mirror of
https://github.com/m-labs/artiq.git
synced 2024-12-25 11:18:27 +08:00
157 lines
5.0 KiB
ReStructuredText
157 lines
5.0 KiB
ReStructuredText
.. Add new releases at the top to keep important stuff directly visible.
|
|
|
|
Release notes
|
|
=============
|
|
|
|
3.0 (unreleased)
|
|
----------------
|
|
|
|
* The --embed option of applets is replaced with the environment variable
|
|
ARTIQ_APPLET_EMBED. The GUI sets this enviroment variable itself and the
|
|
user simply needs to remove the --embed argument.
|
|
* EnvExperiment's prepare calls prepare for all its children.
|
|
* Dynamic __getattr__'s returning RPC target methods are not supported anymore.
|
|
Controller driver classes must define all their methods intended for RPC as
|
|
members.
|
|
* Datasets requested by experiments are by default archived into their HDF5
|
|
output. If this behavior is undesirable, turn it off by passing
|
|
``archive=False`` to ``get_dataset``.
|
|
|
|
|
|
2.0
|
|
---
|
|
|
|
No further notes.
|
|
|
|
|
|
2.0rc2
|
|
------
|
|
|
|
No further notes.
|
|
|
|
|
|
2.0rc1
|
|
------
|
|
|
|
* The format of the influxdb pattern file is simplified. The procedure to
|
|
edit patterns is also changed to modifying the pattern file and calling:
|
|
``artiq_rpctool.py ::1 3248 call scan_patterns`` (or restarting the bridge)
|
|
The patterns can be converted to the new format using this code snippet::
|
|
|
|
from artiq.protocols import pyon
|
|
patterns = pyon.load_file("influxdb_patterns.pyon")
|
|
for p in patterns:
|
|
print(p)
|
|
|
|
* The "GUI" has been renamed the "dashboard".
|
|
* When flashing NIST boards, use "-m nist_qcX" or "-m nist_clock" instead of
|
|
just "-m qcX" or "-m clock" (#290).
|
|
* Applet command lines now use templates (e.g. $python) instead of formats
|
|
(e.g. {python}).
|
|
* On Windows, GUI applications no longer open a console. For debugging
|
|
purposes, the console messages can still be displayed by running the GUI
|
|
applications this way::
|
|
|
|
python3.5 -m artiq.frontend.artiq_browser
|
|
python3.5 -m artiq.frontend.artiq_dashboard
|
|
|
|
(you may need to replace python3.5 with python)
|
|
Please always include the console output when reporting a GUI crash.
|
|
* The result folders are formatted "%Y-%m-%d/%H instead of "%Y-%m-%d/%H-%M".
|
|
(i.e. grouping by day and then by hour, instead of by day and then by minute)
|
|
* The ``parent`` keyword argument of ``HasEnvironment`` (and ``EnvExperiment``)
|
|
has been replaced. Pass the parent as first argument instead.
|
|
* During experiment examination (and a fortiori repository scan), the values of
|
|
all arguments are set to ``None`` regardless of any default values supplied.
|
|
* In the dashboard's experiment windows, partial or full argument recomputation
|
|
takes into account the repository revision field.
|
|
* By default, ``NumberValue`` and ``Scannable`` infer the scale from the unit
|
|
for common units.
|
|
* By default, artiq_client keeps the current persist flag on the master.
|
|
* GUI state files for the browser and the dashboard are stores in "standard"
|
|
locations for each operating system. Those are
|
|
``~/.config/artiq/2/artiq_*.pyon`` on Linux and
|
|
``C:\Users\<username>\AppData\Local\m-labs\artiq\2\artiq_*.pyon`` on
|
|
Windows 7.
|
|
* The position of the time cursor is kept across experiments and RTIO resets
|
|
are manual and explicit (inter-experiment seamless handover).
|
|
* All integers manipulated by kernels are numpy integers (numpy.int32,
|
|
numpy.int64). If you pass an integer as a RPC argument, the target function
|
|
receives a numpy type.
|
|
|
|
|
|
1.3
|
|
---
|
|
|
|
No further notes.
|
|
|
|
|
|
1.2
|
|
---
|
|
|
|
No further notes.
|
|
|
|
|
|
1.1
|
|
---
|
|
|
|
* TCA6424A.set converts the "outputs" value to little-endian before programming
|
|
it into the registers.
|
|
|
|
|
|
1.0
|
|
---
|
|
|
|
No further notes.
|
|
|
|
|
|
1.0rc4
|
|
------
|
|
|
|
* setattr_argument and setattr_device add their key to kernel_invariants.
|
|
|
|
|
|
1.0rc3
|
|
------
|
|
|
|
* The HDF5 format has changed.
|
|
|
|
* The datasets are located in the HDF5 subgroup ``datasets``.
|
|
* Datasets are now stored without additional type conversions and annotations
|
|
from ARTIQ, trusting that h5py maps and converts types between HDF5 and
|
|
python/numpy "as expected".
|
|
|
|
* NumberValue now returns an integer if ``ndecimals`` = 0, ``scale`` = 1 and
|
|
``step`` is integer.
|
|
|
|
|
|
1.0rc2
|
|
------
|
|
|
|
* The CPU speed in the pipistrello gateware has been reduced from 83 1/3 MHz to
|
|
75 MHz. This will reduce the achievable sustained pulse rate and latency
|
|
accordingly. ISE was intermittently failing to meet timing (#341).
|
|
* set_dataset in broadcast mode no longer returns a Notifier. Mutating datasets
|
|
should be done with mutate_dataset instead (#345).
|
|
|
|
|
|
1.0rc1
|
|
------
|
|
|
|
* Experiments (your code) should use ``from artiq.experiment import *``
|
|
(and not ``from artiq import *`` as previously)
|
|
* Core device flash storage has moved due to increased runtime size.
|
|
This requires reflashing the runtime and the flash storage filesystem image
|
|
or erase and rewrite its entries.
|
|
* ``RTIOCollisionError`` has been renamed to ``RTIOCollision``
|
|
* the new API for DDS batches is::
|
|
|
|
with self.core_dds.batch:
|
|
...
|
|
|
|
with ``core_dds`` a device of type ``artiq.coredevice.dds.CoreDDS``.
|
|
The dds_bus device should not be used anymore.
|
|
* LinearScan now supports scanning from high to low. Accordingly,
|
|
its arguments ``min/max`` have been renamed to ``start/stop`` respectively.
|
|
Same for RandomScan (even though there direction matters little).
|