@ -98,10 +98,10 @@ formatted as line-delimited JSON.
|
|||||||
| `report mode` | Show current report mode |
|
| `report mode` | Show current report mode |
|
||||||
| `report mode <off/on>` | Set report mode |
|
| `report mode <off/on>` | Set report mode |
|
||||||
| `pwm` | Show current PWM settings |
|
| `pwm` | Show current PWM settings |
|
||||||
| `pwm <0/1> max_i_pos <amp>` | Set maximum positive output current |
|
| `pwm <0/1> max_i_pos <amp>` | Set maximum positive output current, clamped to [0, 2] |
|
||||||
| `pwm <0/1> max_i_neg <amp>` | Set maximum negative output current |
|
| `pwm <0/1> max_i_neg <amp>` | Set maximum negative output current, clamped to [0, 2] |
|
||||||
| `pwm <0/1> max_v <volt>` | Set maximum output voltage |
|
| `pwm <0/1> max_v <volt>` | Set maximum output voltage, clamped to [0, 4] |
|
||||||
| `pwm <0/1> i_set <amp>` | Disengage PID, set fixed output current |
|
| `pwm <0/1> i_set <amp>` | Disengage PID, set fixed output current, clamped to [-2, 2] |
|
||||||
| `pwm <0/1> polarity <normal/reversed>` | Set output current polarity, with 'normal' being the front panel polarity |
|
| `pwm <0/1> polarity <normal/reversed>` | Set output current polarity, with 'normal' being the front panel polarity |
|
||||||
| `pwm <0/1> pid` | Let output current to be controlled by the PID |
|
| `pwm <0/1> pid` | Let output current to be controlled by the PID |
|
||||||
| `center <0/1> <volt>` | Set the MAX1968 0A-centerpoint to the specified fixed voltage |
|
| `center <0/1> <volt>` | Set the MAX1968 0A-centerpoint to the specified fixed voltage |
|
||||||
|