Author SHA1 Message Date
87ba107ce5 ctrl_panel: Indicate active parameter of control
Instead of hiding the inactive control parameter, underline and bold the
active control parameter title, e.g. "Set Current" when control method
is constant current, and "Setpoint" when it is temperature PID.
2024-08-16 14:05:44 +08:00
f7c266539b ctrl_panel: Code cleanup
* Remove unnecessary duplication of `THERMOSTAT_PARAMETERS`

* i -> ch

* Separate ParameterTree and Parameter initiation

* Remove extra "channel" option to root parameters, as the "value"
option is already the channel number
2024-08-16 14:05:44 +08:00
df9715b3ef ctrl_panel: PID Auto Tune -> PID Autotune 2024-08-16 14:05:44 +08:00
d3b93b1263 ctrl_panel: Remove need for "mA" hack
Remove all instances of mA scaling scattered all around the code and
specify it in the parameter tree with a single source of truth.

Done by adding the option "pinSiPrefix" for all Parameters of type `int`
or `float`, and using it for current Parameters with unit "mA".
2024-08-16 14:05:44 +08:00
437c9cec34 ctrl_panel: Refer to Parameters by concise names
For displayed string representations, use the `title` key, or for
`ListParameter`s, use the dictionary mapping method instead.
2024-07-19 15:49:19 +08:00
7829ce6adf ctrl_panel: Config -> Settings 2024-07-19 15:49:16 +08:00
d244ba392a Fix typos 2024-07-19 15:34:31 +08:00
271fe449ba Remove duplicated show call
MainWindow.show() already called in coro_main
2024-07-10 15:56:43 +08:00
70db0a39eb Remove duplicated antialias config option
Already set in live_plot_view.py
2024-07-10 15:56:43 +08:00
26c7382b1e Move GUI components and examples into folder
For better organisation
2024-07-10 15:56:43 +08:00
1707728c3c thermostat_data_model.py -> thermostat.py 2024-07-10 15:56:34 +08:00
a16d2e9a9e Follow CapWords convention for class names
Re: PEP8
2024-07-10 15:45:03 +08:00
bc4ac43e0b Put comments in right place 2024-07-10 13:07:31 +08:00
9acff86547 Restructure GUI Code, Improve and Fix Bugs
- Bugs fix:
1. Params Tree user input will not get overwritten
    by incoming report thermostat_data_model.
2. PID Autotune Sampling Period is now set according to Thermostat sampling interval
3. PID Autotune won't get stuck in Fail State
4. Various types disconnection related Bugs
5. Number of Samples stored in the plot cannot be set
6. Limit the max settable output current to be 2000mA

- Improvement:
1. Params Tree settings can be changed with external json
2. Use a Tab system to show a single channel of config instead of two
3. Expose PID Autotune lookback params
4. Icon is changed to Artiq logo

- Restructure:
1. Restructure the code to follow Model-View-Delegate Design Pattern
2024-06-06 17:34:15 +08:00
8753f4a0fc Finish GUI 2024-05-08 14:49:03 +08:00
9a83d6850d Remove unused as clause 2024-05-08 14:49:03 +08:00
772863f4b2 Add paramtree view, without updates
Signed-off-by: Egor Savkin <es@m-labs.hk>

Fix signal blocker argument -atse
2024-05-08 14:49:03 +08:00
44ef2c04e3 Fix bugs, grammar, text, and refactor into class 2024-05-08 14:49:03 +08:00
400f3a98e8 Stop polling drift
Just waiting for the update_s doesn't take into account the time to
execute update_params, and causes time drift.
2024-05-08 14:49:03 +08:00
7dd5d15047 Remove unused 'as' clause 2024-05-08 14:49:03 +08:00
65e1f4a146 Finish moving over to qasync
Also:

* Add aioclient

The old client is synchronous and blocking, and the only way to achieve
true asynchronous IO is to create a new client that interfaces with
asyncio.

* Finish Nix Flake description and make the GUI available for `nix run`
2024-05-08 14:49:03 +08:00
e0ce14c616 Try move from Qthreads to qasync
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
a79679a074 Create client watcher, that would poll Thermostat for config
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
b9acba69d3 Create basic GUI, that would connect and control thermostat's fan
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00