README: Fix limits section #154
13
README.md
13
README.md
@ -189,31 +189,30 @@ Testing heat flow direction with a low set current is recommended before install
|
||||
|
||||
### Limits
|
||||
|
||||
Each MAX1968 TEC driver has analog/PWM inputs for setting
|
||||
Each channel has maximum value settings, for setting
|
||||
output limits.
|
||||
|
||||
Use the `output` command to see current settings and maximum values.
|
||||
Use the `output` command to see them.
|
||||
|
||||
| Limit | Unit | Description |
|
||||
| --- | :---: | --- |
|
||||
| `max_v` | Volts | Maximum voltage |
|
||||
| `max_i_pos` | Amperes | Maximum positive current |
|
||||
| `max_i_neg` | Amperes | Maximum negative current |
|
||||
| `i_set` | Amperes | (Not a limit; Open-loop mode) |
|
||||
|
||||
Example: set the maximum voltage of channel 0 to 1.5 V.
|
||||
```
|
||||
output 0 max_v 1.5
|
||||
```
|
||||
|
||||
Example: set the maximum negative current of channel 0 to -3 A.
|
||||
Example: set the maximum negative current of channel 0 to -2 A.
|
||||
```
|
||||
output 0 max_i_neg 3
|
||||
output 0 max_i_neg 2
|
||||
```
|
||||
|
||||
Example: set the maximum positive current of channel 1 to 3 A.
|
||||
Example: set the maximum positive current of channel 1 to 2 A.
|
||||
```
|
||||
output 0 max_i_pos 3
|
||||
output 1 max_i_pos 2
|
||||
```
|
||||
|
||||
### Open-loop mode
|
||||
|
Loading…
Reference in New Issue
Block a user