||
return await self._send_cmd(TARGET_LD, "ClearAlarm")
|
||||
|
||||
class Thermostat:
|
||||
def __init__(self, send_cmd_handler, send_raw_cmd_handler):
|
||||
self._send_cmd = send_cmd_handler
|
||||
self._send_raw_cmd = send_raw_cmd_handler
|
||||
|
||||
async def set_power_on(self, on):
|
||||
"""
|
||||
Power up or power down thermostat
|
||||
- Powering up the thermostat resets the pwr_excursion status
|
||||
"""
|
||||
if on:
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "PowerUp", None)
|
||||
else:
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "PowerDown", None)
|
||||
|
||||
async def set_default_pwr_on(self, on):
|
||||
"""
|
||||
Set whether thermostat is powered up at Startup
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetDefaultPowerOn", on)
|
||||
|
||||
async def set_tec_max_v(self, max_v):
|
||||
"""
|
||||
Set Tec Maximum Voltage Across the TEC Terminals
|
||||
- max_v: V
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetTecMaxV", max_v)
|
||||
|
||||
async def set_tec_max_i_pos(self, max_i_pos):
|
||||
"""
|
||||
Set Tec maximum positive output
|
||||
- max_i_pos: A
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetTecMaxIPos", max_i_pos)
|
||||
|
||||
async def set_tec_max_i_neg(self, max_i_neg):
|
||||
"""
|
||||
Set Tec maximum negative output
|
||||
- max_i_neg: A
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetTecMaxINeg", max_i_neg)
|
||||
|
||||
async def set_tec_i_out(self, i_out):
|
||||
"""
|
||||
Set Tec Output Current
|
||||
This cmd is only effective in constant current control mode
|
||||
or your newly set value will be overwritten by PID Controller Output
|
||||
- i_out: A
|
||||
"""
|
||||
if isinstance(i_out, float):
|
||||
return await self._send_raw_cmd({"tec_set_i": i_out})
|
||||
elif isinstance(i_out, int):
|
||||
return await self._send_raw_cmd({"tec_set_i": float(i_out)})
|
||||
else:
|
||||
raise InvalidDataType
|
||||
|
||||
async def set_constant_current_control_mode(self):
|
||||
"""
|
||||
Disable PID Controller and output current can be controlled with set_tec_i_out() cmd.
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetPidDisEngage", None)
|
||||
|
||||
async def set_temperature_setpoint(self, temperature):
|
||||
"""
|
||||
Set Temperature Setpoint for PID Controller. This parameter is not active in constant current control mode
|
||||
- temperature: Degree Celsius
|
||||
"""
|
||||
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetTemperatureSetpoint", temperature)
|
||||
|
||||
async def set_pid_control_mode(self):
|
||||
"""
|
||||
Enable PID Controller. Its PID Update Interval is controlled by the Temperature ADC polling rate.
|
||||
Please refer to config_temp_adc_filter for the possible polling rate options
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetPidEngage", None)
|
||||
|
||||
async def set_pid_kp(self, kp):
|
||||
"""
|
||||
Set Kp parameter for PID Controller
|
||||
kp: (unitless)
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetPidKp", kp)
|
||||
|
||||
async def set_pid_ki(self, ki):
|
||||
"""
|
||||
Set Ki parameter for PID Controller
|
||||
ki: (unitless)
|
||||
"""
|
||||
await self._send_cmd(TARGET_THERMOSTAT, "SetPidKi", ki)
|
||||
|
||||
async def set_pid_kd(self, kd):
|
||||
"""
|
||||
Set Kd parameter for PID Controller
|
||||
kd: (unitless)
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetPidKd", kd)
|
||||
|
||||
async def set_pid_output_max(self, out_max):
|
||||
"""
|
||||
Set max output limit at the PID Output
|
||||
- out_max: A
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetPidOutMax", out_max)
|
||||
|
||||
async def set_pid_output_min(self, out_min):
|
||||
"""
|
||||
Set min output limit at the PID Output
|
||||
- out_min: A
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetPidOutMin", out_min)
|
||||
|
||||
async def set_temp_mon_upper_limit(self, upper_limit):
|
||||
"""
|
||||
Set Temperature Monitor Upper Limit Threshold. Exceeding the limit for too long
|
||||
will force the TEC Controller, PID Controller and Laser Diode Power to Shutdown
|
||||
- upper_limit: Degree Celsius
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetTempMonUpperLimit", upper_limit)
|
||||
|
||||
async def set_temp_mon_lower_limit(self, lower_limit):
|
||||
"""
|
||||
Set Temperature Monitor Lower Limit Threshold. Exceeding the limit for too long
|
||||
will force the TEC Controller, PID Controller and Laser Diode Power to Shutdown
|
||||
- lower_limit: Degree Celsius
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetTempMonLowerLimit", lower_limit)
|
||||
|
||||
async def clear_alarm(self):
|
||||
"""
|
||||
Clear the temperature monitor alarm
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "ClearAlarm")
|
||||
|
||||
async def set_sh_t0(self, t0):
|
||||
"""
|
||||
Set t0 Steinhart-Hart parameter for the laser diode NTC
|
||||
- t0: Degree Celsius
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetShT0", t0)
|
||||
|
||||
async def set_sh_r0(self, r0):
|
||||
"""
|
||||
Set r0 Steinhart-Hart parameter for the laser diode NTC
|
||||
- r0: Ohm
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetShR0", r0)
|
||||
|
||||
async def set_sh_beta(self, beta):
|
||||
"""
|
||||
Set beta Steinhart-Hart parameter for the laser diode NTC
|
||||
- beta: (unitless)
|
||||
"""
|
||||
return await self._send_cmd(TARGET_THERMOSTAT, "SetShBeta", beta)
|
||||
|
||||
async def config_temp_adc_filter(self, filter_type, sampling_rate):
|
||||
"""
|
||||
Configure the temperature adc filter type and sampling rate.
|
||||
Please refer to AD7172 datasheet for the usage of various types of filter.
|
||||
The actual temperature polling rate is bottlenecked by the processing speed of the MCU and
|
||||
performs differently under different kinds of workload. Please verify the polling rate with
|
||||
the timestamp.
|
||||
"""
|
||||
if not(filter_type in Filter_Config.keys()):
|
||||
raise InvalidDataType
|
||||
if Filter_Config[filter_type][1] != DATA_F32:
|
||||
if not(sampling_rate in Filter_Config[filter_type][1]):
|
||||
raise InvalidDataType
|
||||
else:
|
||||
if not(isinstance(sampling_rate, float)):
|
||||
raise InvalidDataType
|
||||
|
||||
cmd = {}
|
||||
cmd["thermostat_cmd"] = "ConfigTempAdcFilter"
|
||||
cmd["temp_adc_filter"] = {
|
||||
"filter_type": filter_type,
|
||||
Filter_Config[filter_type][0]: sampling_rate,
|
||||
}
|
||||
|
||||
return await self._send_raw_cmd(cmd)
|
||||
|
||||
class Kirdy:
|
||||
def __init__(self):
|
||||
self._reader = None
|
||||
self._writer = None
|
||||
self._connecting_task = None
|
||||
self._cmd_lock = asyncio.Lock()
|
||||
self._report_mode_on = False
|
||||
self.timeout = None
|
||||
self.device = Device(self._send_cmd_handler, self._send_raw_cmd_handler, self._read_response)
|
||||
self.laser = Laser(self._send_cmd_handler)
|
||||
self.thermostat = Thermostat(self._send_cmd_handler, self._send_raw_cmd_handler)
|
||||
|
||||
self._cmd_list = {
|
||||
TARGET_DEVICE: {
|
||||
"SetIPSettings": IP_SETTINGS,
|
||||
"SetActiveReportMode": DATA_BOOL,
|
||||
"GetStatusReport": None,
|
||||
"GetSettingsSummary": None,
|
||||
"Dfu": None,
|
||||
"SaveFlashSettings": None,
|
||||
"LoadFlashSettings": None,
|
||||
"HardReset": None,
|
||||
},
|
||||
TARGET_LD: {
|
||||
# LD Drive Related
|
||||
"SetDefaultPowerOn": DATA_BOOL,
|
||||
"PowerUp": None,
|
||||
"PowerDown": None,
|
||||
"LdTermsShort": None,
|
||||
"LdTermsOpen": None,
|
||||
"SetI": DATA_F32,
|
||||
"SetISoftLimit": DATA_F32,
|
||||
# PD Mon Related
|
||||
"SetPdResponsitivity": DATA_F32,
|
||||
"SetPdDarkCurrent": DATA_F32,
|
||||
"SetLdPwrLimit": DATA_F32,
|
||||
"ClearAlarm": None,
|
||||
},
|
||||
TARGET_THERMOSTAT: {
|
||||
"SetDefaultPowerOn": DATA_BOOL,
|
||||
"PowerUp": DATA_F32,
|
||||
"PowerDown": DATA_F32,
|
||||
# TEC Controller Settings
|
||||
"SetTecMaxV": DATA_F32,
|
||||
"SetTecMaxIPos": DATA_F32,
|
||||
"SetTecMaxINeg": DATA_F32,
|
||||
"SetTecIOut": DATA_F32,
|
||||
"SetTemperatureSetpoint": DATA_F32,
|
||||
# PID Controller Settings
|
||||
"SetPidEngage": None,
|
||||
"SetPidDisEngage": None,
|
||||
"SetPidKp": DATA_F32,
|
||||
"SetPidKi": DATA_F32,
|
||||
"SetPidKd": DATA_F32,
|
||||
"SetPidOutMin": DATA_F32,
|
||||
"SetPidOutMax": DATA_F32,
|
||||
# Temperature Adc Internal Filters Settings
|
||||
"ConfigTempAdcFilter": TEMP_ADC_FILTER,
|
||||
# Temperature Monitor Settings
|
||||
"SetTempMonUpperLimit": DATA_F32,
|
||||
"SetTempMonLowerLimit": DATA_F32,
|
||||
"ClearAlarm": None,
|
||||
# Thermistor Parameter Settings
|
||||
"SetShT0": DATA_F32,
|
||||
"SetShR0": DATA_F32,
|
||||
"SetShBeta": DATA_F32,
|
||||
}
|
||||
}
|
||||
|
||||
async def start_session(self, host='192.168.1.128', port=1337, timeout=None):
|
||||
self._connecting_task = asyncio.create_task(
|
||||
asyncio.wait_for(asyncio.open_connection(host, port), timeout)
|
||||
)
|
||||
self.timeout = timeout
|
||||
try:
|
||||
self._reader, self._writer = await self._connecting_task
|
||||
writer_sock = self._writer.get_extra_info("socket")
|
||||
writer_sock.setsockopt(socket.IPPROTO_TCP, socket.TCP_NODELAY, 1)
|
||||
|
||||
except asyncio.CancelledError:
|
||||
raise StoppedConnecting
|
||||
finally:
|
||||
self._connecting_task = None
|
||||
|
||||
def connecting(self):
|
||||
"""Returns True if client is connecting"""
|
||||
return self._connecting_task is not None
|
||||
|
||||
def connected(self):
|
||||
"""Returns True if client is connected"""
|
||||
return self._writer is not None
|
||||
|
||||
async def _cmd(self, *cmd):
|
||||
async with self._cmd_lock:
|
||||
# protect the read-write process from being cancelled midway
|
||||
line = await asyncio.shield(self._read_write(cmd))
|
||||
|
||||
async def end_session(self):
|
||||
"""End session to Thermostat if connected, cancel connection if connecting"""
|
||||
if self._connecting_task is not None:
|
||||
self._connecting_task.cancel()
|
||||
|
||||
if self._writer is None:
|
||||
return
|
||||
|
||||
# Reader needn't be closed
|
||||
self._writer.close()
|
||||
await self._writer.wait_closed()
|
||||
self._reader = None
|
||||
self._writer = None
|
||||
|
||||
async def _read_response(self):
|
||||
try:
|
||||
response = await asyncio.wait_for(self._reader.read(1024), self.timeout)
|
||||
except TimeoutError:
|
||||
return {
|
||||
"msg_type": "Internal Timeout"
|
||||
}
|
||||
response = response.decode('utf-8', errors='ignore')
|
||||
try:
|
||||
return json.loads(response)
|
||||
except json.decoder.JSONDecodeError:
|
||||
return {
|
||||
"msg_type": "Internal Invalid"
|
||||
}
|
||||
|
||||
# If the cmd involves a cmd specific data type,
|
||||
# checking is done separately within the functions being called
|
||||
async def _send_raw_cmd_handler(self, cmd):
|
||||
retry = 0
|
||||
while retry < 10:
|
||||
self._writer.write(bytes(json.dumps(cmd), "UTF-8"))
|
||||
await self._writer.drain()
|
||||
response = await self._read_response()
|
||||
try:
|
||||
if response["msg_type"] == "Acknowledge":
|
||||
return response
|
||||
except:
|
||||
retry += 1
|
||||
await asyncio.sleep(0.25)
|
||||
raise NoAckRecv
|
||||
|
||||
async def _send_cmd_handler(self, target, cmd, data=None):
|
||||
cmd_dict = {}
|
||||
|
||||
if not(target in self._cmd_list.keys()) or not(cmd in self._cmd_list[target].keys()):
|
||||
raise CmdDoesNotExist
|
||||
cmd_dict[target] = cmd
|
||||
|
||||
if self._cmd_list[target][cmd] == DATA_F32:
|
||||
if isinstance(data, float):
|
||||
cmd_dict[DATA_F32] = data
|
||||
elif isinstance(data, int):
|
||||
cmd_dict[DATA_F32] = float(data)
|
||||
elif self._cmd_list[target][cmd] == DATA_BOOL:
|
||||
if isinstance(data, bool):
|
||||
cmd_dict[DATA_BOOL] = data
|
||||
else:
|
||||
raise InvalidDataType
|
||||
elif self._cmd_list[target][cmd] == None:
|
||||
pass
|
||||
else:
|
||||
# Undefined Data Type
|
||||
raise CmdDoesNotExist
|
||||
|
||||
retry = 0
|
||||
while retry < 10:
|
||||
self._writer.write(bytes(json.dumps(cmd_dict), "UTF-8"))
|
||||
await self._writer.drain()
|
||||
response = await self._read_response()
|
||||
try:
|
||||
if response["msg_type"] == "Acknowledge":
|
||||
return response
|
||||
except:
|
||||
retry += 1
|
||||
await asyncio.sleep(0.1)
|
||||
raise NoAckRecv
|
||||
|
||||
async def report_mode(self):
|
||||
"""Start reporting device status in json object
|
||||
|
||||
Example of yielded data::
|
||||
{
|
||||
'ts': 227657, # Relative Timestamp (ms)
|
||||
'laser': {
|
||||
'pwr_on': False, # Laser Power is On (True/False)
|
||||
'pwr_excursion': False, # Was Laser experienced an Overpowered Condition? (True/False)
|
||||
'ld_i_set': 0.0, # Laser Diode Output Current (A)
|
||||
'pd_i': 2.0000002e-06, # Internal Photodiode Monitor current (A)
|
||||
'pd_pwr': None, # Power Readings from Internal Photodiode (W). Return None if pd_mon parameter(s) are not defined.
|
||||
'term_status': 'Is50Ohm' # Is the Low Frequency Modulation Input's Impedance 50 Ohm? (Is50Ohm/Not50Ohm)
|
||||
},
|
||||
'tec': {
|
||||
'pwr_on': False, # Tec Power is On (True/False)
|
||||
'pid_engaged': False, # Is Pid_Engaged. If False, it is in Constant Current Mode (True/False)
|
||||
'temp_mon_status': { # Temperature Monitor:
|
||||
'status': 'Off', # (To be revised)
|
||||
'over_temp_alarm': False # Was Laser Diode experienced an Overtemperature condition (True/False)
|
||||
},
|
||||
'temperature': 298.18344, # Temperature Readings (K)
|
||||
'i_set': 0.0, # Tec Current Set by User/PID Controller(A)
|
||||
'tec_i': 0.0024998188, # Tec Current Readings (A)
|
||||
'tec_v': -0.00399971 # Tec Voltage Readings (V)
|
||||
}
|
||||
}
|
||||
"""
|
||||
await self.device.set_active_report_mode(True)
|
||||
self._report_mode_on = True
|
||||
|
||||
while self._report_mode_on:
|
||||
async with self._cmd_lock:
|
||||
yield await self._read_response()
|
||||
|
||||
await self.device.set_active_report_mode(False)
|
||||
|
||||
def stop_report_mode(self):
|
||||
self._report_mode_on = False
|
Loading…
Reference in New Issue
Block a user