SUServo (Sampler + Urukul)
JSON
{
"type": "suservo",
"sampler_ports": [<port num>, <port num>],
"urukul0_ports": [<port num>, <port num>],
"urukul1_ports": [<port num>, <port num>], // optional
"clk_sel": 2
}
With enabled SUServo mode, you only need to add suservo
to JSON file, with its Sampler and Urukul(s) removed.
Setup
On bottoms of each Urukul, switch first pins 1 and 2 to ON
, as on the picture:
Testing
After running artiq_sinara_test
:
*** Testing SUServos.
Initializing modules...
suservo0
...done
Setting up SUServo channels...
suservo0_ch0
suservo0_ch1
suservo0_ch2
suservo0_ch3
suservo0_ch4
suservo0_ch5
suservo0_ch6
suservo0_ch7
...done
Enabling...
suservo0
...done
Each Sampler channel applies proportional amplitude control
on the respective Urukul0 (ADC 0-3) and Urukul1 (ADC 4-7, if
present) channels.
Frequency: 10 MHz, output power: about -9 dBm at 0 V and about -15 dBm at 1.5 V
Verify frequency and power behavior.
- Connect oscilloscope to the
urukul0
port and configure with time and voltage scale and trigger threshold so that you'll see sine wave, like on the picture: - Verify amplitude and frequency
- Apply 1.5V (connect the AA-battery) to the
sampler0
port, as on the picture: - You should see significant amplitude decrease, as in the picture:
- Verify amplitude difference, and the frequency to be unchanged
- Repeat steps 1-5 for every available channel.