@ -1,20 +1,22 @@
|
||||
use super::{Channel, Error};
|
||||
|
||||
/// Provide an interface to measure RF input power in dB.
|
||||
/// Provide an interface to measure RF input power in dBm.
|
||||
pub trait PowerMeasurementInterface {
|
||||
fn sample_converter(&mut self, channel: Channel) -> Result<f32, Error>;
|
||||
|
||||
/// Measure the power of an input channel in dBm.
|
||||
///
|
||||
/// Note: This function assumes the input channel is connected to an AD8363 output.
|
||||
///
|
||||
/// Args:
|
||||
/// * `channel` - The pounder channel to measure the power of in dBm.
|
||||
/// * `channel` - The pounder input channel to measure the power of.
|
||||
///
|
||||
/// Returns:
|
||||
/// Power in dBm after the digitally controlled attenuator before the amplifier.
|
||||
fn measure_power(&mut self, channel: Channel) -> Result<f32, Error> {
|
||||
let analog_measurement = self.sample_converter(channel)?;
|
||||
|
||||
// The AD8363 with VSET connected to VOUT provides an output voltage of 51.7mV / dB at
|
||||
// 100MHz. It also indicates a y-intercept of -58dBm.
|
||||
Ok(analog_measurement / 0.0517 - 58.0)
|
||||
// The AD8363 with VSET connected to VOUT provides an output voltage of 51.7 mV/dB at
|
||||
// 100MHz with an intercept of -58 dBm.
|
||||
// It is placed behind a 20 dB tap.
|
||||
Ok(analog_measurement * (1. / 0.0517) + (-58. + 20.))
|
||||
}
|
||||
}
|
||||
|