#!/bin/sh
|
|
|
|
# tnetplug host
|
|
export TNETPLUG_HOST=192.168.1.31
|
|
export TNETPLUG_PORT=3131
|
|
|
|
# Smart USB hub host
|
|
# (uhubctl must be installed on the host)
|
|
export HOST=rpi-3
|
|
export HOSTPORT=22
|
|
# Hub port where the RedPitaya is connected
|
|
export HUBPORT=4
|
|
|
|
# Simultaneously, start testing RP's network connectivity, while
|
|
# powering on MCH using tnetplug, and RP using uhubctl
|
|
# Display power-on time
|
|
TIMESTAMP_PRETTY=$(date '+%Y-%m-%d %H:%M:%S')
|
|
echo "MCH powered on at $TIMESTAMP_PRETTY."
|
|
# Power on MCH
|
|
echo "A" | nc -W1 $TNETPLUG_HOST $TNETPLUG_PORT &
|
|
# Power on RedPitaya connected to the smart USB hub
|
|
# (assume that only 1 hub is connected)
|
|
ssh -p $HOSTPORT $HOST "uhubctl -a on -p $HUBPORT" &
|
|
# Wait 2 minutes before measurement
|
|
sleep 120
|
|
|
|
# Get and plot Sayma data
|
|
# NOTE: Change the RP hostname and LV/HV arguments according to
|
|
# which two channels you are measuring!
|
|
nix-shell -p python3Packages.matplotlib python3Packages.numpy python3Packages.scipy --run "./get_and_plot_sayma_data mlabs-raw mlabs-1 1 mlabs-1 2 mlabs-1:LV,LV" &
|
|
# Wait 1 minute before powering off MCH and RP
|
|
sleep 60
|
|
|
|
# Wait 30 seconds
|
|
sleep 30
|
|
|
|
# Simultaneously power off MCH and RP
|
|
# Display power-off time
|
|
TIMESTAMP_PRETTY=$(date '+%Y-%m-%d %H:%M:%S')
|
|
echo "MCH powered off at $TIMESTAMP_PRETTY."
|
|
# Power off MCH
|
|
echo "a" | nc -W1 $TNETPLUG_HOST $TNETPLUG_PORT &
|
|
# Power off RedPitaya connected to the smart USB hub
|
|
ssh -p $HOSTPORT $HOST "uhubctl -a off -p $HUBPORT"
|