mirror of https://github.com/m-labs/artiq.git
dds: do not reset AD9914
This commit is contained in:
parent
d621780206
commit
eb554f86f9
|
@ -18,7 +18,7 @@
|
||||||
/* DAC calibration takes max. 1ms as per datasheet */
|
/* DAC calibration takes max. 1ms as per datasheet */
|
||||||
#define DURATION_DAC_CAL (147000 << RTIO_FINE_TS_WIDTH)
|
#define DURATION_DAC_CAL (147000 << RTIO_FINE_TS_WIDTH)
|
||||||
/* not counting final FUD */
|
/* not counting final FUD */
|
||||||
#define DURATION_INIT (10*DURATION_WRITE + DURATION_DAC_CAL)
|
#define DURATION_INIT (8*DURATION_WRITE + DURATION_DAC_CAL)
|
||||||
#define DURATION_PROGRAM (6*DURATION_WRITE) /* not counting FUD */
|
#define DURATION_PROGRAM (6*DURATION_WRITE) /* not counting FUD */
|
||||||
|
|
||||||
#else
|
#else
|
||||||
|
@ -59,8 +59,17 @@ void dds_init(long long int timestamp, int channel)
|
||||||
#endif
|
#endif
|
||||||
channel <<= 1;
|
channel <<= 1;
|
||||||
DDS_WRITE(DDS_GPIO, channel);
|
DDS_WRITE(DDS_GPIO, channel);
|
||||||
|
#ifndef DDS_AD9914
|
||||||
|
/*
|
||||||
|
* Resetting a AD9914 intermittently crashes it. It does not produce any
|
||||||
|
* output until power-cycled.
|
||||||
|
* Increasing the reset pulse length and the delay until the first write
|
||||||
|
* to 300ns do not solve the problem.
|
||||||
|
* The chips seem fine without a reset.
|
||||||
|
*/
|
||||||
DDS_WRITE(DDS_GPIO, channel | 1); /* reset */
|
DDS_WRITE(DDS_GPIO, channel | 1); /* reset */
|
||||||
DDS_WRITE(DDS_GPIO, channel);
|
DDS_WRITE(DDS_GPIO, channel);
|
||||||
|
#endif
|
||||||
|
|
||||||
#ifdef DDS_AD9858
|
#ifdef DDS_AD9858
|
||||||
/*
|
/*
|
||||||
|
|
Loading…
Reference in New Issue