let anode_cathode = 20.0;
|
/*
|
||||||
let cathode_bias = 12.0;
|
// ZJ-10
|
||||||
loop_anode.set_target(anode_cathode+cathode_bias);
|
let anode = 165.0;
|
||||||
loop_cathode.set_emission_target(anode_cathode/10000.0);
|
let cathode_bias = 50.0;
|
||||||
|
let emission = 0.5e-3;
|
||||||
|
*/
|
||||||
|
/*
|
||||||
|
// ZJ-27
|
||||||
|
let anode = 225.0;
|
||||||
|
let cathode_bias = 25.0;
|
||||||
|
let emission = 1.0e-3;
|
||||||
|
*/
|
||||||
|
// ZJ-12
|
||||||
|
let anode = 200.0;
|
||||||
|
let cathode_bias = 50.0;
|
||||||
|
let emission = 4.0e-3;
|
||||||
|
loop_anode.set_target(anode);
|
||||||
|
loop_cathode.set_emission_target(emission);
|
||||||
loop_cathode.set_bias_target(cathode_bias);
|
loop_cathode.set_bias_target(cathode_bias);
|
||||||
});
|
});
|
||||||
|
|
||||||
|
|