## Thermo-Electric Cooling (TEC)
|
## Thermo-Electric Cooling (TEC)
|
||||||
|
|
||||||
|
Connect the Peltier device to the TEC0/1-/+ outputs.
|
||||||
|
|
||||||
### Limits
|
### Limits
|
||||||
|
|
||||||
Each of the MAX1968 TEC driver has analog/PWM inputs for setting
|
Each of the MAX1968 TEC driver has analog/PWM inputs for setting
|
||||||
@ -127,7 +129,7 @@ Use the `pwm` command to see current settings and maximum values.
|
|||||||
| `max_v` | Volts | Maximum voltage |
|
| `max_v` | Volts | Maximum voltage |
|
||||||
| `max_i_pos` | Amperes | Maximum positive current |
|
| `max_i_pos` | Amperes | Maximum positive current |
|
||||||
| `max_i_neg` | Amperes | Maximum negative current |
|
| `max_i_neg` | Amperes | Maximum negative current |
|
||||||
| | Amperes | current control |
|
| | Amperes | Output current control |
|
||||||
|
|
||||||
Example: set the maximum voltage of channel 0 to 1.5 V.
|
Example: set the maximum voltage of channel 0 to 1.5 V.
|
||||||
```
|
```
|
||||||
@ -158,6 +160,14 @@ of channel 0 to the PID algorithm:
|
|||||||
pwm 0 pid
|
pwm 0 pid
|
||||||
```
|
```
|
||||||
|
|
||||||
|
## LED indicators
|
||||||
|
|
||||||
|
| Name | Color | Meaning |
|
||||||
|
| --- | :---: | --- |
|
||||||
|
| R1 | Red | Firmware initializing |
|
||||||
|
| G3 | Green | Closed-loop mode (PID engaged) |
|
||||||
|
| G4 | Green | Firmware busy |
|
||||||
|
|
||||||
## Reports
|
## Reports
|
||||||
|
|
||||||
Use the bare `report` command to obtain a single report. Enable
|
Use the bare `report` command to obtain a single report. Enable
|
||||||
|