artiq/artiq/frontend/artiq_devtool.py

216 lines
8.7 KiB
Python
Executable File

#!/usr/bin/env python3
# This script makes the following assumptions:
# * miniconda is installed remotely at ~/miniconda
# * misoc and artiq are installed remotely via conda
import sys
import argparse
import logging
import subprocess
import socket
import select
import threading
import os
import shutil
from artiq.tools import verbosity_args, init_logger, logger, SSHClient
def get_argparser():
parser = argparse.ArgumentParser(description="ARTIQ core device development tool")
verbosity_args(parser)
parser.add_argument("-H", "--host", metavar="HOSTNAME",
type=str, default="lab.m-labs.hk",
help="SSH host where the development board is located")
parser.add_argument("-D", "--device", metavar="HOSTNAME",
type=str, default="kc705.lab.m-labs.hk",
help="address or domain corresponding to the development board")
parser.add_argument("-s", "--serial", metavar="PATH",
type=str, default="/dev/ttyUSB_kc705",
help="TTY device corresponding to the development board")
parser.add_argument("-l", "--lockfile", metavar="PATH",
type=str, default="/run/boards/kc705",
help="The lockfile to be acquired for the duration of the actions")
parser.add_argument("-w", "--wait", action="store_true",
help="Wait for the board to unlock instead of aborting the actions")
parser.add_argument("-t", "--target", metavar="TARGET",
type=str, default="kc705_dds",
help="Target to build, one of: "
"kc705_dds kasli sayma_amc_standalone "
"sayma_amc_drtio_master sayma_amc_drtio_satellite")
parser.add_argument("actions", metavar="ACTION",
type=str, default=[], nargs="+",
help="actions to perform, sequence of: "
"build boot boot+log connect reset hotswap clean")
return parser
def main():
args = get_argparser().parse_args()
init_logger(args)
if args.verbose == args.quiet == 0:
logging.getLogger().setLevel(logging.INFO)
if args.target in ["kc705_dds", "kasli", "sayma_amc_standalone", "sayma_amc_drtio_master"]:
firmware = "runtime"
elif args.target == "sayma_amc_drtio_satellite":
firmware = "satman"
else:
raise NotImplementedError("unknown target {}".format(args.target))
client = SSHClient(args.host)
substs = {
"env": "bash -c 'export PATH=$HOME/miniconda/bin:$PATH; exec $0 $*' ",
"serial": args.serial,
"firmware": firmware,
}
flock_acquired = False
flock_file = None # GC root
def lock():
nonlocal flock_acquired
nonlocal flock_file
if not flock_acquired:
logger.info("Acquiring device lock")
flock = client.spawn_command("flock --verbose {block} {lockfile} sleep 86400"
.format(block="" if args.wait else "--nonblock",
lockfile=args.lockfile),
get_pty=True)
flock_file = flock.makefile('r')
while not flock_acquired:
line = flock_file.readline()
if not line:
break
logger.debug(line.rstrip())
if line.startswith("flock: executing"):
flock_acquired = True
elif line.startswith("flock: failed"):
logger.error("Failed to get lock")
sys.exit(1)
for action in args.actions:
if action == "build":
logger.info("Building firmware")
try:
subprocess.check_call(["python3",
"-m", "artiq.gateware.targets." + args.target,
"--no-compile-gateware",
"--output-dir",
"/tmp/{target}".format(target=args.target)])
except subprocess.CalledProcessError:
logger.error("Build failed")
sys.exit(1)
elif action == "clean":
logger.info("Cleaning build directory")
target_dir = "/tmp/{target}".format(target=args.target)
if os.path.isdir(target_dir):
shutil.rmtree(target_dir)
elif action == "boot" or action == "boot+log":
lock()
logger.info("Uploading firmware")
client.get_sftp().put("/tmp/{target}/software/{firmware}/{firmware}.bin"
.format(target=args.target, firmware=firmware),
"{tmp}/{firmware}.bin"
.format(tmp=client.tmp, firmware=firmware))
logger.info("Booting firmware")
flterm = client.spawn_command(
"{env} python3 flterm.py {serial} " +
"--kernel {tmp}/{firmware}.bin " +
("--upload-only" if action == "boot" else "--output-only"),
**substs)
artiq_flash = client.spawn_command(
"{env} artiq_flash start",
**substs)
client.drain(flterm)
elif action == "connect":
lock()
transport = client.get_transport()
transport.set_keepalive(30)
def forwarder(local_stream, remote_stream):
try:
while True:
r, _, _ = select.select([local_stream, remote_stream], [], [])
if local_stream in r:
data = local_stream.recv(65535)
if data == b"":
break
remote_stream.sendall(data)
if remote_stream in r:
data = remote_stream.recv(65535)
if data == b"":
break
local_stream.sendall(data)
except Exception as err:
logger.error("Cannot forward on port %s: %s", port, repr(err))
local_stream.close()
remote_stream.close()
def listener(port):
listener = socket.socket()
listener.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
listener.bind(('localhost', port))
listener.listen(8)
while True:
local_stream, peer_addr = listener.accept()
logger.info("Accepting %s:%s and opening SSH channel to %s:%s",
*peer_addr, args.device, port)
try:
remote_stream = \
transport.open_channel('direct-tcpip', (args.device, port), peer_addr)
except Exception:
logger.exception("Cannot open channel on port %s", port)
continue
thread = threading.Thread(target=forwarder, args=(local_stream, remote_stream),
name="forward-{}".format(port), daemon=True)
thread.start()
ports = [1380, 1381, 1382, 1383]
for port in ports:
thread = threading.Thread(target=listener, args=(port,),
name="listen-{}".format(port), daemon=True)
thread.start()
logger.info("Forwarding ports {} to core device and logs from core device"
.format(", ".join(map(str, ports))))
client.run_command(
"{env} python3 flterm.py {serial} --output-only",
**substs)
elif action == "reset":
logger.info("Resetting device")
client.run_command(
"{env} artiq_flash start",
**substs)
elif action == "hotswap":
logger.info("Hotswapping firmware")
try:
subprocess.check_call(["python3",
"-m", "artiq.frontend.artiq_coreboot", "hotswap",
"/tmp/{target}/software/{firmware}/{firmware}.bin"
.format(target=args.target, firmware=firmware)])
except subprocess.CalledProcessError:
logger.error("Build failed")
sys.exit(1)
else:
logger.error("Unknown action {}".format(action))
sys.exit(1)
if __name__ == "__main__":
main()