Support fan PWM settings #73
@ -54,7 +54,9 @@ impl FanCtrl {
|
||||
FanCtrl {
|
||||
fan,
|
||||
available,
|
||||
fan_auto: true,
|
||||
// do not enable auto mode by default,
|
||||
// but allow to turn it on on customer's own risk
|
||||
|
||||
fan_auto: hwrev.fan_auto_mode_available(),
|
||||
k_a: DEFAULT_K_A,
|
||||
k_b: DEFAULT_K_B,
|
||||
k_c: DEFAULT_K_C,
|
||||
@ -142,6 +144,12 @@ impl HWRev {
|
||||
pub fn fan_available(&self) -> bool {
|
||||
self.major == 2 && self.minor == 2
|
||||
}
|
||||
|
||||
pub fn fan_auto_mode_available(&self) -> bool {
|
||||
sb10q
commented
This poorly chosen name suggests that auto mode is not available at all. Rename to fan_default_auto or similar. This poorly chosen name suggests that auto mode is not available at all.
Rename to fan_default_auto or similar.
|
||||
// see https://github.com/sinara-hw/Thermostat/issues/115 and
|
||||
// https://git.m-labs.hk/M-Labs/thermostat/issues/69#issuecomment-6464 for explanation
|
||||
self.fan_available() && self.minor != 2
|
||||
}
|
||||
}
|
||||
|
||||
#[derive(Serialize)]
|
||||
|
Loading…
Reference in New Issue
Block a user
at user's own risk