Compare commits

..

2 Commits

Author SHA1 Message Date
11131deda2 README: Add PID Output Clamping section
Explains the need of having separate "max_i_pos/output_max" and
"max_i_neg/output_min" values; They serve different purposes.
2024-11-20 08:02:07 +08:00
764774fbce PyThermostat: Remove report mode in autotune.py 2024-11-18 17:47:33 +08:00
2 changed files with 22 additions and 2 deletions

View File

@ -239,6 +239,22 @@ of channel 0 to the PID algorithm:
output 0 pid
```
### PID output clamping
It is possible to clamp the PID algorithm output independently of channel output limits. This is desirable when e.g. there is a need to keep the current value above a certain threshold in closed-loop mode.
Note that the actual output will still ultimately be limited by the `max_i_pos` and `max_i_neg` values.
Set PID maximum output of channel 0 to 1.5 A.
```
pid 0 output_max 1.5
```
Set PID minimum output of channel 0 to 0.1 A.
```
pid 0 output_min 0.1
```
## LED indicators
| Name | Color | Meaning |

View File

@ -1,5 +1,6 @@
import math
import logging
import time
from collections import deque, namedtuple
from enum import Enum
@ -236,13 +237,14 @@ def main():
tec = Client()
data = next(tec.report_mode())
data = tec.get_report()
ch = data[channel]
tuner = PIDAutotune(target_temperature, output_step,
lookback, noiseband, ch['interval'])
for data in tec.report_mode():
while True:
data = tec.get_report()
ch = data[channel]
@ -255,6 +257,8 @@ def main():
tec.set_param("output", channel, "i_set", tuner_out)
time.sleep(0.05)
tec.set_param("output", channel, "i_set", 0)