9ede52de93
Fix updating status label for hwrev = None
2024-10-07 17:48:24 +08:00
66db9bcc57
Put some menu requests in menu itself
2024-10-07 17:48:24 +08:00
f29095a0da
Broadcast ConnectionState changes from Thermostat
2024-10-07 17:48:24 +08:00
7e235c3fea
Move sigActivatedHandle to CtrlPanel
2024-10-07 17:48:24 +08:00
e82e561d14
Get rid of timeout on readline
2024-10-07 17:48:24 +08:00
7ec7ae7329
Put send_command in CtrlPanel
2024-10-07 17:48:24 +08:00
9f0064a61c
Extra bail removed
2024-10-07 17:48:24 +08:00
d8c7db3f66
return hwrev when start_session
2024-10-07 17:48:24 +08:00
254e391a09
state str
2024-10-07 17:48:24 +08:00
f6276cdd74
params update concurrently
2024-10-07 17:48:24 +08:00
b380d66750
Stuff non-UI changes in Thermostat model
2024-10-07 17:48:24 +08:00
56c3e30c6b
Base Thermostat connectivity UI changes to state
2024-10-07 17:48:24 +08:00
5c6652cdcb
Remove wait_for
...
OSError raised anyways
2024-10-07 17:48:24 +08:00
bfc3543972
Actually its OSError
2024-10-07 17:48:24 +08:00
eb9189247f
{start,end}_session -> [dis]connect
2024-10-07 17:48:24 +08:00
05dd0afe03
Simplify on_connect_btn_clicked
...
Raise if OSError
2024-10-07 17:48:24 +08:00
af53926b01
Connecting task moved?
2024-10-07 17:48:24 +08:00
371ddcdc5b
AsyncIO version Client -> AsyncioClient
2024-10-07 17:48:24 +08:00
f66d029915
Exclusively use the Thermostat object as a medium
...
All calls to the Thermostat should be forwarded by the medium.
2024-10-07 17:48:24 +08:00
cf39eee997
Integrate WrappedClient into Thermostat model
2024-10-07 17:48:24 +08:00
87ef1caf47
Should not stop cancelling read if timeout'd
2024-10-07 17:48:24 +08:00
9d271f97a2
Fix Autotuner state for forceful disconnect
2024-10-07 17:48:24 +08:00
6c09ce1be0
_
2024-10-07 17:48:24 +08:00
8ab93591a3
Make connection loss handling more elegant
...
Show an info box on connection lost informing the user that the
Thermostat was forcefully disconnected.
2024-10-07 17:48:24 +08:00
c2952f881f
Use new style super()
2024-10-07 17:48:24 +08:00
810237bccf
Move command line host:port setting handling
...
To main
2024-10-07 17:48:24 +08:00
f9b1bf8c6c
aioclient: Add missing readline for saving
...
Saving all channels returns multiple JSON objects, read the extra {}.
2024-10-07 17:48:24 +08:00
23aafeba08
import order rearrange
2024-10-07 17:48:24 +08:00
334c4dbdce
This is bail
2024-10-07 17:48:24 +08:00
56b2ecfc9b
thermostat: Properly register task
...
Also Thermostat.task -> Thermostat._update_params_task
2024-10-07 17:48:24 +08:00
de583c38c4
ip -> host
2024-10-07 17:48:24 +08:00
5f69cb55e7
Lazy evaluating for debug string command
2024-10-07 17:48:24 +08:00
4ccddf9f20
Add pytec runnables
2024-10-07 17:48:24 +08:00
585c33cabb
Exactlier wording
2024-10-07 17:48:24 +08:00
7696a07b4a
unused
2024-10-07 17:48:24 +08:00
2eb7eb40a2
encoding
2024-10-07 17:48:24 +08:00
206b825e88
Just catch asyncio.TimeoutError
...
Will just change to TimeoutError once we switch to Python 3.11 in the
flake.
2024-10-07 17:48:24 +08:00
4a038d04d1
Remove exception too general
2024-10-07 17:48:24 +08:00
8599c5be4e
Use asserts to check for connectivity
2024-10-07 17:48:24 +08:00
99777d75ce
Add back the parent
2024-10-07 17:48:24 +08:00
b6696c2b09
Fix method call
2024-10-07 17:48:24 +08:00
35a447e980
Swap order arounda bit more
2024-10-07 17:48:24 +08:00
f19809c852
Formatting
2024-10-07 17:48:24 +08:00
c9aa0eaab8
ctrl_panel: Reformat SpinBox text always if valid
...
The parameter SpinBoxes previously would only update if the interpreted
value was changed, missing cases where the text would have changed but
the value stays the same, e.g. removing trailing decimal zeros.
2024-10-07 16:13:56 +08:00
ed6cee4394
ctrl_panel: Move postfilter into its own group
2024-10-07 16:13:56 +08:00
e1bd960900
ctrl_panel: Use new locking mechanism from Kirdy
2024-10-07 16:13:56 +08:00
aed0c484dd
ctrl_panel: Fix editing fields with unit "°C"
...
A faulty regular expression within PyQtGraph causes any Parameter with a
suffix that doesn't begin with an alphanumeric character (as matched
with \w) to act abnormally. For instance, entering "100 °C" into the
input boxes gets interpreted as 10 °C.
Patch the FLOAT_REGEX in PyQtGraph to simply match for any character in
the suffix group.
2024-10-07 16:13:56 +08:00
3fe343435d
ctrl_panel: More appropriate steps and fixes
2024-10-07 16:13:56 +08:00
eddfc40e07
ctrl_panel: Put plotted values into readings group
...
For more intuitiveness to first-time users
2024-10-07 16:13:56 +08:00
3ae89760ab
ctrl_panel: Fix max_v to only have unit "V"
...
As most users do not need to limit TEC voltage with accuracy of less
than 1mV.
2024-10-07 16:13:56 +08:00