# This is an example device database that needs to be adapted to your setup.
# The RTIO channel numbers here are for NIST QC1 on KC705.
{
"comm": {
"type": "local",
"module": "artiq.coredevice.comm_tcp",
"class": "Comm",
"arguments": {"host": "192.168.0.42"}
},
"core": {
"type": "local",
"module": "artiq.coredevice.core",
"class": "Core",
"arguments": {"ref_period": 1e-9}
},
"pmt0": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLInOut",
"arguments": {"channel": 0}
},
"pmt1": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLInOut",
"arguments": {"channel": 1}
},
"ttl0": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLOut",
"arguments": {"channel": 2},
"comment": "This is a fairly long comment to test word wrapping in GUI."
},
"ttl1": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLOut",
"arguments": {"channel": 3},
"comment": "Hello World"
},
"ttl2": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLOut",
"arguments": {"channel": 4}
},
"ttl3": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLOut",
"arguments": {"channel": 5}
},
"ttl4": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLOut",
"arguments": {"channel": 6}
},
"ttl5": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLOut",
"arguments": {"channel": 7}
},
"ttl_sma": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLInOut",
"arguments": {"channel": 17}
},
"led": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLOut",
"arguments": {"channel": 18}
},
"ttl15": {
"type": "local",
"module": "artiq.coredevice.ttl",
"class": "TTLClockGen",
"arguments": {"channel": 19}
},
"dds_bus": {
"type": "local",
"module": "artiq.coredevice.dds",
"class": "DDSBus",
"arguments": {}
},
"dds0": {
"type": "local",
"module": "artiq.coredevice.dds",
"class": "AD9858",
"arguments": {"sysclk": 1e9, "channel": 0},
"comment": "Comments work in DDS panel as well"
},
"dds1": {
"type": "local",
"module": "artiq.coredevice.dds",
"class": "AD9858",
"arguments": {"sysclk": 1e9, "channel": 1}
},
"dds2": {
"type": "local",
"module": "artiq.coredevice.dds",
"class": "AD9858",
"arguments": {"sysclk": 1e9, "channel": 2}
},
"qc_q1_0": {
"type": "controller",
# ::1 is the IPv6 localhost address. If this controller is running on a remote machine,
# replace it with the IP or hostname of the machine. If using the hostname, make sure
# that it always resolves to a network-visible IP address (see documentation).
"host": "::1",
"port": 4000,
"command": "pdq2_controller --no-localhost-bind -p {port} --bind {bind} --simulation --dump qc_q1_0.bin"
},
"qc_q1_1": {
"type": "controller",
"host": "::1",
"port": 4001,
"command": "pdq2_controller --no-localhost-bind -p {port} --bind {bind} --simulation --dump qc_q1_1.bin"
},
"qc_q1_2": {
"type": "controller",
"host": "::1",
"port": 4002,
"command": "pdq2_controller --no-localhost-bind -p {port} --bind {bind} --simulation --dump qc_q1_2.bin"
},
"qc_q1_3": {
"type": "controller",
"host": "::1",
"port": 4003,
"command": "pdq2_controller --no-localhost-bind -p {port} --bind {bind} --simulation --dump qc_q1_3.bin"
},
"electrodes": {
"type": "local",
"module": "artiq.devices.pdq2",
"class": "CompoundPDQ2",
"arguments": {
"pdq2_devices": ["qc_q1_0", "qc_q1_1", "qc_q1_2", "qc_q1_3"],
"trigger_device": "ttl2",
"frame_devices": ["ttl3", "ttl4", "ttl5"]
}
},
"lda": {
"type": "controller",
"best_effort": true,
"host": "::1",
"port": 3253,
"command": "lda_controller -p {port} --bind {bind} --simulation"
},
"ttl_out": "ttl0",
"ttl_out_serdes": "ttl0",
"pmt": "pmt0",
"bd_dds": "dds0",
"bd_sw": "ttl0",
"bdd_dds": "dds1",
"bdd_sw": "ttl1"
}