08925755a3
Just catch asyncio.TimeoutError
...
Will just change to TimeoutError once we switch to Python 3.11 in the
flake.
2024-07-16 13:28:47 +08:00
3d41254f43
Integrate WrappedClient into Thermostat model
2024-07-16 13:28:47 +08:00
a64532eb23
Fix Autotuner state for forceful disconnect
2024-07-16 13:28:47 +08:00
0f708c0298
Formatting
2024-07-16 13:28:11 +08:00
01e4ff8dd5
Use asserts to check for connectivity
2024-07-16 13:27:29 +08:00
b37dc49915
Swap order arounda bit more
2024-07-16 13:26:33 +08:00
e1565e2dfc
Try make the i_set parameter adjustable pid
...
"Auto" box
2024-07-16 13:23:56 +08:00
fda4cc9bfb
Make connection loss handling more elegant
...
Show an info box on connection lost informing the user that the
Thermostat was forcefully disconnected.
2024-07-16 13:23:12 +08:00
d68ff0e182
$ch
2024-07-16 13:23:12 +08:00
977261e684
Fix grammar in info box on PID Autotune failure
2024-07-16 11:32:34 +08:00
ddeb5e988e
ctrl_panel: Pin down units for editable fields
...
Avoids awkward value editing
2024-07-16 11:32:31 +08:00
30ba8260d0
ctrl_panel: Refer to Parameters by concise name
s
...
For displayed string representations, use the `title` key, or for
`ListParameter`s, use the dictionary mapping method instead.
2024-07-15 12:23:01 +08:00
27cc68e524
ctrl_panel: Config -> Settings
2024-07-12 17:45:59 +08:00
271fe449ba
Remove duplicated show call
...
MainWindow.show() already called in coro_main
2024-07-10 15:56:43 +08:00
70db0a39eb
Remove duplicated antialias config option
...
Already set in live_plot_view.py
2024-07-10 15:56:43 +08:00
26c7382b1e
Move GUI components and examples into folder
...
For better organisation
2024-07-10 15:56:43 +08:00
1707728c3c
thermostat_data_model.py -> thermostat.py
2024-07-10 15:56:34 +08:00
a16d2e9a9e
Follow CapWords convention for class names
...
Re: PEP8
2024-07-10 15:45:03 +08:00
bc4ac43e0b
Put comments in right place
2024-07-10 13:07:31 +08:00
9acff86547
Restructure GUI Code, Improve and Fix Bugs
...
- Bugs fix:
1. Params Tree user input will not get overwritten
by incoming report thermostat_data_model.
2. PID Autotune Sampling Period is now set according to Thermostat sampling interval
3. PID Autotune won't get stuck in Fail State
4. Various types disconnection related Bugs
5. Number of Samples stored in the plot cannot be set
6. Limit the max settable output current to be 2000mA
- Improvement:
1. Params Tree settings can be changed with external json
2. Use a Tab system to show a single channel of config instead of two
3. Expose PID Autotune lookback params
4. Icon is changed to Artiq logo
- Restructure:
1. Restructure the code to follow Model-View-Delegate Design Pattern
2024-06-06 17:34:15 +08:00
8753f4a0fc
Finish GUI
2024-05-08 14:49:03 +08:00
9a83d6850d
Remove unused as clause
2024-05-08 14:49:03 +08:00
772863f4b2
Add paramtree view, without updates
...
Signed-off-by: Egor Savkin <es@m-labs.hk>
Fix signal blocker argument -atse
2024-05-08 14:49:03 +08:00
44ef2c04e3
Fix bugs, grammar, text, and refactor into class
2024-05-08 14:49:03 +08:00
400f3a98e8
Stop polling drift
...
Just waiting for the update_s doesn't take into account the time to
execute update_params, and causes time drift.
2024-05-08 14:49:03 +08:00
7dd5d15047
Remove unused 'as' clause
2024-05-08 14:49:03 +08:00
65e1f4a146
Finish moving over to qasync
...
Also:
* Add aioclient
The old client is synchronous and blocking, and the only way to achieve
true asynchronous IO is to create a new client that interfaces with
asyncio.
* Finish Nix Flake description and make the GUI available for `nix run`
2024-05-08 14:49:03 +08:00
e0ce14c616
Try move from Qthreads to qasync
...
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
a79679a074
Create client watcher, that would poll Thermostat for config
...
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00
b9acba69d3
Create basic GUI, that would connect and control thermostat's fan
...
Signed-off-by: Egor Savkin <es@m-labs.hk>
2024-05-08 14:49:03 +08:00