@ -239,6 +239,20 @@ of channel 0 to the PID algorithm:
|
||||
output 0 pid
|
||||
```
|
||||
|
||||
### PID output clamping
|
||||
|
||||
It is possible to clamp the PID algorithm output independently of channel output limits. This is desirable when e.g. there is a need to keep the current value above a certain threshold in closed-loop mode.
|
||||
|
||||
Set PID maximum output of channel 0 to 1.5 A.
|
||||
```
|
||||
pid 0 output_max 1.5
|
||||
```
|
||||
|
||||
Set PID minimum output of channel 0 to 0.1 A.
|
||||
```
|
||||
pid 0 output_min 0.1
|
||||
```
|
||||
|
||||