2021-04-28 21:57:58 +08:00
## Scripts
### Python
(To see detailed usage, add `--help` as an argument when running the script.)
* `rp_get_sayma_data.py`: Acquire and save data from RedPitayas over local network
* `plot_sayma_data.py`: Load saved data and output phase skew analysis and data plots
### Shell
* `mch_start`: Power on the MCH and start logging serial outputs from Metlino and Saymas
* `mch_stop`: Power off the MCH and stop logging serial outputs from Metlino and Saymas
2021-05-13 10:34:47 +08:00
* `rp_ping_test`: Loop to ping a RedPitaya until it succeeds
* The exit condition is where the RedPitaya is ready-to-use
* `rp_shutdown`: Shut down the OS of a RedPitaya and loop to ping it until it fails
* The exit condition is where the RedPitaya is ready for hardware power-off
2021-04-28 21:57:58 +08:00
* `get_and_plot_sayma_data`: Acquire and analyse data from RedPitayas over local network
* `get_and_plot_remote_sayma_data`: Acquire and analyse data from remote RedPitayas via SSH (often over different networks) to the local file system
* Requires Python testsuite scripts present on the remote host