73
README.md
73
README.md
@ -94,42 +94,43 @@ The scope of this setting is per TCP session.
|
|||||||
Send commands as simple text string terminated by `\n`. Responses are
|
Send commands as simple text string terminated by `\n`. Responses are
|
||||||
formatted as line-delimited JSON.
|
formatted as line-delimited JSON.
|
||||||
|
|
||||||
| Syntax | Function |
|
| Syntax | Function |
|
||||||
|----------------------------------|-------------------------------------------------------------------------------|
|
|-------------------------------------------|-------------------------------------------------------------------------------|
|
||||||
| `report` | Show current input |
|
| `report` | Show current input |
|
||||||
| `report mode` | Show current report mode |
|
| `report mode` | Show current report mode |
|
||||||
| `report mode <off/on>` | Set report mode |
|
| `report mode <off/on>` | Set report mode |
|
||||||
| `pwm` | Show current PWM settings |
|
| `pwm` | Show current PWM settings |
|
||||||
| `pwm <0/1> max_i_pos <amp>` | Set maximum positive output current |
|
| `pwm <0/1> max_i_pos <amp>` | Set maximum positive output current |
|
||||||
| `pwm <0/1> max_i_neg <amp>` | Set maximum negative output current |
|
| `pwm <0/1> max_i_neg <amp>` | Set maximum negative output current |
|
||||||
| `pwm <0/1> max_v <volt>` | Set maximum output voltage |
|
| `pwm <0/1> max_v <volt>` | Set maximum output voltage |
|
||||||
| `pwm <0/1> i_set <amp>` | Disengage PID, set fixed output current |
|
| `pwm <0/1> i_set <amp>` | Disengage PID, set fixed output current |
|
||||||
| `pwm <0/1> pid` | Let output current to be controlled by the PID |
|
| `pwm <0/1> polarity_swapped <false/true>` | Swap output current polarity on channel |
|
||||||
| `center <0/1> <volt>` | Set the MAX1968 0A-centerpoint to the specified fixed voltage |
|
| `pwm <0/1> pid` | Let output current to be controlled by the PID |
|
||||||
| `center <0/1> vref` | Set the MAX1968 0A-centerpoint to measure from VREF |
|
| `center <0/1> <volt>` | Set the MAX1968 0A-centerpoint to the specified fixed voltage |
|
||||||
| `pid` | Show PID configuration |
|
| `center <0/1> vref` | Set the MAX1968 0A-centerpoint to measure from VREF |
|
||||||
| `pid <0/1> target <deg_celsius>` | Set the PID controller target temperature |
|
| `pid` | Show PID configuration |
|
||||||
| `pid <0/1> kp <value>` | Set proportional gain |
|
| `pid <0/1> target <deg_celsius>` | Set the PID controller target temperature |
|
||||||
| `pid <0/1> ki <value>` | Set integral gain |
|
| `pid <0/1> kp <value>` | Set proportional gain |
|
||||||
| `pid <0/1> kd <value>` | Set differential gain |
|
| `pid <0/1> ki <value>` | Set integral gain |
|
||||||
| `pid <0/1> output_min <amp>` | Set mininum output |
|
| `pid <0/1> kd <value>` | Set differential gain |
|
||||||
| `pid <0/1> output_max <amp>` | Set maximum output |
|
| `pid <0/1> output_min <amp>` | Set mininum output |
|
||||||
| `s-h` | Show Steinhart-Hart equation parameters |
|
| `pid <0/1> output_max <amp>` | Set maximum output |
|
||||||
| `s-h <0/1> <t0/b/r0> <value>` | Set Steinhart-Hart parameter for a channel |
|
| `s-h` | Show Steinhart-Hart equation parameters |
|
||||||
| `postfilter` | Show postfilter settings |
|
| `s-h <0/1> <t0/b/r0> <value>` | Set Steinhart-Hart parameter for a channel |
|
||||||
| `postfilter <0/1> off` | Disable postfilter |
|
| `postfilter` | Show postfilter settings |
|
||||||
| `postfilter <0/1> rate <rate>` | Set postfilter output data rate |
|
| `postfilter <0/1> off` | Disable postfilter |
|
||||||
| `load [0/1]` | Restore configuration for channel all/0/1 from flash |
|
| `postfilter <0/1> rate <rate>` | Set postfilter output data rate |
|
||||||
| `save [0/1]` | Save configuration for channel all/0/1 to flash |
|
| `load [0/1]` | Restore configuration for channel all/0/1 from flash |
|
||||||
| `reset` | Reset the device |
|
| `save [0/1]` | Save configuration for channel all/0/1 to flash |
|
||||||
| `dfu` | Reset device and enters USB device firmware update (DFU) mode |
|
| `reset` | Reset the device |
|
||||||
| `ipv4 <X.X.X.X/L> [Y.Y.Y.Y]` | Configure IPv4 address, netmask length, and optional default gateway |
|
| `dfu` | Reset device and enters USB device firmware update (DFU) mode |
|
||||||
| `fan` | Show current fan settings and sensors' measurements |
|
| `ipv4 <X.X.X.X/L> [Y.Y.Y.Y]` | Configure IPv4 address, netmask length, and optional default gateway |
|
||||||
| `fan <value>` | Set fan power with values from 1 to 100 |
|
| `fan` | Show current fan settings and sensors' measurements |
|
||||||
| `fan auto` | Enable automatic fan speed control |
|
| `fan <value>` | Set fan power with values from 1 to 100 |
|
||||||
| `fcurve <a> <b> <c>` | Set fan controller curve coefficients (see *Fan control* section) |
|
| `fan auto` | Enable automatic fan speed control |
|
||||||
| `fcurve default` | Set fan controller curve coefficients to defaults (see *Fan control* section) |
|
| `fcurve <a> <b> <c>` | Set fan controller curve coefficients (see *Fan control* section) |
|
||||||
| `hwrev` | Show hardware revision, and settings related to it |
|
| `fcurve default` | Set fan controller curve coefficients to defaults (see *Fan control* section) |
|
||||||
|
| `hwrev` | Show hardware revision, and settings related to it |
|
||||||
|
|
||||||
|
|
||||||